Quick Start Guide
Fit the appropriate mains
adaptor to the charger (see
“Baery Charging” page 6).
Connect the baery charger
to a mains power socket and
the Airo 12 charging
socket.
CHARGE THE BATTERY FOR 16 HOURS BEFORE
USE.
To calibrate the baery and baery indicator,
it is essenal before the rst use to charge for
16 hours and then disconnect from the charger
and leave for 90 minutes to allow the baery
management soware to correctly calibrate.
WARNING: THE AIRFLO MUST BE PUT ON CHARGE FOR 16 HOURS BEFORE FIRST USE.
To calibrate the baery and baery indicator, it is essenal before the rst
use to charge for 16 hours and then disconnect from the charger and leave
for 90 minutes to allow the baery management soware to correctly
calibrate. Failure to do this could lead to incorrect baery charging and
baery ladder indicaon.
1
2
First 6
Hours
16 Hours
Fully
Charged
For the rst 6 hours, the boom light will
ash green. Aer 6 hours the rst light will
become a steady green and the second light
will start ashing. Charging cycle connues
unl lights are lit. Then aer 16 hours the
charge is complete with the top light ashing
and other 3 will be o.
Once a red LED and Deate Lock has been acvated during discharge (see page 3), a 2
hour plus charge is required to reset the Deate Lock.
GREEN GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN

Healthcare solutions designed for life
3
Quick Start Guide
Press the hand control or
Airo 12 built-in buons
to raise or lower the liing
equipment.
3
Connect the hose from
the Mangar pneumac
liing equipment.
2
Connect the Hand Control.
1
WARNING: The baery must be put on charge immediately as soon as the red indicator light appears. Running
the Airo 12 on RED unl the baery is exhausted will damage the baery.
TO DETERMINE THE BATTERY CHARGE STATE, YOU MUST DISCONNECT THE CHARGING LEAD AND
THEN PRESS THE ‘BATTERY STATUS INDICATOR’ BUTTON TO ACTIVATE THE BATTERY STATUS INDICATOR
LIGHTS:
Baery Status
Indicator
Buon
RED
DO NOT USE
RECHARGE
2 GREEN
Recharge
Soon
3 GREEN
OK to Use
4 GREEN
OK to Use
1 GREEN
Recharge Before
Next Use
IMPORTANT: The Airo 12 is designed not to deate if there is insucient baery voltage to fully inate the
liing product. This safety feature stops an inatable bathing product from being lowered to the boom of
a bath if there is insucient baery voltage to raise it again.
Operang
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN RED

4
Airo 12
The Airo 12 by Mangar Health is a low
pressure air compressor, which has been
designed to inate a range of Mangar Health
pneumac liing equipment.
Applied Parts (Accessories) for the Airo 12:
Bathing Cushion
Handy Pillow Li
Sit-u-Up Pillow Li
Leglier
Surfer Bather
Raiser
•Be sure that you have read and understood these
instrucons and those provided with any other
Mangar Health product, before operang the
equipment.
•To avoid the risk of electric shock, NEVER
recharge the baery in the bathroom, outdoors
or in a damp environment.
•Always disconnect from the baery charger
before cleaning.
•Use only the supplied baery charger.
•Do not operate the Airo 12 compressor in the
presence of ammable anaesthec mixtures with
air, oxygen or nitrous oxide, as these mixtures
can create a combusble environment leading to
the potenal for re or even an explosion in the
presence of a spark.
•Ensure that when in use, the Airo 12 and its
connected hose and hand control lead are laid
out in such a way as to avoid any risk of tripping
or strangulaon.
•Ensure that children and pets do not interfere
with the safe operaon of the Airo 12 and
inatable product.
•Keep the Airo 12 and inatable product away
from sources of heat.
•Disconnect the Airo 12 compressor from the
inatable product before transporng so as to
avoid accidental inaon.
•The Airo 12 should only be used for its stated
purpose and should not be modied in any way.
•The oponal mains power adaptor is specic to
the Airo 12 and is the only approved unit to be
used for this purpose.
•Do not operate the compressor outside of the
specied duty cycle of 20% ‘Operang Time’ and
80% ‘Non-Operang Time’. Maximum connuous
operang me = 5 minutes.
Intended Use Pg 4
Warnings Pg 4
Standard Package Contents Pg 5
Baery Status Indicator Pg 5
Baery Charging Pg 6
Mains Power Adaptor (oponal) Pg 7
Operaon Pg 7
Cleaning & Storage Pg 8
Maintenance Pg 8
Trouble shoong guide Pg 9
Specicaons Pg 9
Symbols used on Airo 12 and Charger Pg 10
Symbols used on packaging Pg 11
Warranty Pg 11
Declaraon of Conformity Pg 42
The Mangar Airo 12 compressor along with
the correct selecon of inatable device as
listed above can be used by:
•A person with sucient upper body
strength who requires assistance in moving
or support, to do so on their own.
•A person who is assisng the user to move
or be supported.
•No special skills or training are required to
operate the Airo 12 and its accessories.
Further guidance on operaon can be found in
the individual accessory User Instrucons.
The Airo compressor and applied parts are
intended for connual re-use as required and
no special acons or operaons are needed to
achieve this.
Intended Use
WARNINGS
Contents
This product and associated packaging does not
contain latex.

Healthcare solutions designed for life
5
Airo 12
Standard Package Contents - g. 1
1 x Airo 12 compressor (A) ed with a
12v - 2200mAh Ni-MH baery pack.
1 x Baery charger (with adaptors) (B).
1 x 2-Way hand control (C).
1 x User Instrucons.
1 x Mains Power Adaptor (Oponal).
Baery Status Indicator
Geng Started
The Airo 12 does not have an ‘on/o’ switch.
To operate the compressor, press the ‘Up’
buon on the Airo or on the hand control.
Up Down
WARNING: The baery must be put on charge immediately as soon as the red indicator light appears.
Running the Airo 12 on RED unl the baery is exhausted will damage the baery.
When the compressor is running, the baery status indicator lights will only indicate the state of baery
charge as it was at the start of the li. When the compressor stops running, the baery status indicator
lights will go o. To determine the true baery state following a li, press the ‘Baery Status Indicator’
buon and the lights will indicate the baery charge state.
IMPORTANT: To maximize the life and liing performance of the baery, fully recharge the baery for 16
hours.
Fully charge the baery for a minimum of 16 hours before using the Airo 12 for the rst me; and
when a new baery has been ed. Then disconnect from the charger and leave for 90 minutes to
allow the baery management soware to correctly calibrate. Failure to do this could lead to incorrect
baery charging and baery ladder indicaon.
To determine the baery charge state before use, press the ‘Baery Status Indicator’ buon to acvate
the baery status indicator lights:
NOTE: DO NOT PRESS THE ‘BATTERY STATUS INDICATOR’ BUTTON WHILST THE BATTERY
CHARGER LEAD IS CONNECTED.
1
A
B
C
Baery Status
Indicator
Buon
RED
DO NOT USE
RECHARGE
2 GREEN
Recharge
Soon
3 GREEN
OK to Use
4 GREEN
OK to Use
1 GREEN
Recharge Before
Next Use
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN RED

6
Airo 12
2
First 6
Hours
16
Hours
Baery Charging - gs. 2
•Check the baery charger casing and lead
for signs of damage and if damaged DO
NOT USE.
• Fit the appropriate mains plug adaptor to
the baery charger (A).
•Plug the baery charger into a mains
power socket and connect the charger
output lead to the Airo 12 charging
socket (B).
NOTE: When rst ng a baery they must
be charged for a minimum of 16 hours to
achieve full capacity. On subsequent charges
the Airo calculates the charging period
based on usage and will not necessarily start
at the boom light ashing.
When the baery is being charged:
•For the rst 6 hours, the boom light
will ash green. Aer 6 hours the rst
light will become a steady green and the
second light will start ashing. Charging
cycle connues unl all lights are lit.
•Aer 16 hours the charge will be
complete and the compressor will move
into an energy saving mode with the top
LED ashing every 6 seconds and the
other 3 will be o.
B
A
NOTE: If charging is momentarily interrupted (a power cut, switching the power socket o or
disconnecng the charging lead), on re-connecon, the charging process will resume at the
same charge sequence point.
To maintain baery condion, it is recommended that the Airo 12 is le connuously on charge
when not in use. The baeries cannot be overcharged using this charger.
WARNING: DO NOT recharge the baeries in a bathroom or in a damp environment.
GREEN GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN

Healthcare solutions designed for life
7
Airo 12
Operaon - g. 4
When used with Bathing accessory disconnect the Airo
12 from the baery charger and place it in a safe and
convenient posion.
•Connect the Hand Control plug (A) to the Airo 12 hand
control socket (B).
•Connect the hose from the Mangar pneumac liing
equipment to the Airo 12 air outlet socket (C). The
connector will ‘click’ into place when rmly pushed
onto the socket.
•Press the ‘Up’ buon (D) to raise.
•Press the ‘Down’ buon (E) to lower.
•Alternavely press the Airo 12 built in buons to raise
or lower the equipment.
NOTE: When either the ‘Up’ or ‘Down’ buons are pressed,
a baery voltage check is carried out and if the voltage
becomes too low, the ‘Down’ buon will not work. This
feature will always ensure that the seat of a Mangar Health
bathing product cannot be lowered into a bath if there is
insucient baery power to raise it again.
D
E
4
C
B
A
3
Mains Power Adaptor (oponal)
An oponal mains power adaptor is available to power the
Airo 12 directly from a mains power socket. The adaptor
is specic to the Airo 12 and is the only approved unit to
be used for this purpose. Connect the adaptor between a
mains power socket and the adaptor inlet socket on the end
of the Airo 12 (Fig. 3).
NOTE: This adaptor, has a non-standard output connector
and powers the Airo 12 directly, it will not charge the
baery. The only way to charge the baery is to use the
charger which was supplied with the Airo 12. With the
power adaptor connected, the Airo 12 behaves in the
same way as if it was running on the baery, the only
funconal dierence is that the baery indicator light will
show boom LED orange. With the adaptor connected, the
Airo 12 will also run if there is no baery ed.
WARNING: DO NOT use the mains power adaptor in a
bathroom or in a damp environment.

8
Airo 12
Maintenance - g. 5
The Airo 12 has been designed to be maintenance
free and apart from replacing the baery, the Airo 12
contains no other user serviceable parts
Baery replacement:
•Turn the Airo 12 onto its end containing the air
outlet socket, remove the screw (A) and slide the
end panel (B) away from the housing.
•Disconnect the wire from the baery pack
and remove the baery pack from the baery
compartment leaving the foam block in place.
•Fit the replacement baery pack, ensuring that the
connector is secure, ret the end panel and secure
the screw (A).
A
B
5
Disposal
When the Airo 12 has reached the end of it’s working life, remove the baery for safe disposal
in accordance with local regulaons, and dispose of the Airo 12 at your local household waste
recycling centre (civic amenity site).
Cleaning
•Unless contaminaon is suspected, periodic cleaning is all that is recommended. The Airo 12
should be cleaned/disinfected as follows:
•Unplug the Airo 12 from the baery charger. Clean the external surfaces using a non abrasive
damp cloth with warm water. Wipe dry thoroughly with a dry towel before reconnecng to the
baery charger. Do not allow moisture to enter any part of the compressor.
•Do not use solvent-based products.
Disinfecng
•Pre-clean using a damp cloth and then disinfect using a hard surface alcohol impregnated
wipe.
Storage
•When not in use, store in a dry place together with these instrucons. To maintain the baeries,
when being stored for long periods, put the Airo 12 on charge for 16 hours every 3 months.
NOTE: Ensure that the baeries are fully charged before storing the Airo 12 for long periods.
When it becomes apparent that the Airo 12 is producing fewer than expected liing cycles, the
baery is probably reaching the end of its working life and should be replaced.
If a fault should develop or if you require assistance in seng up using or maintaining the
equipment, please contact our Customer Service Department on Freephone 0800 2800 485 (UK
only. Outside of the UK please contact your supplier).

Healthcare solutions designed for life
9
Airo 12
Airo 12
Weight: 3.7Kg (8 lbs)
Output pressure: 0.25 bar (3.75 psi)
Baeries: 1 x 12v - 2200mAh Ni-MH baery pack (CD0315)
Baery Life: Greater than 500 charging cycles (2 - 5 years depending on usage)
Environmental protecon:
(Airo 12 housing) IP41 (Protecon from entry by solid objects with a diameter or
thickness greater than 1.0mm & dripping water)
(Push-buon hand control) IP67 (Protected against immersion upto 30 minutes)
Type BF equipment
This equipment has been tested and meets the requirements of current EMC legislaon
Charger: Model number - HX1506SR
Input: AC 100v - 240v, 50-60Hz, 0.5A Max
Output: DC 15v, 0.35A
Class II Double insulated equipment.
Specicaons
Trouble shoong guide
Problem Remedy
•Compressor does not run when ‘up’ is
selected.
•Ensure that the air hose from the product
being inated is connected to the Airo.
•Check that there are no kinks in the air hose.
•Compressor keeps stopping when trying to
inate the liing aid. •Check that there are no kinks in the air hose.
•Boom Baery Status Indicator light solid
‘Red’ and product will not deate.
•Low baery capacity, recharge for a
minimum of 2 hours.
•Boom Baery Status Indicator ashing red
every 2 seconds.
•Internal pump temperature too high - allow a
cool down period of 60-90 minutes.
•Boom Baery status indicator ashing Red
every ½ second.
•Current overload. Check there are no kinks in
in the air hose.
•Compressor causes electrical interference
with another piece of electrical equipment.
•Move either the compressor or other item
further away from each other unl the
interference stops.

10
Airo 12
Symbols used on Airo 12 and Charger labels
For indoor use only. Do Not
connect to mains power in a
bathroom or outdoors.
‘Up’ buon
‘Down’ buon
Alternang current (AC)
Fuse (with rang)
Direct current (DC)
Type BF equipment (protecon
against electric shock)
Max/Min operang environment
temperature
Aenon consult instrucons
Warning
Class II Double Insulated
equipment
Dangerous voltage
Duty cycle
I = Operang me
O = Non operang me
(Max connuous operang me = 5
minutes)
Recycle
Do not dispose of in household
waste
Date of manufacture
Baery Status Indicator Buon

Healthcare solutions designed for life
11
Airo 12
Symbols used on packaging
Keep packaging dry
Handle with care
Max/Min storage temperature
Net & gross weights
Stack no more than ve high
Recycle packaging
Do not dispose of in household
waste
Airo 12 serial number: .............................
Date of purchase: .............................
Invoice/Delivery note number: .........................
Warranty
The warranty is given against defects in material and workmanship and comprises piece, parts and
labour. The warranty is not valid in the case of fair wear and tear, wilful damage, common neglect,
misuse or unauthorised alteraon or repair by unqualied persons.
The following statements do not aect the consumer’s statutory rights. This product is sold on the
understanding that in the event of any defect of manufacture or material appearing within the
warranty period, the defect will be reced free of charge providing that:
(a) Reasonable evidence is provided (e.g. purchase invoice, delivery note) that the claim is being
made within the warranty period.
(b) The defect is not aributable to accidental damage (either in transit or otherwise), misuse
or unauthorised repair.
Max/Min humidity when transporng
or in storage
Max/Min pressure when transporng
or in storage
Max/Min temperature when
transporng or in storage
Mangar Internaonal Ltd, trading as Mangar Health, reserves the right to alter product specicaons and/or any of the informaon contained within
this document without noce.

12
Airo 12

Healthcare solutions designed for life
13
Airo 12

Healthcare solutions designed for life
MI0353 issue 6
(08/20)
Mangar Internaonal Ltd
Presteigne, Powys, Wales, LD8 2UF
United Kingdom
Tel: +44 (0)1544 267674
Fax: +44 (0)1544 260287
E-mail: sales@mangarhealth.com
www.mangarhealth.com
Other manuals for Airflo 12
2
Table of contents
Other Mangar Air Compressor manuals
Popular Air Compressor manuals by other brands

EINHELL
EINHELL BT-AB 19/4 Kit operating instructions

GMC
GMC 40L instruction manual

Airpress
Airpress HLO 215/25 user manual

Quincy Compressor
Quincy Compressor HP 15 Manual use and maintenance

Craftsman
Craftsman AIR COMPRESSOR 919.724701 owner's manual

California Air Tools
California Air Tools 263DlH owner's manual