manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Mark
  6. •
  7. Dj Equipment
  8. •
  9. Mark DecoPAR DPR36 User manual

Mark DecoPAR DPR36 User manual

Model No: DPR36 and DPR3612
TECHNICAL SPECIFICATIONS
Power Supply: 120V ~ 50-60Hz
Power consumption: 36 W
Dimensions LxWxH): 150 x 180 x 200mm / 6 x 7 x 7.9 in.
Weight unpacked): 1.4 kg / 3.1 lb.
Fitting lamp: 6V or 12V 30W PAR36 or AR111 Halogen lamp
Max. ambient temp. Ta: 25°C / 77°F
Max. housing temp. Ts: 90°C / 194°F
Min. distance: 0.5 m / 1.6 ft.
Manufactu e
Lamp Code Watts Volts Candlepowe
(Candela)
Colo
Temp (°K)
Field Angle
(Deg ees°)
Rated Life
(Hou s)
DecoPAR36 12 Volt Lamp Types
35AR111/SSP4
35AR111/SP8
35AR111/FL25
50AR111/SSP4
50AR111/SP8
50AR111/FL25
75AR111/SP4
75AR111/FL25
75AR111/WFL45
50PAR36/H/SP5
50PAR36/H/SP8
50PAR36/H/FL30
35
35
35
50
50
50
75
75
75
50
50
50
12
12
12
12
12
12
12
12
12
12
12
12
40,000
14,000
2,500
45,000
20,000
4,000
30,000
5,300
2,000
35,000
30,000
1,300
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
4,000
4,000
4,000
4°
8°
25°
4°
8°
25°
4°
25°
45°
5°
8°
30°
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,050
3,050
3,050
It is suggested that a glass shield be used with AR111 type lamps.
Manufactu e
Lamp Code Watts Volts Candlepowe
(Candela)
Colo
Temp (°K)
Field Angle
(Deg ees°)
Rated Life
(Hou s)
DecoPAR36 6 Volt Lamp Types
35AR111/SSP4/6V
4515
35
30
6
6.4
30,000
55,000
3,000
3,000
4°
5°
3,000
100
PAR 36 fixtu e with integ al 6 o 12 Volt magnetic
t ansfo me fo pin spot o AR111 lamps.
OPERATION:
Installation with Clamp
Select an appropriate clamp from your dealer to attach the fixture to a mounting pipe
e.g. truss system) and adjust the position of the fixture once it is mounted (Figu e 2).
1. Tightly fasten the clamp to the yoke with the provided
yoke bolt and lock washer.
2. Place the clamp on mounting pipe; tighten the pipe bolt
to secure it.
3. Loosen the clamp pan screw and rotate the yoke to the
desired position.
4. Tighten the pan screw to lock the fixture into position.
5. Adjust the desired inclination-angle via the yoke and
fix the yoke locking knob.
6. Always use appropriate safety cable.
Model No: DPR36 and DPR3612
IMPORTANT SAFETY INSTRUCTIONS
1. Prior to initial start-up, make sure that there is no shipping damage. Should there
be any, consult your dealer and do not use the device.
2. CAUTION! High voltage can inflict dangerous electric shock when touching
uninsulated wires! Keep away from heaters and other heating sources!
3. Do not mount the device on or near combustible surfaces.
4. Always install the device with the color frame retaining clip in the locked position.
5. This device falls under protection-class I, therefore it is essential that the yellow/green
conductor get connected to ground. The electric connection must be carried out by
a qualified person.
6. Make sure that the power cord is not crimped or damaged by sharp edges.
Periodically inspect the device and the power cord for damage.
8. If the external flexible cable or cord of this luminaire is damaged, must be exclusively
replaced by a qualified dealer.
9. Never let the power cord come into contact with other cables! Handle the power
cord and all connections with the mains with particular caution!
10. Always disconnect from the mains when the device is not in use or before cleaning
it. Only handle the power cord by the plug. Never pull out the plug by tugging the
power cord.
11. During the initial startup some smoke or odor may arise. This is a normal process
due to new paint and materials and does not necessarily mean that the device is
defective.
12. DANGER OF BURNS! Never touch the device during operation! The housing
heats up to max. temperature Ts) of 90°C / 194°F.
13. Do not switch the device on and off in short intervals as this will reduce the life span
of the lamp.
14. HEALTH HAZARD! Never look directly into the light source. Sensitive persons may
suffer an epileptic shock.
15. Children and inexperienced personnel should not operate this device.
16. There are no end-user serviceable parts inside the device. Maintenance and service
operations are only to be carried out by a qualified dealer.
Installing / Connection with the Mains
1. ELECTRICAL SHOCK HAZARD! The electric connection must only be carried
out by a qualified electrician!
2. In order to connect the device to the mains, a power-plug must be installed.
3. Configuration of connection-cables is as follows:
US
Cable Pin International
Black Live L
White Neutral N
Green Ground
IEC
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Ground
4. The ground must be connected!
5. Connect the device to the mains with the power-plug.
6. If the device will be directly connected with the local power supply network, a
disconnection switch with a minimum opening of 3 mm at every pole must be
included in the permanent electrical installation.
1. Disconnect the unit from power before installing the lamp.
WARNING! Let lamp cool before changing.
2. Remove the color frame from its holder (Figu e 1).
Note: To avoid premature lamp failure, do not touch the lamp glass with your fingers.
If you touch the lamp during installation, clean it carefully with 90% or better isopropyl
alcohol and a clean lint-free cloth before operation
3. Remove wire leads from screw terminals on back of old lamp. Connect wire leads
to replacement lamp screw terminals. Reinstall lamp in fixture.
4. Replace the color frame into the holder.
Installing the Iamp
Always replace the lamp if it becomes damaged or deformed.
Caution! perating lamps above their rated voltage reduces
lamp life and can cause premature lamp failure. For
installation, use one PAR36 lamp as specified in the lamp
table.

This manual suits for next models

1

Other Mark Dj Equipment manuals

Mark DecoPAR DPRC35E User manual

Mark

Mark DecoPAR DPRC35E User manual

Mark MMC 2000 User manual

Mark

Mark MMC 2000 User manual

Mark BEAM 198 MKII User manual

Mark

Mark BEAM 198 MKII User manual

Mark DecoPAR DPR30 User manual

Mark

Mark DecoPAR DPR30 User manual

Mark BEAM 350 User manual

Mark

Mark BEAM 350 User manual

Mark BEAM 190 User manual

Mark

Mark BEAM 190 User manual

Mark BEAM LED 150 User manual

Mark

Mark BEAM LED 150 User manual

Mark MRACK 12E User manual

Mark

Mark MRACK 12E User manual

Mark SUPERPARLED 136 User manual

Mark

Mark SUPERPARLED 136 User manual

Mark MOVILIGHT BEAM 150 User manual

Mark

Mark MOVILIGHT BEAM 150 User manual

Mark THEATRE 650 User manual

Mark

Mark THEATRE 650 User manual

Mark MOVILED 183 W User manual

Mark

Mark MOVILED 183 W User manual

Mark Superparled 355 IP User manual

Mark

Mark Superparled 355 IP User manual

Mark MINI BEAM 101 User manual

Mark

Mark MINI BEAM 101 User manual

Popular Dj Equipment manuals by other brands

Digital Juice Miniburst 128 user guide

Digital Juice

Digital Juice Miniburst 128 user guide

PROEL SG HDBEAM user manual

PROEL

PROEL SG HDBEAM user manual

Conrad Red disco laser operating instructions

Conrad

Conrad Red disco laser operating instructions

ProLights CROMOSPOT500 user manual

ProLights

ProLights CROMOSPOT500 user manual

PR XR 330 BEAM II product manual

PR

PR XR 330 BEAM II product manual

Denon MC4000 user guide

Denon

Denon MC4000 user guide

Cameo OPUS X PROFILE user manual

Cameo

Cameo OPUS X PROFILE user manual

TECshow FLATSIX user manual

TECshow

TECshow FLATSIX user manual

Elumen8 DB1300 user manual

Elumen8

Elumen8 DB1300 user manual

American Audio VELOCITY - REV 4-05 User guide and reference manual

American Audio

American Audio VELOCITY - REV 4-05 User guide and reference manual

UFO Sirius Series user guide

UFO

UFO Sirius Series user guide

Wild tech WT-KLD user guide

Wild tech

Wild tech WT-KLD user guide

Lightmaxx CLS-3 MKII user manual

Lightmaxx

Lightmaxx CLS-3 MKII user manual

involight SlimPAR644 user manual

involight

involight SlimPAR644 user manual

Panasonic KX-DT390 Quick reference guide

Panasonic

Panasonic KX-DT390 Quick reference guide

HERA PROLINE RGBA Series User manual & installation guide

HERA

HERA PROLINE RGBA Series User manual & installation guide

RASHA PROFESSIONAL ODLE COLOR LED BEAM 125 User instructions

RASHA PROFESSIONAL

RASHA PROFESSIONAL ODLE COLOR LED BEAM 125 User instructions

Lightronics FXLD157FRP6I2 owner's manual

Lightronics

Lightronics FXLD157FRP6I2 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.