manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Marco
  6. •
  7. Chiller
  8. •
  9. Marco 1000860US User manual

Marco 1000860US User manual

For more information visit www.marcobeveragesystems.com
FRIIA C HANDS-FREE FONT DIMS
12”
13.5”
5.4”
CHILLERFONTS
> Sleek and stylish touchless
cold-water font
> Safe and hygienic:
eliminates touchpoint
NAME
ORDER CODE
DIMENSIONS INC. DRIP TRAY
(D X W X H inches)
DIMENSIONS EXCL. DRIP TRAY
(D X W X H inches)
TAP TO COUNTER
(inches)
FRIIA C Hands-free Font
1000857 6.6 x 4.7 x 13.5 5.4 x 1.1 x 13.5 12
ORDER CODE (Complete bundle)
> FRIIA C Hands-free 5000857US
PACKAGING
ITEM PACKAGING DIMENSIONS
(L x W x H inches) WEIGHT
Fonts (all) 11.4 x 22.4 x 8.4 4.4lbs
Chiller 19.2 x 11.8 x 20.2 69.4lbs
FRIIA components (font
and chiller) are packed and
shipped in individual boxes.
PLEASE
NOTE
CHILLER SYSTEM SET-UP
PRODUCT INFO SIZE PERFORMANCE SPECS PLUMBING, ELECTRICAL AND TECHNICAL SPECS
NAME
ORDER CODE
DIMENSIONS
(D X W X H inches)GAL/HR CUPS
/HR
POWER
@110V
PLUMBING
REQS
COMPRESSOR
POWER CHARGE REFRIGERANT
Chiller
1000860US 17.1 x 10.2 x 17.9
7.9-11.8 GALS/hr based
on incoming water temp
of 59°F and output water
temp of 41-44°F
175-235
(ΔT =
18 °F)
180W
3/8”
Compression
or 3/8” John
Guest
1/8hp 45g R290
FRIIA HANDS-FREE COLD
A minimum operating pressure of 2 bar or 28 psi downstream of filter is required for optimum output l/min.
For more information visit www.marcobeveragesystems.com
FRIIA C & FRIIA CS & FRIIA C HANDS-FREE
FRIIA C/ FRIIA CS /FRIIA C HANDS-FREE
COUNTER CUT-OUT WITH DRIP TRAY
FRIIA C 5000860US
FRIIA C Tall 5000863US
FRIIA C Hands-Free 5000857
FRIIA CS 5000862US
FRIIA CS Tall 5000865US
VENTILATION REQUIREMENTS
FRONT VENTILATION: Ventilation grilles cut out of standard cabinet door.
SIDE VENTILATION: Ventilation grilles cut out of standard 600mm
cabinet. Grilles may be fitted on either side as long as they ventilate
into an open unobstructed area.
BASE VENTILATION: Ventilation grilles cut in base panel and base
plinth, a grille must also be cut out at the top of the cabinet.
• At least 2 x vents 260mm/10.2” w x 65mm/2.5 h
• The cabinet may be ventilated in many ways provided there are cut
outs placed near the base and another near the top of the cabinet
to take advantage of natural circulation.
UNPACKING INSTRUCTIONS
• The chiller must be handled only in a vertical position. Transporting
the appliance in a horizontal position can cause severe damage to
the refrigerator.
• Remove the exterior and interior packing. Packing materials
(especially any plastic bags) should be stored out of the reach
of children, as a potential source of danger. When disposing
packaging parts, please follow current regulations on the matter,
separating carton from plastic parts.
• Always check that the equipment that is delivered corresponds to
the model indicated in the accompanying document.
• The equipment is shipped in a cardboard box. Once the packaging
has been removed, check the equipment has not been damaged in
transit; if damage is found, notify the carrier.
ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local regulations and
standards. The appliance is supplied with a moulded power cord. A
suitable mains power supply socket should be available within easy
access of the appliance so that it can be disconnected easily after install.
The standard machines are supplied with a UK 3-pin plug. For
EU models a 2-pin CEE-7 plug will be supplied. US models will be
supplied with the suitable plug. A suitable mains power supply socket
should be available within easy access of the appliance so that it
can be disconnected easily after install. The wires from the font are
terminated in a Mini Fit connector which will plug into a similar Mini Fit
connector mounted on the top lid of the undercounter boiler.
PLUMBING INSTALLATION PROCEDURE
• Ensure that the equipment is installed according to local plumbing
& water regulations.
• Fit a stop valve on a cold water line and attach a 3/4” BSP male
fitting, (eg. 3/4” x 1/2” 311 or washing machine type stop valve).
Suitable fittings are supplied with the kit to attach to 3/8”
Compression or 3/8” John Guest.
• Connect water supply lines following the installation drawings,
as per installation guide.
• In case filter systems are used verify that they satisfy the
requirements of the legislation in force.
• If the filter is new, turn on water and flush at least 10 liters
(2.5 gallon) through the filter before to connect it to the cooler;
if the filter is a used one, connect water inlet to the chiller.
• To ensure that the maximum value of pressure of 3 Bar is not
exceeded the chiller integrates a pressure reducer.
• Turn on the water to flush any impurities, dust etc from the inlet hose and
water pipe. Allow several litres through. Especially for new installations.
OPERATING THE CHILLER/CARBONATOR FOR THE
FIRST TIME
• Before connecting the appliance to the power source, let it stand upright
for approximately 2 hours. This will reduce the possibility of a malfunction.
• Check that all installation procedures have been carried out.
• Ensure water inlet is open.
• Before supplying power to the unit check water and Carbon Dioxide
lines do not leak.
• Plug the chiller into a suitable socket switch ON/OFF switch on the rear
of the chiller to ON position. The “Power ON Status” light will light-up.
• When the unit is on, the carbonation pump starts to fill. The
carbonation device stops when it reaches the maximum level.
• Once water and CO2 are connected, open the vent on top of the
Chiller by pulling the ring. This operation allows the escape of any air
bubbles present inside, which would affect the carbonation adversely.
• On the pressure reducer knob, adjust CO2 pressure to a value
between 50 and 65 PSI (350 and 450 kPa) (3.5 - 4.5 bar). This value
depends on the temperature of the water and on the ambient
temperature. The temperatures correspond to the CO2 pressure.
• To enable filling the lines, open the two lines in the following order:
cold sparkling water and cold natural water, until the flows appear
regular and without the presence of air, in each case deliver and
discharge at least 5 litres of water from each line.
• At this point you can dispense water.
Cold / Sparkling
Power
1401482
1400820
Cold/Sparkling
Water
2301251
369
437
600
600
100 min.
275
200
Applies to model(s) 1000850# & 1000851# (where # is blank, or one or more alphanumeric characters)
DRAWN BY
DWG NO.:
PANEL REMOVAL
DESCRIPTION:
PJT
20-08-14
187
C.O.
FRIIA Assembly (in cabinet)
31.5”/800mm
11.2”/
287mm
17.9”/
455mm
10.2”/259mm
13.5”/
345mm
4”/100mm
For drip-tray only
1.25”/32mm
3.25”/82.5mm
6.6”/168mm
For more information visit www.marcobeveragesystems.com
RADIUS OF MAXIMUM FONT PLACEMENT
COUNTER CUT-OUTS
VENTILATION
OR OR
It is essential to allow for two ventilation points when installing FRIIA. Vents are not supplied. Where possible,
we recommend removing the back of your cabinet.
PLEASE
NOTE
CABINET
Min: 31.5” (h) x 23.6” (w) x 23.6” (d) with 3.9” clearance around
machines all sides
OPERATING ENVIRONMENT
Cannot exceed temperature of 95°F
3.1”/80mm
11.8”/300mm
10.2”/260mm
2.5”
/65mm
1.9”/50mm
2.5”/65mm
10.4”/265mm
10.4”/265mm 1.9”/50mm
2.5”/65mm
4”/100mm
For drip-tray only
1.25”/32mm
3.25”/82.5mm
6.6”/168mm
Standard
31.5” high
cabinet
23.6”/600mm
FRIIA SYSTEM OVERVIEW
For more information visit www.marcobeveragesystems.com
FRIIA PERFORMANCE AND MAINTENANCE
> Wipe down font daily with non-abrasive cleaner.
> Sanitize the chiller every 6 months, after a filter change or after a period of inactivity (more than 72 hours).
Visit our YouTube channel for further instruction.
HOW TO
CLEAN FRIIA
> FRIIA requires use of both a HOT (scale reducing filter if limescale is present) and COLD (carbon
block for taste and odour) water filters for FRIIA. Please contact us for advice on the best water filter.
> Descale the MIX boiler if scale is present in the water.
MAINTENANCE
13.2
11.8
10.5
9.2
7.9
6.6
5.2
3.9
2.6
1.3
0
Output Temp 37.4°F Output Temp 41°F Output Temp 44.6°F
5950 68 77 82.4 86 95 104
FRIIA OUTPUT VOLUME
Based on flow rate of 0.3 GAL/min and ambient temperature of 68-77°F. Chart indicates FRIIA
chilling capacity based on incoming water temperature and desired output water temperate.
INCOMING TEMPERATURE (°F)
OUTPUT VOLUME (GAL/H)

Other Marco Chiller manuals

Marco FRIIA COLD User manual

Marco

Marco FRIIA COLD User manual

Marco FRIIA Series User manual

Marco

Marco FRIIA Series User manual

Marco FRIIA HC User manual

Marco

Marco FRIIA HC User manual

Marco FRIIA Lite User manual

Marco

Marco FRIIA Lite User manual

Marco FRIIA Lite User manual

Marco

Marco FRIIA Lite User manual

Popular Chiller manuals by other brands

York MILLENNIUM YCAS Installation operation & maintenance

York

York MILLENNIUM YCAS Installation operation & maintenance

Castel MAC T3 user guide

Castel MAC

Castel MAC T3 user guide

hailea HC-1000A instruction manual

hailea

hailea HC-1000A instruction manual

York MILLENNIUM YK Operating & Maintenance

York

York MILLENNIUM YK Operating & Maintenance

Zip 802261 installation instructions

Zip

Zip 802261 installation instructions

Sterling A0554831 user manual

Sterling

Sterling A0554831 user manual

Sinclair SCV-50EA Service manual

Sinclair

Sinclair SCV-50EA Service manual

CLIVET WSAT-YSC4 manual

CLIVET

CLIVET WSAT-YSC4 manual

Hyco Sapphire SAPUC1 Product instruction manual

Hyco

Hyco Sapphire SAPUC1 Product instruction manual

Nordcap SKF 7 GN 1/1 Installation

Nordcap

Nordcap SKF 7 GN 1/1 Installation

Daikin WGZ030DW Installation, operation and maintenance manual

Daikin

Daikin WGZ030DW Installation, operation and maintenance manual

Lennox MWC 180 Application guide

Lennox

Lennox MWC 180 Application guide

York Millennium YCAJ150 Installation operation & maintenance

York

York Millennium YCAJ150 Installation operation & maintenance

Skope BB Series user manual

Skope

Skope BB Series user manual

Trane CGAD020C manual

Trane

Trane CGAD020C manual

Hoshizaki Lancer P400T V2 Installation, operation & service manual

Hoshizaki

Hoshizaki Lancer P400T V2 Installation, operation & service manual

Advanced Thermoelectric ElectraCOOL L-A 550 user manual

Advanced Thermoelectric

Advanced Thermoelectric ElectraCOOL L-A 550 user manual

Carrier 40UV Installation, Start-Up and Service Instructions

Carrier

Carrier 40UV Installation, Start-Up and Service Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.