Matrix Cogniface Integra 100E User manual

COSEC COGNIFACE INTEGRA Safety Instructions
These instructions are intended to ensure that the user can
use the product correctly to avoid danger or property loss.
Do not install the device:
•On unstable surface.
•Where ferromagnetic field or noise is induced.
•Where static is created, such as desks made of plastics,
carpets.
•Near volatile inflammable materials or inflammable goods such
as drapes.
•Where volatile gas and/or inflammable gas is created.
Cautions
•Installing and servicing should be done only by qualified
technician.
•There are no user-serviceable parts inside.
•Opening or removing the device cover may result in electric
shock or exposure to other hazards.
•Use the device only for the purpose for which it was designed.
Warning
COGNIFACE INTEGRA100
COGNIFACE INTEGRA200
11.19"

Contents
Please read this guide first for correct installation and retain it for future reference. The information
in this guide is prevailing at the time of publication. However, Matrix Comsec reserves the right to
make changes in product design and specifications without prior notice.
Copyright
All rights reserved. No part of this document may be copied or reproduced in any form or by any
means without the prior written consent of Matrix Comsec.
Warranty
Limited Warranty. Valid only if primary protection is provided, mains supply is within limit and
protected, and environment conditions maintained within product specifications. Complete
warranty statement is available on our website:
www.matrixaccesscontrol.com
Know your COGNIFACE INTEGRA
A COSEC COGNIFACE INTEGRA is an enclosure box which helps in maintaining
hardware elements to encourage Face Recognition feature for Time and
Attendance module through Matrix Devices. Here a COSEC device is integrated
with IP Camera for Face Recognition efficiently. It is available in two models:
COGNIFCAE INTEGRA100 and COGNIFCAE INTEGRA200.
4
4
Know your COGNIFACE INTEGRA
What your Package Contains
Things you will Need
8
Pre-Installation Safety Instrctions
Disposal of Product after End-Of-Life
Installation Instructions
Technical Specifications
Assigning IP Address and Other Network Settings
Preparing for Installation
7
7
13
27
28
29
8
1. Matrix IP Camera
2. COSEC Device - ARGO
3. Earthing Screw
4. ON/OFF Switch
5. Power Cable Slot
Variants
6. LAN Slot
7. Through Slot
8. Key Slot
9. Battery Compartment
Figure 1: Front View
7
1
2
4
3
5
6
7
8
9
Figure 2: Back View

COSEC Device - ARGO
•The Matrix ARGO device, is engineered with high-end wireless terminals for
Time & Attendance. Thus making it a best solution for providing Face
recognition feature when it is integrated with an IP Camera. The user image
captured by IP camera is processed by ARGO door to authorize the user for
Time and Attendance Management. Also, other credentials like Face/ Finger,
PIN and Card are supported by ARGO.
•COGNIFACE INTEGRA100 and COGNIFACE INTEGRA200 support different
COSEC ARGO devices they are as follows:
6
For providing efficient Face Recognition, IP Camera is used to capture user’s
image accurately. In COGNIFACE INTEGRA, Matrix IP Camera is used (Refer Figure
3). It is a Standard 2MP Dome Camera with Focal length of 2.8mm, mounted
above COSEC ARGO device at a suitable height in COGNIFACE INTEGRA. It
captures user image from the best angle. The captured image is used to identify
users for Time and Attendance Management.
Matrix IP Camera
Figure 3
The lens angle of camera is set at 15° downwards for obtaining best results.
COGNIFACE INTEGRA100
ARGO (FOE212/ FOM212/ FOI212)
ARGO (CAE200/ CAM200/ COM200)
Card
Sensing
Area
Touch
Screen
Display
Card
Sensing
Area
Touch
Screen
Display
COGNIFACE INTEGRA200
Finger
Sensor

Variants
The COSEC COGNIFACE INTEGRA100 and COGNIFACE INTEGRA200 have 3
variants each depending on type of ARGO device embedded as mentioned below:
Things you will Need
ŸPower Drill
ŸA Screw Driver
ŸCOSEC Software with FR license.
•Power Adapter 12VDC, 2A
•COSEC COGNIFACE INTEGRA device unit
•Screw Grips Plastic 8X35 - 4 Nos
•Screw M5X25 CSK PH - 4 Nos
•Mounting Template
•Earthing Cable
•EM Lock Cable
•External Reader Cable
What your Package Contains Pre-Installation Safety Instructions
1. Do not Install the device in extremely hot temperature or under direct sunlight
or at bright places. This may affect LCD and Card Sensor of the device.
2. Recommended height from ground to the top of the device is 1 cm for 15
best results.
3. Recommended distance between the IP Camera and the Face is 60 cm for
more effective face recognization.
4. Do not install on unstable surfaces, near volatile inflammable materials, area
where volatile gas is created, where ferro-magnetic field or noise is induced,
where static is created, such as desk made up of plastic or carpet.
5. Do not expose the device to extreme weather condition.
Preparing for Installation
Installation Process is same for both the COSEC COGNIFACE INTEGRA
models.Before Wall Mounting COSEC COGNIFACE INTEGRA, follow the
instructions given below:
Connecting Earthing Cable:
Remove the Earthing Screw with the help of screw driver and connect the
provided Earthing Cable in the slot.
To power COGNIFACE INTEGRA, plug-in the Adapter and connect the cable
into power cable slot and Switch ON the device. This will provide power to
all the devices: IP Camera, COSEC ARGO and FR Module in COGNIFACE
INTEGRA.
78
This is optional. If battery backup is needed, recommended Battery
Specification: 3.75V, 3000mAh to 5000mAh, Li-ion(Panasonic/ LG).
• COGNIFACE INTEGRA100E (ARGO CAE200)
• COGNIFACE INTEGRA100M (ARGO CAM200)
• COGNIFACE INTEGRA100I (ARGO CAI200)
COGNIFACE INTEGRA100 Variants
• COGNIFACE INTEGRA200E (ARGO FOE212)
• COGNIFACE INTEGRA200M (ARGO FOM212)
• COGNIFACE INTEGRA200I (ARGO FOI212)
COGNIFACE INTEGRA200 Variants
Battery Insertion

•After opening the battery compartment, place four battery cells in the space
given as shown in Figure 6.
•Remove the lid of battery compartment by unscrewing four screws with the
help of screw driver. Keep those screws aside carefully because they will be
required to fix the lid of battery compartment back into its position once the
battery cells are inserted. Open the Battery Compartment as shown in Figure 5.
910
Figure 5
Figure 6

Wall Mounting
Select a location. It must be a flat surface such as wall. Place the COGNIFACE
INTEGRA at specified height from the ground. There are two possible types of Wall
Mounting:
1. Key Slot Mounting
2. Through Slot Mounting
•Close the lid of the battery compartment as shown in Figure 7 and tighten
those four screws back into their position with the help of screw driver as
shown in Figure 8.
•In case of power cut, this will provide battery back-up for minimum 2 hours.
11 12
Figure 7
Figure 8
The Key Slot Mounting is recommended due to less complexity.

Installation Instructions
A) Key Slot Mounting
1. Place the mounting template against the wall where Installation is to be done.
Trace four screw holes using mounting template with pen/pencil as shown in
the Figure 9 and Figure 10 below.
14
13
Figure 9
Figure 10
70
279
282
109
123
146

15 16
2. Drill four screw holes(A,B,C,D) along the traced markings with the help of
power drill as shown in Figure 11 below.
3. Fix the supplied screw grips into the A, B, C and D screw holes as shown in
the Figure 12.
A
D
B
C
Figure 11 Figure 12
A
D
B
C

4. Insert screws into screw holes A, B, C and D having screw grips as shown in
the Figure 13 and Figure 14.
A
D
B
C
A
D
C
B
17 18
Figure 13
Figure 14

A
D
B
C
19 20
5. Align Key hole slots of COSEC COGNIFACE INTEGRA with the screws A, B, C
and D on the wall and slightly slide it downwards as shown in Figure 15 and
Figure 16.
Figure 15
Figure 16

B) Through Slot Mounting
Follow Steps-1,2,3 of Key Slot Mounting as initial steps for Through Slot
Mounting.
1. Place the mounting template against the wall where Installation is to be done.
Trace four screw holes using mounting template with pen/pencil as shown in
the Figure 9 and Figure 10.
2. Drill those four screw holes(A,B,C,D) along the traced markings with the help
of power drill as shown in Figure 11.
3. Fix the supplied screw grips into the A, B, C and D screw holes as shown in
the Figure 12.
4. Now unscrew the COSEC ARGO Device as shown in Figure 17.
22
21
Figure 17
Screw
5. Detach the Ethernet Cable and the DC Jack Cable of COSEC ARGO Device,
see Figure 18.
Ethernet Cable
DC Jack Cable
Figure 18

23 24
Figure 19
7. Unscrew the eight screws present on the Top Enclosure of the Device as
shown in Figure 20.
1
23456
7
8
Figure 20
6. Remove the COSEC ARGO Device as shown in Figure 19 and keep it aside
with caution.

26
25
8. Detach the two connections: Ethernet Cable, DC Jack Cable present at the
top and remove the Top Enclosure as shown in Figure 21.
Figure 21
9. Fix the four screws in the through slots of bottom enclosure. Tighten screw
1 in screw hole A, screw 2 in screw hole B, screw 3 in screw hole C and
screw 4 in screw hole D with the help of screw driver as shown in Figure 22.
1
2
3
4
Figure 22
DC Jack Cable
Ethernet Cable

10. After properly tightening the screws, close the enclosure box by fixing top
enclosure back into its position as shown in Figure 23. Tighten those 8 screws
back with the help of screw driver.
11. Before placing the ARGO Device back into its position, remember to plug-in
the Ethernet Cable and the DC Jack Cable correctly. Now tighten the screw
present at the bottom of the COSEC ARGO Device to fix it back into its position,
see Figure 24.
Figure 23
Figure 24

Battery Back-up Yes (upto 2 Hours)
User Capacity 50,000
Event Logs
5,00,000
Templates
Capacity
25000 (1:N mode) and 1 lakh (1:1 mode)
Built in Bluetooth
Input Power
12 VDC @2A
Yes BLE (4.2 and above)
0°C to +45°C
Type of Card
Technical Specifications
Operating
Temperature
COGNIFACE
INTEGRA100/200E
EM Prox Mifare/ Desfire/
NFC
Buzzer
Yes
Assigning IP Address and Other Network
Settings
For Face Recognition feature to work successfully, all the devices i.e COSEC
ARGO device, IP Camera and FR module must be in same network by default.
1. Consider the default IP Address of ARGO as: 192.168.50.1, default IP Address
of IP Camera as 192.168. 3 and default IP of FR module as: 192.168.50.2. 50.
2. Now once all the devices are connected online, add ARGO door in COSEC
software and assign the users.
3. Configure FR Settings on Door for the users.
27 28
1. Enable Face Recognition feature for the users from User Configuration.
2. Assign ARGO door to the users. Ensure that COSEC ARGO Door, FR Module
and IP Camera are in the same subnet.
3. On ARGO Door Device Configuration page, select the Capturing device as IP
Camera in Video Surveillance section. Configure the MJPEG URL of IP Camera in
Advance Settings.
4. For configuring FR Settings on ARGO Door, go to ‘Identification Server’ in
Device Configuration page of ARGO. Enable FR and select FR Mode as Local.
Enter the FR Server. After all settings are done, click on “Save”.
For more details, Refer COSEC User Guide.
Built in Wi-Fi Yes
COGNIFACE
INTEGRA100/200I
COGNIFACE
INTEGRA100/200M
Specification
Parameters
HID I CLASS/ HID
Prox/ EM Prox/
Mifare/ Desfire/ NFC
For Configuring FR
For Face recognition, there should be availability of platform and FR
Licenses.
Also check the supporting version of COSEC Server and COSEC Desktop
Utility- COSEC Enroll installed in computer.
Ensure all licenses are activated.
Weight 1.82 Kg (Approx)
Dimension Width: 193mm, Height: 311mm,
Diameter: 69mm(without dome)/ 114mm(with dome)
Credential Support
COGNIFACE INTEGRA100
COGNIFACE INTEGRA200
Face, PIN and RFID Card
Finger, PIN and RFID Card

The product refered is covered by the waste Electrical and Electronic
Equipment (WEEE) directive and must be disposed of in a responsible
manner.
At the end of product life cycle; batteries, soldered boards, metal
components and plastic components must be disposed through recyclers.
If you are unable to dispose-off the products or unable to locate e-waste
recyclers, you may return the products to Matrix Return Material
Authorization (RMA) department.
Disposal of Product after End-Of-Life
WEEE Directive 2002/96/EC
www.matrixaccesscontrol.com
Head Office
394-GIDC, Makarpura, Vadodara, Gujarat, 390010, India
Ph: (+91)1800-258-7747
Email: Suppor[email protected]
MATRIX COMSEC PVT LTD
V.1, April, 2021
29
FCC Compliance
This device complies with part15 of the FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits of Class A
digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
Warning
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
COGNIFACE INTEGRA200
COGNIFACE INTEGRA100
Product Compliance
FCC
This manual suits for next models
7
Table of contents
Other Matrix Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Intertec Data Systems
Intertec Data Systems SuperTerm Maintenance manual

Visara
Visara eterm 300 user manual

Tait
Tait TD9300 Installation and configuration manual

Festo
Festo VTUB-12-V Brief description

Tunstall
Tunstall ComTerminal Flamenco installation instructions

Mitsubishi
Mitsubishi G0T-A900 Series operating manual