ÜBER FONTS WITH UNDERCOUNTER BOILERS
ECO RANGE
DIMENSIONS SYSTEM SET-UP
COUNTER CUT-OUTS
BOILERS FONTS
PRODUCT
INFO WATER TYPE SIZE PERFORMANCE SPECS PLUMBING &
ELECTRICAL REQS PACKAGING
NAME
ORDER CODE
MULTI-
TEMP
ADJUST
TEMP
DIMENSIONS
(D x W x H
inches)
IMMEDIATE
DRAW OFF
GAL/
HOUR
CUPS
(180ml)
/HOUR
POWER
@ 220V NEMA PLUMBING
REQS
PACKED
WEIGHT
PACKAGING
DIMENSIONS
(L x W x H
inches)
QTY /
PALLET
Ecosmart UC4
1000750US
N
Y
15.5 x 5.2
x 23 1 GAL
7.3 156
2.4kW L6-20P
3/8”
Compression
or 3/8” John
Guest
24lbs
19.7 x 9.4
x 27
20
Ecosmart UC10
1000752US
15.5 x 8.8
x 23 2.6 GAL
5.6kW
@ 230V L6-30P
33lbs 10
Ecosmart UC45
1000754US
19.4 x 16.5 x
26.2 11.8 GAL 14.7 311 49lbs 19.7 x 16.5
x 27 4
Ecoboiler UC4
110v
1000740
N15.5 x 5.3
x 23 1 GAL 3.6 75 1.4kW
@110v 5-15p 24lbs 19.7 x 9.4
x 27 20
PRODUCT INFO FONT DIMENSIONS PACKAGING
NAME ORDER
CODE
DIMENSIONS
(D x W x H inches)
TAP TO COUNTER
(T inches)
PACKED
WEIGHT
PACKAGING DIMENSIONS
(L x W x H inches)
QTY /
PALLET
Über Font 1000811 18.5 x 9.8 x 15.7 11.5
17.6lb 19.2 x 11 x 26.3 18
Über Font (Low) 1000811L 18.5 x 9.8 x 10.7 6.8
H
D
W
T
H
D
W
T
23”/585mm
>27.6”/700mm
15.5”/395mm
2”/50mm
15.7”/400mm
11.6”/
295mm
18.5”/470mm
Front of Font
14.6”/370mm
6.5”/165mm
Water
Power
Vent
Boiler Connections to Font
min 5.1”
/130mm*
ÜBER FONT
FONT VARIANTS
2 Connections
Low Profile 2 connections
• Available in two heights
• Can be used with 1 or 2 undercounter boilers
For more information visit www.marcobeveragesystems.com
ÜBER FONT WITH ECOBOILER UC4 & ECOSMART UC4, UC10 & UC45
COUNTER
CUT-OUT
ÜBER FONT
1000812/1000811
ECOBOILER UC4 1000747US
ECOSMART UC4 1000750US
ECOSMART UC10
1000752US
ECOSMART UC45
1000754US
23”/585mm
15.5”/395mm
2”/50mm
11.9”/303mm
* Hosing should
be trimmed to
ensure continuous
drop from font
to boiler
4.5”/114mm
Ø 1.3”/32mm
Boiler Connections to Font
Water
Power Vent
2”/50mm*
2”/50mm
* Required for ventilation
if the machine is installed
in an enclosed cabinet.
>27.6”/700mm
min 5.1”/
130mm*
6.1”/
156mm
23”/585mm
>27.6”/700mm
15.5”/395mm
2”/50mm
15.7”/400mm
11.6”/
295mm
18.5”/470mm
Front of Font
14.6”/370mm
6.5”/165mm
Water
Power
Vent
Boiler Connections to Font
min 5.1”
/130mm*
VENTILATION REQUIREMENTS
50mm/1.9” clearance required at each side and back of
machine if installed in an enclosed cabinet.
ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local
regulations and standards. The appliance is either supplied
with a NEMA L6-20P moulded power cord or a 515P power
cord. A suitable mains power supply socket should be
available within easy access of the appliance so that it can
be disconnected easily after install. The wires from the font
are terminated in a Mini Fit connector which will plug into
a similar Mini Fit connector mounted on the top lid of the
undercounter boiler.
PLUMBING INSTALLATION PROCEDURE
• Ensure that the equipment is installed according to
local plumbing & water regulations.
• Mains water pressure required (limits): 14.5 -145psi
(100 -1000kPa, 0.1 - 1MPa).
• Requires inline water filter within your water
specifications.
• The machine requires either a 3/8” compression,
or 3/8” John Guest water connection.
• Turn on the water to flush any impurities, dust etc
from the inlet hose and water pipe. Allow several litres
through. Especially for new installations. Connect the
hose to the inlet valve of the boiler. Make sure a sealing
washer is fitted.
• Turn on water and check for leaks.
• If the overflow vent is plumbed it must be plumbed with
a tundish device.
• This equipment must be installed with adequate
backflow protection to comply with all applicable
federal, state and local codes.
OPERATING BOILER FOR THE FIRST TIME
• Check that all installation procedures have been
carried out.
• Ensure water valve is on.
• Plug boiler appropriate electrical supply and press
power button on the front of the machine marked
‘Power’.
• The “power on” light will glow green and the machine will
fill to a safe level, above the elements, before heating.
• The “Ready/Status” light will cycle two red flashes while
the machine is filling to the safe level.
• After this amount of water has heated to about 95ºC
the boiler will draw more water in until the temperature
drops by 1 or 2 degrees. The boiler will then heat again.
This heat fill cycle continues until the boiler is full.
• Whilst the machine is above the safe level and filling,
the “Ready/Status” light will remain blank.
• The “Ready/Status” light will glow green when the
machine is both full and up to normal operating
temperature.
• The boiler is now ready for use.
• The font is simply activated by pressing the button
on the top of the font.
NOTE: Because the boiler is electronically controlled no
priming is necessary. The element cannot switch on until
a safe level of water is reached.
23”/585mm
>27.6”/700mm
15.5”/395mm
2”/50mm
15.7”/400mm
11.6”/
295mm
18.5”/470mm
Front of Font
14.6”/370mm
6.5”/165mm
Water
Power
Vent
Boiler Connections to Font
min 5.1”
/130mm*
* Hosing should
be trimmed
to ensure
continuous drop
from font
to boiler
2”/50mm*
2”/50mm
* Required for ventilation
if the machine is installed
in an enclosed cabinet.
23”/585mm
>27.6”/700mm
15.5”/395mm
2”/50mm
15.7”/400mm
11.6”/
295mm
18.5”/470mm
Front of Font
14.6”/370mm
6.5”/165mm
Boiler Connections to Font
Water
Power Vent
min 5.1”
/130mm*
* Hosing should
be trimmed to
ensure continuous
drop from font
to boiler
2”/50mm*
2”/50mm
* Required for ventilation if the machine
is installed in an enclosed cabinet.
Front of Font
14.6”/370mm
6.5”/165mm
Boiler Connections to Font
Dispense 1
Font #1 Connection
Vent
Dispense 2
Font #2 Connection
19.4”/495mm
2”/50mm
26.2”/667mm
min 5.1”/130mm
15.7”/400mm
11.6”
/295mm
18.5”/470mm
* Hosing should
be trimmed
to ensure
continuous
drop from font
to boiler
ÜBER FONT WITH ECOSMART/ECOBOILER
UNDERCOUNTER WATER BOILERS

This manual suits for next models

2

Other Marco Dispenser manuals

Marco MAXIBREW 2 User manual

Marco

Marco MAXIBREW 2 User manual

Marco JET 6 User manual

Marco

Marco JET 6 User manual

Marco MIX Font User manual

Marco

Marco MIX Font User manual

Marco POUR'D User manual

Marco

Marco POUR'D User manual

Popular Dispenser manuals by other brands

Cornelius Jetspray JT20 owner's manual

Cornelius

Cornelius Jetspray JT20 owner's manual

Guardian SD495 user manual

Guardian

Guardian SD495 user manual

Manitowoc Q Series Installation, Use, Care, and Service Manual

Manitowoc

Manitowoc Q Series Installation, Use, Care, and Service Manual

Signature Hardware 948519 manual

Signature Hardware

Signature Hardware 948519 manual

ESINO Z88 user manual

ESINO

ESINO Z88 user manual

diversey D250 Installation & operating guide

diversey

diversey D250 Installation & operating guide

Sanela SLZN 74 instruction manual

Sanela

Sanela SLZN 74 instruction manual

TPS hydroCHEM manual

TPS

TPS hydroCHEM manual

Biohit eLINE Dispenser Pro user manual

Biohit

Biohit eLINE Dispenser Pro user manual

SIKA PowerCure 400 Original instructions

SIKA

SIKA PowerCure 400 Original instructions

Saunum AutoLEIL Instructions for use

Saunum

Saunum AutoLEIL Instructions for use

Beper P201UTP004 use instructions

Beper

Beper P201UTP004 use instructions

Speidel 41010 operating instructions

Speidel

Speidel 41010 operating instructions

jbc ND-KS instruction manual

jbc

jbc ND-KS instruction manual

Remedic REM280003 quick start guide

Remedic

Remedic REM280003 quick start guide

DRIFTON 2000-D Operation manual

DRIFTON

DRIFTON 2000-D Operation manual

START International TDA025 instruction manual

START International

START International TDA025 instruction manual

Newco NHW-15 operating manual

Newco

Newco NHW-15 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.