1. Inspection
The following items are inside the box:
 User’s manual
 UPS
Remove Power UPS from its package and
inspect it for damage that may have occurred
during shipping. If any damage is discovered,
re-pack the unit and return it to the place of
purchase.
2. Place the UPS
Install this UPS in a
protected area that
is free of excessive
dust and provide
7.8-inch (20-cm)
clearance on sides for adequate airflow
around the unit.
 Avoid direct sunlight
 Avoid excessive heat
 Avoid excessive humidity or liquids
 Avoid excessive dust
3. Connect UPS to Utility
Use the power cord that came with your UPS
to connect the UPS directly to the wall outlet.
Battery Charging:
The UPS battery charges whenever the UPS
is connected to utility power and typically
requires less than eight hours to charge fully.
Operating runtime is reduced until the battery
is fully charged.
4. Connect Equipment to UPS
Connect the equipment to either, Battery
Power Supplied or Surge-protected outlets.
Battery Power Supplied Outlets :
Connect computer, monitor, and external
drive to the "Battery Power Supplied" outlets.
These outlets provide battery backup, EMI
filtering, line conditioning, and surge
protection. Battery power is automatically
provided in case of power failure. Ensure
Power Switch is kept in the "ON" position,
otherwise, the UPS will be disabled and your
equipment will not be protected during a
power failure.
CAUTION: DO NOT connect a printer or any
motorized products to any Battery Power
Supplied Outlet.
5. Turn On/Off
To turn on the UPS unit, press the power
switch lightly. To turn off the UPS unit,
press the power switch again.
6. Cold Start Function
When the UPS is off and there is no power
utility, it's still possible to cold start the UPS
unit to power the loads.
Power Switch
Press and release the button to supply power to the Battery Power
Supplied Outlets. Press and release the button again to switch off
power to the Battery Power Supplied Outlets.
UPS Status Indicator
AC Mode Indicator:
This green LED is lit when the UPS transfers utility power to both
Battery Power Supplied Outlets and Full Time Surge Protection
Outlets.
Battery Mode Indicator
This yellow LED flashes when the utility power is outside acceptable
limits and the battery supplies power only through the Battery Power
Supplied Outlets.
Battery Mode: sounding every 10 seconds
Low Battery: sounding every seconds
UPS fault Indicator
This red LED is lit when the UPS occur fault.
Overload: sounding every 0.5 seconds
Fault: continuously sounding
UPS INDICATORS & CONTROLS
Power Switch
UPS Status Indicator
AC mode: green lighting
Battery mode: yellow flashing
UPS fault: red lighting
USER’S MANUAL
POWER UPS
1100
/
1600
/
2200
 This UPS utilizes voltage that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user replaceable parts.
Only factory service personnel may perform repairs.
 This pluggable type A equipment with battery already installed by
the supplier is operator installable and may be operated by laymen.
 The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
 During the installation of this equipment it should be assured that
the sum of the leakage currents of the UPS and the connected
loads does not exceed 3.5mA.
 Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
 Connection to any other type of receptacle other than a two-pole,
three-wire grounded receptacle may result in shock hazard as well
as violate local electrical codes.
 In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to properly
disable the UPS.
 Do not allow any liquids or any foreign object to enter the UPS. Do
not place beverages or any other liquid-containing vessels on or
near the unit.
 This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive
contaminants). Avoid installing the UPS in locations where there is
standing or running water, or excessive humidity.
 Do not plug the UPS input into its own output.
 Do not attach a power strip or surge suppressor to the UPS.
 Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum
cleaners to UPS.
 To reduce the risk of overheating the UPS, do not cover the UPS'
cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space
heater or furnaces.
MODEL POW-1100A(S) POW-1600AS POW-2200AS
CAPACITY 1100VA/600W 1600VA/900W 2200VA/1200W
OUTLET
NUMBER
NEMA(120V) 6 8 8
IEC(230V) 4 6 6
INPUT
Voltage 110/115/120VAC or 220/230/240 VAC
Voltage
Range 81-145VAC or 162-290 VAC
Frequency 50/60 Hz (auto sensing)
OUTPUT
Voltage 110/115/120VAC or 220/230/240 VAC
Frequency
Regulation
(Batt. Mode)
60 Hz or 50 Hz ± 1 Hz
Waveform Simulated Sine Wave
BATTERY Battery Type
& Numbers 12V/7Ahx2 12V/9Ahx2 12V/9Ahx2
Backup Time Up to 60 min. Up to 85 min. Up to 90 min.
PROTECTION Full
Protection Discharge, overcharge, and overload protection
PHYSICAL Dimension
(DxWxH)
320 x 130 x 182 (mm)
12.6 x 5.1 x 7.2 (inch)
Net Weight 8.2 kgs
18.1 lbs
10.4 kgs
22.9 lbs
10.6 kgs
23.4 lbs
 Do not dispose of batteries in a fire as they may explode.
 A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when
working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
batteries terminal.
 Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell battery.
 Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required precautions.
Keep unauthorized personnel away from batteries.
 When replacing batteries, replace with the same number and type
of sealed lead-acid battery.
 Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes and may be toxic.
 Attention, hazardous through electric shock. Also with
disconnection of this unit from the mains, hazardous voltage may
still be accessible through supply from battery. The battery supply
should be therefore disconnected in the plus and minus pole at the
connectors of the battery when maintenance or service work inside
the UPS is necessary.
Battery Recycling Information
Your UPS contains non-spillable Sealed Lead Battery. On the battery,
you will find the battery name. Please reference below chart for
recycling information or contact your local distributor for assistance.
Battery Name Recycling inside the USA Recycling outside the USA
RITAR Battery (800) 273-8599 N/A
Problem Probable Cause Solution
No LED display
on the front
panel.
Low battery. Charge the battery at least 8
hours.
Battery fault. Replace the battery with
the same type of battery.
The UPS is not
turned on.
Press the power switch
again to turn on the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overloaded. Remove some loads first.
Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
When power fails,
backup time is
shorten.
The UPS is overloaded. Remove some critical load.
Battery voltage is too
low.
Charge the battery at least
8 hours.
Battery defect. It
might be due to high
temperature operation
environment, or
improper operation
to battery.
Replace the battery with
the same type of battery.
The mains is normal
but LED is flashing.
Power cord is loose. Reconnect the power cord
properly.
If any abnormal situations occur that are not listed above, please call
for service immediately.
Product Warranty and Service Information:
For U.S. customers, please register your product at www.MarusonUSA.com.
For international customers, please contact your local authorized distributor or
e-mail CustSrv@MarusonUSA.com for assistance.
Maruson Technology Corporation
1351 Titan Way, Brea, CA 92821, USA
P.O. Box 1986, Walnut, CA 91788, USA
Toll Free: 1-888-MARUSON
TEL: +1-714-870-6888
FAX: +1-714-870-4888
E-mail:Custsrv@MarusonUSA.com
Web Site: www.MarusonUSA.com
Safet
y
Caution
SAVE THESE INSTRUCTION-This manual contains important instructions for models
Power UPS 1100/1600/2200 that should be followed during installation and maintenance of the UPS and batteries.
Panel Information
Specification
*Specifications are subject to change without notice.
*Battery backup time based on basic PC and varies with equipment, configuration,
battery age, temperature, etc
Troubleshooting

This manual suits for next models

3

Other Maruson UPS manuals

Maruson Matrix VX33 Series User manual

Maruson

Maruson Matrix VX33 Series User manual

Maruson PowerMax User manual

Maruson

Maruson PowerMax User manual

Maruson POP-420B User manual

Maruson

Maruson POP-420B User manual

Maruson TAC-HV1K User manual

Maruson

Maruson TAC-HV1K User manual

Maruson Micro UPS Series User manual

Maruson

Maruson Micro UPS Series User manual

Maruson ULT-W1K User manual

Maruson

Maruson ULT-W1K User manual

Maruson SUR-809UPS User manual

Maruson

Maruson SUR-809UPS User manual

Maruson 1100 User manual

Maruson

Maruson 1100 User manual

Maruson Power Pro 650VA User manual

Maruson

Maruson Power Pro 650VA User manual

Maruson Ultima LiFe RT Series User manual

Maruson

Maruson Ultima LiFe RT Series User manual

Maruson 700 User manual

Maruson

Maruson 700 User manual

Maruson POF-800UA User manual

Maruson

Maruson POF-800UA User manual

Maruson CP-SV414-360W User manual

Maruson

Maruson CP-SV414-360W User manual

Maruson Tacoma II Series User manual

Maruson

Maruson Tacoma II Series User manual

Maruson PRO-650LCD User manual

Maruson

Maruson PRO-650LCD User manual

Maruson PRO- 650LCD User manual

Maruson

Maruson PRO- 650LCD User manual

Maruson ULT-1K User manual

Maruson

Maruson ULT-1K User manual

Maruson Power Pro 550VA User manual

Maruson

Maruson Power Pro 550VA User manual

Maruson PRO-400A LCD User manual

Maruson

Maruson PRO-400A LCD User manual

Maruson PowerPro 550VA User manual

Maruson

Maruson PowerPro 550VA User manual

Maruson TACOMA LV Series User manual

Maruson

Maruson TACOMA LV Series User manual

Maruson Tacoma HT 1K-3KVA User manual

Maruson

Maruson Tacoma HT 1K-3KVA User manual

Maruson PRO-550LCD User manual

Maruson

Maruson PRO-550LCD User manual

Maruson POF-800A User manual

Maruson

Maruson POF-800A User manual

Popular UPS manuals by other brands

DIGITAL UNDERDOG Blackjack Cube-LX quick start guide

DIGITAL UNDERDOG

DIGITAL UNDERDOG Blackjack Cube-LX quick start guide

Siemens SITOP DC UPS 6EP1931-2FC42 operating instructions

Siemens

Siemens SITOP DC UPS 6EP1931-2FC42 operating instructions

PowerWalker VFI 6000 TGB user manual

PowerWalker

PowerWalker VFI 6000 TGB user manual

PowerWalker VFI 6000T LCD L manual

PowerWalker

PowerWalker VFI 6000T LCD L manual

Tripp Lite SmartPro SMX1200XLHG Specification sheet

Tripp Lite

Tripp Lite SmartPro SMX1200XLHG Specification sheet

PowerGuard UQ11-RM user manual

PowerGuard

PowerGuard UQ11-RM user manual

Tripp Lite BC Pro owner's manual

Tripp Lite

Tripp Lite BC Pro owner's manual

TYCON Solar UPSPro UPS-ST-120 Quick install guide

TYCON Solar

TYCON Solar UPSPro UPS-ST-120 Quick install guide

PowerWalker VI 2000 LCD quick start guide

PowerWalker

PowerWalker VI 2000 LCD quick start guide

Tripp Lite SmartOnline SUINT1500LCD1U owner's manual

Tripp Lite

Tripp Lite SmartOnline SUINT1500LCD1U owner's manual

PowerWalker VI SCL Series quick guide

PowerWalker

PowerWalker VI SCL Series quick guide

Xtreme R91-20KVA User and installation manual

Xtreme

Xtreme R91-20KVA User and installation manual

Delta Ultron GES203HH33A035 user manual

Delta

Delta Ultron GES203HH33A035 user manual

MetaSystem ARCHIMOD 20 Operating and maintenance manual

MetaSystem

MetaSystem ARCHIMOD 20 Operating and maintenance manual

PowerWalker VI THID Series quick guide

PowerWalker

PowerWalker VI THID Series quick guide

Tripp Lite SmartPro RMX RMX 1000-2000 VA owner's manual

Tripp Lite

Tripp Lite SmartPro RMX RMX 1000-2000 VA owner's manual

PowerWalker VFI 10-200K CPT 3/3 manual

PowerWalker

PowerWalker VFI 10-200K CPT 3/3 manual

Tripp Lite SmartOnline SU3000RTXL3UHV Specifications

Tripp Lite

Tripp Lite SmartOnline SU3000RTXL3UHV Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.