4XLFN6WDUW*XLGH
Introduction
This Quick Start Guide can help you install the ReadyGuard quickly and easily by providing the
basic steps for installation using the built-in defaults. For more detailed information and important
notes, refer to the ReadyGuard Installation Instructions.
The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default
tables, see the Installation Instructions.
Default Table Summary
Zone Table 1 Table 2 Table 3 Table 4 Table 5
1 ------- ------- ------- ------- -------
2 front door front door front door front door front door
3 back door back door back door back door back door
4 window window window window window
5 motion detector motion detector window window motion detector
6 ------- smoke detector window window -------
7 ------- ------- window window -------
8 ------- ------- motion detector motion detector -------
9 ------- ------- smoke detector smoke detector -------
26 loop 3 arm away ‡‡‡‡
27 loop 2 disarm ‡‡‡‡
28 loop 4 close device 1 ‡‡‡‡
29 loop 1 restore device 1 ‡‡‡‡
30 loop 3 arm away ‡‡‡‡
31 loop 2 disarm ‡‡‡‡
32 loop 4 close device 1 ‡‡‡‡
33 loop 1 restore device 1 ‡‡‡‡
92 duress duress duress duress duress
99 silent alarm silent alarm silent alarm silent alarm silent alarm
User 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4
Code
Install 4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2
Code
‡ zones 26 – 33 are button zones and programmed the same as in Table 1.
Entering Program Mode: installer code + 8 0 0
Interactive Mode Used to Program
*56 Zone Programming Zone characteristics, report codes, and serial numbers
*83 Sequential Mode 5800 Series transmitter serial numbers
*84 Assign Zone Voice Descriptors Voice descriptors for each zone
Exiting Program Mode
*99 allows re-entry into the Program mode using Installer Code + 8 0 0.
*98 inhibits re-entry into the Programming mode using the Installer Code.
NOTES:
•Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone
number), and a Powerline Carrier Device programmed as device 8, which closes and stays closed upon
burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a pulsing
siren), see the *80 Powerline Carrier Device Programming section of the Installation Instructions.
•Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use Contact ID
for secondary reporting. Tables 1, 3, and 5 use 4+1 format for secondary reporting.
•Tables 1 and 5 record all events in the event log. Tables 2, 3, and 4 record only alarms, alarm restores,
troubles, and trouble restores in their event logs.
Page 2
Steps to Installing ReadyGuard
1. Separate the front assembly from the back plate and mount the back plate.
DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the front
assembly board.
2. Make wiring connections as follows:
Connect the incoming phone line to either the 8-position jack or terminals 2 (TIP) and 3 (RING).
Connect the handset phone lines to either the RJ11 jack or terminals 4 (TIP) and 5 (RING).
NOTE: For full line seize operation, see the installation instructions.
If used, connect a piezo sounder to terminals 10 (+) and 11 (–).
If used, connect a bell to terminals 11 (–) and 12 (+).
If using Powerline Carrier Devices, connect com/data/sync/ lines from the PL513 Powerline Interface
Module to terminals 9, 13, and 14 respectively.
Install Powerline Carrier Devices according to their instructions.
Connect wires from the 1332 (1332CN) AC Transformer to terminals 15 and 16.
3. After all wiring connections are made, carefully reconnect the ribbon cable to the front assembly
PC board connector (properly aligning the red wire), then snap the front assembly to the back plate so it
is held by the locking tabs.
Plug the transformer into a 24-hour, 110VAC unswitched outlet.
Slide out the battery drawer and install either a single 9V alkaline battery or six 1.5V “AA” alkaline
batteries. Use only nonrechargeable, alkaline batteries.
After installing the battery(ies), slide the battery drawer into the back plate only after AC power has
been applied.
4. Set a programming default:
Enter Programming mode: Installer Code + 8 0 0.
Press *97, then press a number 1-5 to select a default table from the tables listed on page 1.
5. Program the variable data fields:
Press *24 (RF House ID), then enter the desired 2-digit RF House ID for wireless keypads.
Press *40 (PABX Code, if used), then enter up to 6 digits. If fewer than 6 digits are used, press [*] to
end the field and advance to the next field.
Press *41 (Primary Phone Number), then enter the primary phone number, up to 20 digits. If fewer than
20 digits are used, press [*] to end the field and advance to the next field.
Press *42 (Secondary Phone Number) if used, then enter the secondary phone number, up to 24 digits.
If fewer than 24 digits are used, press [*] to end the field and advance to the next field.
Press *43 (Primary Account Number), then enter the primary account number. If only 3 digits are used,
press [*] to end the field and advance to the next field.
Press *44 (Secondary Account Number) if used, then enter the secondary account number. If only 3
digits are used, press [*] to end the field and advance to the next field.
Press *88 (Pager Characters) if using Default Table 2 or 4, then enter up to 16 digits which may be
required by your pager service (e.g. account number, PIN, etc.). If fewer than 16 digits are used, press
[*] to end the field and advance to the next field.
Press *94 (Download Phone Number), then enter the downloading computer phone number, up to 20
digits. If fewer than 20 digits are used, press [*] to end the field.
6. Enroll transmitter serial numbers by pressing *83 while in Programming mode, then follow the prompts:
% Enter the 2-digit zone number of the first transmitter whose serial number you are entering,
then press [*]. The system displays the “C” prompt.
' Enter the 7-digit serial number (printed on the transmitter). If you enter an incorrect digit,
press the [#] key to back up to that digit and reenter the correct digit. When all 7 digits are
entered, press the [*] key. Review the displayed serial number. If correct, press [*] again to
save it. The next zone number to be enrolled will display at the “C” prompt for 30 seconds. If
this is the desired zone number, enter its serial number as described above. If not, either
wait 30 seconds or press the [#] key to display the “b” prompt.
b  The system automatically displays the next zone number for which a serial number may be
enrolled. Press [1] to return to the “C” prompt described above to enroll this zone.
If the zone number displayed is not desired, press [0] to return to the “A” prompt, where you
can then enter a different zone number.
After all serial numbers have been enrolled, return to the “A” prompt, then enter [00] to exit enrollment
mode (blinking “83”). Press [*] + [99] to exit Program mode.
Page 3
7. Set RF House ID in the wireless keypads as follows:
If using a 5827 wireless keypad, set the keypad’s DIP switches to the RF House ID programmed in field
*24. If using a 5804BD button key or 5827BD keypad, set the RF House ID per its instructions.
If using Powerline Carrier Devices, set their House ID to “A,” (programmed as “0”) or use field *25 to
change the ID to avoid conflicts with existing installations.
8. Set the Real-Time Clock as follows:
Enter time/date setting mode by entering the Installer Code + [63].
The hour prompt is displayed. Enter the correct hour, then press [*] to accept and advance.
For each subsequent prompt, enter the correct value, then press [*].
You will exit this mode automatically after entering the year, or if no keys are pressed for 1 minute.
9. Test the system as follows:
After installation and programming, enter Installer Code + [5].
To exit Test mode, enter Installer Code + OFF.
10. Assign desired User Codes by following the procedures on the next page and in the User Guide.
Show the user how to perform the various system functions.
11. Perform site-initiated downloader session (to load central station ID) by Installer Code + [#] + [1].
BELL
6-14VDC
120mA max.
(e.g., WAVE2EX)
HANDSET
PHONE
LINE
}
INCOMING
PHONE
LINE
}
EARTH
GROUND
2k OHMS
EOLR
INCOMING
PHONE
LINE
TO HANDSET
PHONE
LINE
PIEZO
6-14VDC
30mA max.
HARD
WIRED
ZONE
123489
65 11
710 12 15 16
13 14
EARTH GROUND PHONE ZONE N/U SOUNDERS PLCD AC
9VAC
15VA TO 24HR 110VAC
UNSWITCHED
OUTLET
RJ11
8
POSITION
JACK
WARNING:
TO PREVENT
RISK OF
SHOCK,
DISCONNECT
TELEPHONE
LINE AT TELCO
JACK BEFORE
SERVICING
THIS UNIT.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWINGTWO
CONDITIONS: (1)THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
FCC ID: CFS8DLLYNX
CANADA: 17481021165A
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No.5GBUSA-25623-AL-E
RINGER EQUIVALENCE: 0.6B
THIS EQUIPMENT SHOULD BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL
FIRE PROTECTION ASSOCIATION’S STAN-
DARD 72, CHAPTER 2 (NATIONAL FIRE
PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED
INFORMATION DESCRIBING PROPER
INSTALLATION, OPERATION, TESTING,
MAINTENANCE, EVACUATION PLANNING
AND REPAIR SERVICE ISTO BE PROVIDED
WITH THIS EQUIPMENT.
PL513
POWERLINE INTERFACE
LOCAL SOUNDER
DISABLE JUMPER
CUT = DISABLE
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM.
ALL OUTPUT CIRCUITS
ARE POWER LIMITED.
TIP RING TIP RING (+) ( ) ( ) (+) ( ) (+) SYNC
IN
DATA
OUT
POWERLINE
CARRIER DEVICES
PLUG-IN
TRANSFORMER
(e.g., ADEMCO 1332)
CANADA USE 1332CN
NOTE: BACKUP BATTERY IS REQUIRED. USE
SINGLE 9V ALKALINE BATTERY (e.g., DURACELL
PC1604 PROCELL) OR SIX 1.5V ALKALINE “AA”
BATTERIES (e.g., DURACELL MN1500).
REPLACE BATTERY AT LEAST EVERYYEAR.
1 2 3 4
BLACK
YELLOW
RED
GREEN
4-WIRE MODULAR
PHONE CORD WITH
FLYING LEADS
ReadyGuard WIRING CONNECTIONS
5800 Series Transmitter Loop Numbers: The following illustration shows the compatible
transmitters and their associated input types and loop designations.
REDWIRE
MARKING
116
LOCKINGTABS
DISCONNECT
THIS END ONLY!
NOTE:
MAKE SURE BATTERY
CLIPS ENTER SLOTS
WHEN SNAPPING
FRONT ASSEMBLY
TO BACKPLATE
BATTERY CLIPS
5801
ENROLL AS "UR" OR "RF"
LOOP
1
5802/5802CP
ENROLL AS "BR"
LOOP
1
5802MN
ENROLL AS "UR" OR "RF"
LOOP
1
5806/5807/5808
(5806 SHOWN)
ENROLL AS "RF"
5817
ENROLL AS "RF"
LOOP
1
(PRIMARY)
2
(AUX. CENTER)
3
(AUX. RIGHT)
5818
ENROLL AS "RF"
LOOP
1
5849
ENROLL AS "RF"
LOOP
1
(SOUND)
LOOP
1
(MOTION)
5890
ENROLL AS "RF"
5816
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
5827
SET HOUSE CODE 5827BD
SET HOUSE CODE
5816MN
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
5819
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 3
(TERMINALS)
YOU MUST
ENROLL
THIS
BUTTON
LOOP 3
LOOP 1
LOOP 2
LOOP 4
5804
ENROLL AS "BR"
5804BD
ENROLL AS "BR"
LOOP 3 LOOP 1
LOOP 2
LOOP 4
SET
HOUSE
CODE
•
•
••
•
•••
•
•
•
••
•
•
•
•••
YOU MUST
ENROLL THIS
BUTTON
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
5802MN2
ENROLL AS "UR" OR "RF"
LOOP
1
LOOP
1
5809
ENROLL AS "RF"
5814
ENROLL AS "RF"
LOOP
1
(REED)
Keypad Functions (when default programming is used)
Security Functions
Checking system status: STATUS (high level messages); press STATUS again for secondary messages.
To arm in STAY mode: Press and hold down STAY (or enter your code + STAY ) See note below.
To restart exit delay: STAY (applies only if system is armed in Stay mode)
To arm in AWAY mode: Press and hold down AWAY (or enter your code + AWAY ) See note below.
To arm with NO DELAY: Press and hold down AWAY or STAY + NO DELAY (or enter your code + the keys
shown) See note below.
To disarm the system and silence alarms: User Code + OFF See note below.
To bypass a zone(s): User Code + BYPASS + 2-digit zone number(s)
To turn Chime mode on or off: FUNCTION + CHIME
Message Center
To record a message: FUNCTION + RECORD
To stop recording before end of 20 seconds: OFF
To play back a message: FUNCTION +PLAY
Volume Control
To adjust message playback/system announcement volume: FUNCTION + VOLUME + [3] (Up) or [6] (Down)
To mute system announcements: FUNCTION +VOLUME + OFF
To restore announcement sounding: FUNCTION + VOLUME + [3] or [6]
Other Functions
To set the time and date: User Code +FUNCTION + [63]
To activate or deactivate devices 1-6: FUNCTION + LIGHTS ON or LIGHTS OFF + device number
To activate or deactivate devices 7 & 8: User Code + # + LIGHTS ON or LIGHTS OFF + dev. no.
To add a User Code: Master Code + CODE + user number + User’s Code (see note below)
To delete a User Code (except Master Code): Master Code + CODE + user number
To turn Test mode on: User Code + TEST
To turn Test mode off: User Code + OFF
To use the defined AUX function: Press and hold AUX key 2 secs (4 beeps) + User Code
(To define the AUX function, refer to the procedure in the Aux Function section of the User Manual.
Note: The 1-button paging feature [field *87] is not enabled with the default programming)
NOTE: The Babysitter Code and Installer Code cannot disarm the system unless it was the
code used to arm the system. In addition, if the system is armed by pressing and
holding the Quick-Arm buttons, neither the Babysitter Code nor the Installer Code can
disarm the system.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE LIMITATIONS OF THIS
SYSTEM AND WARRANTY INFORMATION.
175 Eileen Way, Syosset, New York 11791
http://www.firstalertpro.com
Copyright © 1998 PITTWAY CORP.
¬146§l
N8889-1QS 9/98

Other manuals for ReadyGuard

1

Other First Alert Security System manuals

First Alert CO606 User manual

First Alert

First Alert CO606 User manual

First Alert FA168C-GP Operating instructions

First Alert

First Alert FA168C-GP Operating instructions

First Alert FA168C-CN User manual

First Alert

First Alert FA168C-CN User manual

First Alert FA162C User manual

First Alert

First Alert FA162C User manual

First Alert FA1660C Assembly instructions

First Alert

First Alert FA1660C Assembly instructions

First Alert FA142C User manual

First Alert

First Alert FA142C User manual

First Alert DWB-700 User manual

First Alert

First Alert DWB-700 User manual

First Alert FA140C User manual

First Alert

First Alert FA140C User manual

First Alert FA148CP Series User manual

First Alert

First Alert FA148CP Series User manual

First Alert FA148CP Series User manual

First Alert

First Alert FA148CP Series User manual

First Alert ReadyGuard-RI User manual

First Alert

First Alert ReadyGuard-RI User manual

First Alert 1501 User manual

First Alert

First Alert 1501 User manual

First Alert Hearing Impaired Strobe Lights SL177 User manual

First Alert

First Alert Hearing Impaired Strobe Lights SL177 User manual

First Alert HD6135FB User manual

First Alert

First Alert HD6135FB User manual

First Alert 4696780891 User manual

First Alert

First Alert 4696780891 User manual

First Alert DWS-401 User manual

First Alert

First Alert DWS-401 User manual

First Alert D-575 User manual

First Alert

First Alert D-575 User manual

First Alert First Alert CO400 User manual

First Alert

First Alert First Alert CO400 User manual

First Alert 4800 User manual

First Alert

First Alert 4800 User manual

First Alert Onelink Safe & Sound User manual

First Alert

First Alert Onelink Safe & Sound User manual

First Alert CO615 User manual

First Alert

First Alert CO615 User manual

First Alert 3035DF How to use

First Alert

First Alert 3035DF How to use

First Alert F250 User manual

First Alert

First Alert F250 User manual

First Alert SFA600 User manual

First Alert

First Alert SFA600 User manual

Popular Security System manuals by other brands

Siemens FDM273-O Mounting

Siemens

Siemens FDM273-O Mounting

Swann SWIFI-ISIREN quick start guide

Swann

Swann SWIFI-ISIREN quick start guide

Commax CDS-2AG user manual

Commax

Commax CDS-2AG user manual

KALEAS KlimaDetector operating instructions

KALEAS

KALEAS KlimaDetector operating instructions

Silent Beacon SB101 user guide

Silent Beacon

Silent Beacon SB101 user guide

Adtech ACA 140 instruction manual

Adtech

Adtech ACA 140 instruction manual

Panasonic KX-HNS105AZ installation guide

Panasonic

Panasonic KX-HNS105AZ installation guide

Videofied W730 manual

Videofied

Videofied W730 manual

Pyle plcmtr82wir user manual

Pyle

Pyle plcmtr82wir user manual

PCE Health and Fitness PCE-WSAC 50W Series user manual

PCE Health and Fitness

PCE Health and Fitness PCE-WSAC 50W Series user manual

Niko 05-203-01 user manual

Niko

Niko 05-203-01 user manual

Fermax LOFT VDS 1L User& installer's manual

Fermax

Fermax LOFT VDS 1L User& installer's manual

Lorex SG17F6584 instruction manual

Lorex

Lorex SG17F6584 instruction manual

IR LAB LIR-IG89 user manual

IR LAB

IR LAB LIR-IG89 user manual

Britax BFR1000 Series Installation & operation manual

Britax

Britax BFR1000 Series Installation & operation manual

Honeywell Ademco VISTA-20P Quick installation guide

Honeywell

Honeywell Ademco VISTA-20P Quick installation guide

IDESA ideTronic HPS 841 Using instructions

IDESA

IDESA ideTronic HPS 841 Using instructions

saphe Saphe Drive manual

saphe

saphe Saphe Drive manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.