9. Verify that the original green connector is not burnt and that
there are no black marks on it.
10. Connect the original green connector to the new PLC.
11. Reconnect the three wires to the 24v (white connector).
12. Power up the printer.
Replacing the Block PLC Hardware
From the Replacing the Machine PLC Hardware section, repeat
steps #1-12.
Updating the Block/Machine PLC Software
Burning a File into the PLC
¾Burn a File into the PLC:
1. Double click the ‘DVPServer’ application at C:\Program
Files\Matan Barak FE\Drivers\Delta to enter the
DVP_Tool.
2. Click OPEN to chose the desired *.DVZ file (BlockPLC.dvz or
MachinePLC.dvz) by double clicking it, as shown below.
3. Click WRITE TO PLC to open the COMMUNICATION SETTINGS dialog
box.
4. Configure the parameters in the COMMUNICATION SETTINGS dialog
box, and note the STATION ADDRESS and the COM PORT.
Both the Machine and Block PLC allocation is for the same
COM Port and it is set according to the Barak FE in the
ENGINEERING dialog box (Currently set to COM8).
10100142 - A © Matan Digital Printers Ltd. Page 4 of 8