MBW M300DP Instruction Manual

M300DP L Series Expansion I/O Module – Installation / User Manual
36 Copyright 2016 MBW Technologies, LLC All Rights Reserved
P/N: MN10058-00
AIt
Email: sales@mbwtech.com
Phone: (267) 932.8573 x340
www.mbwtech.com
MBW
Technologies
, LLC
Installation / User Manual
M300DP
Expansion I/O Module
for MBW L Series Control Panels
M300DP Expansion I/O Module
with AutoStart

M300DP L Series Expansion I/O Module – Installation / User Manual
2Copyright 2016 MBW Technologies, LLC All Rights Reserved
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved 35
MBW-Technologies, LLC (2 – Year) Limited Warranty
MBW Technologies, LLC (“MBW”) warrants its Electronic Module, Display
products, Electrical Cable and Electrical Connector products to be free from
defects in materials and workmanship for a period of two (2) years from the date
of shipment by MBW. Within this period, MBW will, at its sole option, repair or
replace any Electronic Module or Display that fails in normal use and is returned
to MBW (freight prepaid) within the warranty period. MBW is not responsible
for charges connected with the removal of such product or reinstallation of
replacement or repaired parts. This warranty does not cover failures due to abuse,
misuse, accident, faulty installation or unauthorized alteration or repairs.
THE EXPRESS WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
Statements made by any person, including representatives of MBW, which are
inconsistent or in conflict with the terms of this Limited Warranty, shall not be
binding upon MBW unless reduced to writing and approved by an officer of
MBW.
IN NO EVENT SHALL MBW BE LIABLE FOR ANY INCIDENTAL,
SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER
RESULTING FROM THE USE, MISUSE OR INABILITY TO USE THIS
PRODUCT OR FROM DEFECTS IN THE PRODUCT. Some states do not
allow the exclusion of incidental or consequential damages, so the above
limitation may not apply to you. MBW retains the exclusive right to repair or
replace the electronic module or display or offer a full refund of the purchase
price at its sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND
EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY.
Warranty Return Procedure:
To obtain warranty service, contact MBW Technologies, LLC Technical Support
problem and determine appropriate action.

M300DP L Series Expansion I/O Module – Installation / User Manual
34 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Index
A/S Mode............................................12
Block Diagram....................................21
DI1 and DI2 Function...................10, 14
Enter Button..........................................7
Escape Button.......................................7
Factory Installation
External Connections ...................20
Recommended Order....................19
Field Installation
Connections from A/S to Engine
Connector ...............................32
Connections from A/S to Keyswitch
................................................31
Connections from A/S to Throttle
Switch.....................................31
Make External Connections .........32
Recommended Order....................29
I/O Mode...............................................9
Installation
Connections from A/S to Display 31
Main Menu............................................7
Menu Navigation
Auto Start......................................25
Mode Button .........................................7
Operation
A/S Failure Alert ..........................17
Activate DI1 or DI2......................16
Enable A/S....................................16
Keyswitch Position.......................16
Schematic............................................22
Specifications......................................23
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved 3
Table of Contents
Quick Start Guide ....................................................................................................... 5
Powering the System .......................................................................................................... 6
Changing Data Displays ..................................................................................................... 6
MP300DP System Operation ................................................................................ 7
Menu Navigation .................................................................................................................. 7
M300DP Module Setup ...................................................................................................... 8
M300DP Modes ..................................................................................................................... 8
I/O Mode Operation .................................................................................................. 9
AI1 and AI2 Setup ................................................................................................................ 9
Speed 1 / Speed 2 RPM ...................................................................................................... 9
IO Status ................................................................................................................................ 11
Auto Start Operation ............................................................................................. 12
Analog Input Setup ........................................................................................................... 12
Start Retries ......................................................................................................................... 12
Start Delay(s) ...................................................................................................................... 12
Speed Settings .................................................................................................................... 13
Throttle Profile ................................................................................................................... 13
Digital Input Setup ............................................................................................................ 14
IO Status ................................................................................................................................ 15
Activating AutoStart ......................................................................................................... 15
Typical Auto Start Application .......................................................................... 18
Installing Control Panel with Expansion I/O .............................................. 19
Making the Connections ................................................................................................. 19
Engine Connector .............................................................................................................. 21
Wiring Diagram ....................................................................................................... 22
Technical Specifications ....................................................................................... 23
System Components .............................................................................................. 23
Default Settings ........................................................................................................ 24
Appendix A - Menu Overview ............................................................................ 25
Troubleshooting Guide ......................................................................................... 28
Appendix B – Field Installation ......................................................................... 29
Making the Connections ................................................................................................. 29
Connection Details ............................................................................................................ 33
Mechanical Mounting ...................................................................................................... 33
Updating Display Software............................................................................................ 33

M300DP L Series Expansion I/O Module – Installation / User Manual
4Copyright 2016 MBW Technologies, LLC All Rights Reserved
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
33
Connection Details
Connector Description
P4 6 Pin; connects to , black housing
S1 6 Pin; connects to P1r, grey housing
CAN Yellow & Green wires
Oil Pres, Fuel Analog Inputs - Orange, Green/Black wires
DI1 / DI2 Discrete Inputs - White/Black, White, Black
Common Common – connects to Throttle Switch, Black
Mechanical Mounting
The Auto Start module has two mounting holes 0.18 Diameter or # 8
screws. The mechanical dimensions are shown in the figure.
Updating Display Software
In order for the display to recognize the Auto
Start module, the display software must be
revision v2.00 or higher. Go to the System Menu
and scroll down to ABOUT M154. Hold MODE to
view the software version screen. When the Auto
Start module has been installed, the SW Version for the M300DP will also
be displayed.
If your software needs updating, contact your local distributor for the latest
software revision.

M300DP L Series Expansion I/O Module – Installation / User Manual
32 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Insert Auto Start Leads into the Engine Connector
The Auto Start module provides six wire leads from the module to support
two analog inputs, two discrete inputs and an alarm. These leads must be
inserted into the P1 connector. The recommended pin locations are
shown in the table below.
Make External Connections
To connect the two analog signals and the two discrete inputs to the
device(s), five pigtails are provided and must be inserted into the Engine
harness. The recommended pin locations are shown in Table 4.
The installer is responsible for making the connection from each pigtail to
the device(s) (Oil Pressure Sender, Fuel Sender, Float Switch, etc.).
Figure 3. Engine Connector Pigtails
Alternate Connection
Although the installation instructions show the analog and discrete inputs
going to the 21 pin engine connector they could also be grouped together
on a separate 6 pin connector (DT04-6S).
Existing Engine Harness
Make connections to Senders
and Float Switch
Insert six Auto Start pigtails into
the engine connecto
r
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
5
Quick Start Guide
Navigation
Keypad
Throttle
Increment /
Decrement
Key Switch
RPM Gage
Controller
Display
10A Resettable
Circuit Breaker
System ICONS

M300DP L Series Expansion I/O Module – Installation / User Manual
6Copyright 2016 MBW Technologies, LLC All Rights Reserved
Powering the System
The M300DP Expansion I/O control module is a dual mode system and
can be programmed for either Auto Start (A/S) or expansion I/O capability.
The M300DP can be used with all M150B and M150L Series Control
Panels.
To power the system turn the key switch to the “ON” position. This will
activate the control panel and apply power to the M300DP module and the
engine ECU. Should the control panel indicate a fault condition review the
M150 Series manual for details and correct the condition before starting
the engine.
On a successful power up sequence, the system will display the currently
configured default display. The factory default display is Engine Speed.
Changing Data Displays
To change the data being displayed press the “▼” or “▲” buttons to
access additional data displays.
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
31
Connect the Auto Start Module to the Display
The following four steps provide the detailed modifications to the control
panel harness required for the Auto Start module.
1. Remove the wedgelock and the Yellow wire from the P3
connector and insert the Yellow wire from the Auto Start module
into the vacated pin location (Pin 3).
2. Remove the Green wire from the P3 connector and insert the
Green wire from the Auto Start module into the vacated pin
location (Pin 4).
3. Re-install the wedgelock and plug the P3 connector into the
display.
Connect the Auto Start Module to the Keyswitch
The following four steps provide the detailed modifications to the control
panel harness required for the Auto Start module.
1. Remove the P1 connector from the keyswitch and install the P4
connector of the Auto Start module into the keyswitch.
2. Remove the wedgelock and insert the Yellow wire removed from
the display connector into pin 6 of the P1 connector.
3. Insert the Green wire removed from the display connector into
pin 3 of the P1 connector.
4. Re-install the edgelock and plug the P1 connector into the S1
connector of the Auto Start module.
Connect the Auto Start Module to the Throttle Switch
The following steps provide the detailed modifications throttle switch.
1. Remove the black wire from the throttle switch and install the
black wire with 1/4 “ quick disconnect.
2. Re-install black throttle wire onto the piggyback terminal.
Figure 2. Throttle Switch Connection
Black throttle switch wire plugged
into piggyback terminal.

M300DP L Series Expansion I/O Module – Installation / User Manual
30 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Re-Assemble
9. Mount the Auto Start module.
10. Connect the control panel connector (HDP24-21 connector) to the
engine harness.
11. Re-install the control panel.
12. Connect battery.
13. Turn ignition key to “ON” position.
14. Ensure digital display is active. If display is not active;
a. Check battery and power connections.
b. Check ignition switch is on position.
15. Ensure system is displaying data for engine speed, oil pressure
and temperature.
Figure 1. Expansion I/O Module
Insert Yellow wire into P3-3 &
Green wire into P3-4
S1
P4
Insert six wires into
engine connector
Connect Black wire to
throttle switch
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
7
MP300DP System Operation
Menu Navigation
The Mode Button is multi-functional and is used as an escape and enter
key. When the Mode key is pressed for less than 1 second it is considered
an escape action. When pressed for greater than 1 second is considered
an enter function. For example, to enter a menu selection or save an
entered value the button must be pressed and held for greater than 1
second. When escaping a menu selection, momentary Mode Button
presses are used. The only exception to these actions is entering the
main menu. From any runtime data display screen a momentary press of
the Mode Button will activate the main menu.
Main Menu
The Main Menu allows the user to access all areas of the M150L Control
System. To access the Main Menu press the Mode button. To access
menu items highlight the desired selection using the “▼” or “▲” keys and
press & hold the MODE for 1 second.

M300DP L Series Expansion I/O Module – Installation / User Manual
8Copyright 2016 MBW Technologies, LLC All Rights Reserved
M300DP Module Setup
To access the M300DP menu, press on the MODE
key to view the Main Menu. Press the “▼” or “▲”
keys until “M300DP Module” is highlighted. Press
and hold MODE > 1 second to enter the M300DP
submenu.
NOTE: The M300DP Module menu selection will only be visible if the
M300DP is correctly installed and has CANbus communication with the
M150L series display.
M300DP Modes
The M300DP has three modes which determine how the module operates
as well as the structure of the M300DP menu within the display.
OFF: AutoStart functionality is disabled.
Configurable digital inputs are disabled. The two
additional analog inputs are still available and are
a shared setting between all three modes.
I/O: Two configurable DI’s can be set as engine
stop, start, inhibit, or programmable speed
inputs. Analog inputs remain the same. No
autostart functionality.
A/S: Autostart mode uses the DI’s to
automatically start and stop the engine while key
switch is in the “Auto” position. A customizable
three speed throttle profile controls the engine
speed during startup and shutdown.
To view the current
M300DP Mode, press and
hold the MODE key > 1
second while the MODE
selection is highlighted. To
change the mode, use the “▼” or “▲” keys to highlight the desired mode.
Press and hold the mode key to save and confirm the change.
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved 29
Appendix B – Field Installation
Making the Connections
The Expansion I/O Module shown in Figure 1, has two floating connectors
(P4 and S1), 6 wire leads to be connected to the Engine connector, one
black lead with a piggyback quick disconnect which goes to the throttle
and two leads (Yellow and Green) which go to the .
Also provided are six 6” pig tails (White w/Blue, Orange, Green w/Black,
White, White w/Black and Black) which can be used on the engine side of
the engine connector to make remote connections to analog and discrete
inputs.
Recommended order:
1. Verify the battery / battery switch connections to engine per the
engine installation diagram. (Refer to engine manufacturer
installation manual.). Verify engine is bonded to battery return (-).
Verify engine block is connected to battery ground.
2. Disconnect battery.
Control Panel Modifications
3. Loosen the four screws (3/32 Hex) and remove the control panel
from the housing base. Disconnect the control panel from the
engine harness (HDP24-21 connector).
4. Make connections from the Auto Start module to the display.
MORE DETAIL IN NEXT SECTION
5. Make connections from the Auto Start module to the keyswitch
6. Make a connection to the throttle switch
7. Insert the 6 wire leads from the Auto Start module into the 21 pin
engine connector (HDP24-21 connector).
Engine Harness Modifications
8. Make external connections to the Oil Pressure Sender, Fuel
Sender, Digital Input 1, Digital Input 2 and Common to the 21 pin
Deutsch connector of the engine harness using the five 6” pigtails.

M300DP L Series Expansion I/O Module – Installation / User Manual
28 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Troubleshooting Guide
Symptom Action
The M300DP Menu Selection does not
show up in the Main Menus
Check the Yellow and Green wires from the
A/S Module and the Display
Check the keyswitch connection (Black
Wire)
Make sure the M150 Series software
version is version 2.0 or higher.
Engine does not crank when keyswitch is
in normal Start position
Check pin D (i.e., Start) connection to the
Engine Connector.
Engine cranks but does not fire when
keyswitch is in normal Start position
Check Engine manual for troubleshooting
start issues.
Auto Start ALERT not displayed when
keyswitch set to Auto Start (Full
Counterclockwise position) .
Check the settings to make sure the mode
is set to A/S
With a discrete input set to Start/Stop, the
Auto Start Alert screen is displayed but
turns off and then on again
Make sure the On Delay set for the discrete
input are longer than the time the discrete
input is bouncing.
Engine running but shuts down
unexpectedly; then restarts.
Make sure the Off Delay set for the discrete
input are longer than the time the discrete
input is bouncing.
The auto start countdown does not start
when the discrete input is activated
Make sure DI1 and DI2 are correctly set for
Start and Stop
Make sure the Active State for DI1 and DI2
are set correctly
Make sure the discrete input wires are
inserted into the correct pin locations of the
Engine Connector.
The data for the senders on to an analog
input does not show up as an Engine
parameter.
Make sure the analog input wires are
inserted into the correct pin locations of the
Engine Connector.
The data for the senders connected to an
analog input shows up on the Engine
display but the values are wrong
Make sure the sender selection for the
analog input are set to the correct sender
option (US versus Euro)
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
9
I/O Mode Operation
Input / Output Mode (I/O Mode)
Selecting I/O disables the Auto Start Feature but
allows the DI1 and DI2 inputs to be used as I/O.
The AI1 and AI2 analog inputs will be active.
AI1 and AI2 Setup
The M300DP Module has two analog inputs which may be configured for
a number of senders. When the analog sender has been connected and
the setup complete, the corresponding screen will be added to the rotating
display list.
Off
Fuel US (240-33 ohms)
Fuel Euro (10 – 180 ohms)
Water Level US (240-33 ohms)
Water Level Euro (10- 180 ohms)
Use the “▼” or “▲” keys to highlight the desired sender type. Press and
hold mode to save the selection or quick press mode to discard any
changes.
Speed 1 / Speed 2 RPM
The I/O Mode supports the setup of two different engine RPMs. These
speed settings are bounded by the MIN / MAX RPM in the Engine menu.
When a DI configured as Speed 1 or Speed 2 is activated the display will
command the engine to the configured RPM.
Use “▼” or “▲” keys to set Speed 1 RPM or Speed 2 RPM.

M300DP L Series Expansion I/O Module – Installation / User Manual
10 Copyright 2016 MBW Technologies, LLC All Rights Reserved
DI1 and DI2 Setup
The DI1 Setup and DI2 Setup are used to program the operation of the
two discrete inputs.
DI1 and DI2 Function
The DI1 or DI2 inputs are used to control the engine and may be
configured as Off, Stop, Speed1, Speed2 or Start Inhibit (Start Inh) as
defined in Table 1.
.
NOTE: When the DI1 and DI2 inputs are setup as speed inputs, DI2 has
priority over DI1 regardless of whether it has been configured to Speed 1
or Speed 2. The throttle switch has priority over both DI1 and DI2.
Table 1 - DI1 and DI2 Setup
Stop - When configured to Stop, DI1 or DI2 will stop the engine.
Speed 1 - When configured to Speed 1, DI1 or DI2 will ramp the
engine to the Speed 1 setting.
Speed 2 - When configured to Speed 2, DI1 or DI2 will ramp the
engine to the Speed 2 setting.
Start Inh - When configured to Start Inh (Start Inhibit), the engine will
not start while the configured DI is active.
OFF – Disables the discrete input
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
27
M300DP Main Menu – con’t

M300DP L Series Expansion I/O Module – Installation / User Manual
26 Copyright 2016 MBW Technologies, LLC All Rights Reserved
M300DP Main Menu – con’t
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
11
Active State
The DI1 and DI2 inputs may be set for an input device that has either a
Normally Open (N.O.) or Normally Closed (N.C.) contacts. The active
state for a N.O. switch is “Closed” (closure to ground) and the active state
of a N.C. switch is “Open”.
Use the “▼” or “▲” keys to highlight desired active state. Press and hold
MODE key to save selection.
On Delay (s)
The On Delay parameter controls how long (0 to 60.0 seconds) the active
state is present before action is taken.
Use the “▼” or “▲” keys to adjust delay time. Press and hold MODE key
to save changes.
Off Delay (s)
The Off Delay parameter controls how long (0 to 60.0 seconds) the
inactive state is present before action is taken.
IO Status
IO Status is a diagnostic screen. The IO Status
display provides the Mode, the status of the two
digital inputs and the raw ADC counts for the two
analog inputs. AS provides the status of the
keyswitch: Auto position = 1, On position = 2,
Start position = 3.
An Analog input value of 0 indicates the input is shorted. A value of 1023
indicates the input is open.

M300DP L Series Expansion I/O Module – Installation / User Manual
12 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Auto Start Operation
Auto Start Mode (A/S Mode)
Selecting the A/S Mode allows the DI1 and/or
DI2 discrete inputs to start and control the
engine. The AI1 and AI2 analog inputs will be
also active.
Analog Input Setup
The M300DP Module has two analog inputs
which may be configured for a number of
senders:
Off
Fuel US (240-33 ohms)
Fuel Euro (10 – 180 ohms)
Water Level US (240-33 ohms)
Water Level Euro. (10- 180 ohms)
When the sender has been connected and the
setup complete, the sender data will appear on
the engine display along with the other engine
parameters. Use the “▼” or “▲” keys to
highlight the desired sender type. Press and
hold MODE key to save changes.
Start Retries
The number of engine start cycles to be
executed after the initial AutoStart (A/S)
sequence is enabled and activated. A start cycle
is 10 seconds of cranking followed by a 5
second wait. The number of start retries can be
configured for 0 to 3 retries. When configured for
0 retries the engine start cycle will activate one time only, on the initial
Auto Start command.
Start Delay(s)
The time (seconds) from the activation of a start
input to the time engine cranking begins. This
time will appear as a countdown on the display.
(0 – 30 seconds). Use the “▼” or “▲” keys to
adjust delay. Press and hold MODE key to
save.
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
25
Appendix A - Menu Overview
M300DP Main Menu

M300DP L Series Expansion I/O Module – Installation / User Manual
24 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Default Settings
Upon receiving the Auto Start module, the unit will be set to the following
values. Setting the module back to defaults is made by using the
RESTORE DEFAULTS which is under the ENGINE SETTINGS menu
level.
Parameter Default Value
Display Settings
M300 Mode OFF
Speed 1 Engine Min RPM
Speed 2 1500 RPM
Speed 3 Engine Max RPM
Throttle Profile
Speed1 (s) 5
Speed1 Ramp (s) 5
Speed2 (s) 5
Speed2 Ramp (s) 5
Speed3 (s) 5
Stop (s) 5
DI1 Setup OFF
DI2 Setup OFF
AI1 OFF
AI2 OFF
A/S Delay (s) 10
Start Retries 0
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
13
Speed Settings
The A/S Mode supports three different engine speed settings. These
settings can be used in the throttle profile and in the remote speed
assignments. The speed values (RPM) may be programmed from 600 to
3150 in increments of 50 RPMs. Speed 1, 2, and 3 are bounded by the
Engine MIN/MAX RPM range in the Engine menu.
(Note: range of rpm settings may vary based on engine model.)
Use the “▼” or “▲” keys to set the RPM for Speed 1, 2, and 3. Press and
hold MODE key to save each selection.
Throttle Profile
When the AutoStart input is activated, a Throttle Profile is used to control
the engine speed over a series of steps. The profile has 5 settings which
are described in Table 2 below. Use the “▼” or “▲” keys to set the
desired time for each stage of the Throttle Profile. Press and hold MODE
key to save each selection.
Note: If a Throttle Profile Segment time is set to zero, that segment of the
profile will be skipped.
Table 2 - Throttle Profile Setup
Speed1 (s) – This parameter determines how many seconds the engine
will run at Speed1.
Ramp->Speed2 (s) – This parameter determines the ramp time from
engine Speed 1 to Speed 2 in seconds.
Speed2 (s) – This parameter determines how many seconds the engine
will run at Speed2.
Ramp->Speed3 (s) – This parameter determines the ramp time from
engine Speed 2 to Speed 3 in seconds.
Ramp->Min (s) – This parameter determines ramp time from current
speed to the Min RPM value in Engine menu.

M300DP L Series Expansion I/O Module – Installation / User Manual
14 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Digital Input Setup
The DI1 and DI2 Setup
Menus are used to program
the operation of the two
discrete inputs.
Digital Input Functionality
The digital input functionality must be configured
and a wide range of selections are made available
to the user providing the flexibility to match their
specific application. These inputs should be
configured before activating the system. First the
functionality of the digital input must be configured.
The choices are; “Off”, “Start”, “Stop”, “Start/Stop”,
“Speed 1”, “Speed 2”, “Speed 3” and “Start Inhibit”
(Start Inhibit) as defined in Table 3.
Use the “▼” or “▲” keys to highlight the desired function. Press and hold
MODE key to save changes.
Table 3. Digital Input Functionality
OFF – Disables the discrete input
Start – When configured to Start, DI1 or DI2 will be used to Start the engine.
Stop - When configured to Stop, DI1 or DI2 will be used to Stop the engine.
Note: For safe operation in A/S mode be sure to set one DI to a setting of
“Start/Stop” or “Stop”.
Start/Stop - When configured to Start/Stop, DI1 or DI2 will be used to Start the
engine when the active state occurs and then Stop the engine when active state
goes inactive.
Speed 1 - When configured to Speed 1, DI1 or DI2 will ramp the engine to the
Speed 1 setting.
Speed 2 - When configured to Speed 2, DI1 or DI2 will ramp the engine to the
Speed 2 setting.
Speed 3 - When configured to Speed 3, DI1 or DI2 will ramp the engine to the
Speed 3 setting.
Start Inh - When configured to Start Inh (i.e., Start Inhibit), the engine will not start.
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved 23
Technical Specifications
Parameter Specification
Operating Voltage 9 to 32 VDC
Communication J1939 CAN 2.0B
Operating Temperature -30C to +70C (-22F to 158F)
Storage Temperature -40C to +80C (-40F to 176F)
Reverse Polarity Protection Yes
Salt Spray
IEC60068-2-52: 19960.18 Dia or #
8 screw
No Tests Performed
EMC IEC61000 and EN55022
No Tests Performed
Degree of Protection IP67
Dimensions 102.294mm x 53.39mm x 27.3mm
(4.053” x 2.102” x 1.075”)
System Protection Provided externally
System Components
Part Number Description
M300DP Expansion I/O Module
/AS Add M300DP to any M150B or M150L Series product
MN10036 Manual – User M154L Yanmar T4F
MN10047 Manual – M300DP Expansion I/O Control for B Series Panels
MN10058 Manual – M300DP Expansion I/O Control for L Series Panels
MN10060 Data Sheet – M300DP Expansion I/O for L Series Panels

M300DP L Series Expansion I/O Module – Installation / User Manual
22 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Wiring Diagram
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
15
Active State
Each digital input can be configured to determine its active state. This
allows the user to set the digital input for an input device that has either a
Normally Open (N.O.) contact or a Normally Closed (N.C.) contact. The
active state for a N.O. switch should be set to “Closed” (closure to ground)
and the active state of a N.C. switch should be set to “Open” (input is
open).
On/Off Delay (s)
The On/Off Delay parameters control how long the active and inactive
states must be stable before action is taken. The settable range for these
parameters is 0.0 to 60.0 seconds.
IO Status
The IO Status Display is provided for diagnostic purposes. This screen
provides information about the status of the M300DP provides the Mode,
the status of the DI1 and DI2 inputs and the counts for the AI1 and AI2
inputs. AS provides the status of the keyswitch: Auto =1, On =2, and
Start=3

M300DP L Series Expansion I/O Module – Installation / User Manual
16 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Activating AutoStart
To activate the Auto Start Sequence:
•Enable Auto Start mode
•Configure start and stop DI’s and Throttle profile.
•Set the keyswitch is in the “Auto” position
•Activate the DI1 or DI2 inputs configured for Start.
Enable Auto Start Mode
To use the Auto Start feature the M300DP Mode must be set to A/S. See
the section on M300 Setup.
Set the Keyswitch in the “Auto” Position
When the ignition switch is placed in the “Auto”
position (keyswitch in a fully counter-clockwise
position) an ALERT will be displayed on the
main engine display. This window will display for
approximately 1 minute. The system will then
enter a power save mode, waiting for the
AutoStart input to activate.
NOTE: If the ignition switch is in the “ON” position the AutoStart feature
will not activate.
Activating the AutoStart input
There are two discrete inputs, DI1 and DI2,
which may be used to initiate an Auto Start
sequence. See the Installation section of this
manual for more information.
Selecting “A/S” enables
the AutoStart Mode
Note: A/S is not activated until
key switch is in Auto Position.
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
21
Engine Connector
The engine connector is labeled “Engine” and must be modified to support
the Auto Start module. This connector mates directly to the on-engine
harness connector.
Table 4. Engine Connector Pin Definitions
Signal PIN
Number
Engine Harness
Connector – P2
Contact
Size
Wire
Color
Alarm A
M300DP – Alarm
(Switch Closure to
ground LO-2 Amp Max)
16 White/
Blue
B+ B Battery + (10A) 12 Red
AI1 C M300DP AI1 16 Orange
Start D Starter (30) 12 Red/Black
Ground E Ground 12 Black
Ignition
Out G ECU Power (Ignition) 12 Violet
DI2 H M300DP DI2 16 White
Controller
Power J ECU Key On 16 Purple
DI1 K M300DP DI1 16 White/Blue
AI2 L M300DP AI2 16
Green/
Black
DI
Common M M300DP DI Common 16 Black
Fuel N Fuel Sender 16
Green/
Black
Oil Press P Oil Press Sender 16 Orange
Charge In R Charge Lamp 16 Dark Green
CAN Lo U CAN Low (twisted pair) 16 Light Green
CAN Hi V CAN High (twisted pair) 16 Yellow
Shutdown X External Engine Stop 16 Blue
No
Connection
A, F,H,K,L,M,
S,T,W
.

M300DP L Series Expansion I/O Module – Installation / User Manual
20 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Make External Connections
To connect the two analog inputs and the two discrete inputs to the
sender(s), five pigtails are provided and must be inserted into the Engine
harness. The recommended pin locations are shown in Table 4.
The installer is responsible for making the connection from each pigtail to
the device(s) (Oil Pressure Sender, Fuel Sender, Float Switch, etc.).
Figure 3. Engine Connector Pigtails
Existing Engine Harness
Make connections to
Senders and Float Switch
Insert six Auto Start pigtails
into the engine connector
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
17
When the Auto Start input is activated, the M150L Series will exit the
power save mode and indicate an impending engine start sequence by
generating a countdown sequence to engine start. If the system has been
wired for an alarm, an audible alarm will be heard during this time. See
the Installation section of this manual for more information.
Starting the Engine
Once the countdown is complete the module will
activate the start input to the engine. The
screen will read “ENGINE START NOW” and
the starter will remain active for 10 seconds or
until the engine is running. If the engine does
not successfully start during this time the starter
will turn off.
Once Auto Start has been activated the display
will switch to the Requested Speed screen and it
will reflect the engine speed and ramp times
programmed in the Throttle Profile. See the
section on setting the Throttle Profile.
Auto Start Failure
If the engine fails to start after the initial 10
seconds and the configured retries, the display
will show the “Autostart Failed” screen. At this
point the operator will need to cycle the key
switch before the M300DP module will attempt
to start the engine again.

M300DP L Series Expansion I/O Module – Installation / User Manual
18 Copyright 2016 MBW Technologies, LLC All Rights Reserved
Typical Auto Start Application
M300DP L Series Expansion I/O Module – Installation / User Manual
Copyright 2016 MBW Technologies, LLC All Rights Reserved
19
Installing Control Panel with Expansion I/O
Making the Connections
The control panel has one round connector with 21 contacts. This
connector is an HDP24 Deutsch connector and provides the connection to
the engine connector. (Note: Some engines may require an interface
harness for this connection. Contact MBW Technical Support Team for
details.) The supply power MUST be OFF when interconnecting the
system.
Recommended order:
1. Verify the battery / battery switch connections to engine per the
engine installation diagram. (Refer to engine manufacturer
installation manual.) Verify engine is bonded to battery return (-).
Verify engine block is connected to battery ground.
2. Disconnect battery.
3. Make external connections to DI1, DI2, AI1, and AI2.
4. Install control panel into the housing. Attach engine connector to
housing using supplied locknut and ring.
5. Fasten control panel to housing using #8 8-32 screws (not
supplied).
6. Connect engine harness connector to mating control panel
connector (HDP24-21 connector).
7. Connect battery.
8. Turn ignition key to “ON” position.
9. Ensure digital display is active. If display is not active;
a. Check battery and power connections.
b. Check ignition switch is on position.
10. Ensure system is displaying data for engine speed, oil pressure
and temperature.
Table of contents
Popular Control Unit manuals by other brands

Robostar
Robostar N1 Series Option DeviceNet manual

Anderson
Anderson Greenwood Series Installation and maintenance instructions

SKF
SKF SMBM-X Series Assembly instructions

Ring Engineering
Ring Engineering AM-1b user manual

Comunello
Comunello CU 230V HP Installation and user manual

Murata
Murata LBAA0QB1SJ user manual

Allen-Bradley
Allen-Bradley ControlLogix 1756-OX8I installation instructions

ThaiEasyElec
ThaiEasyElec MP3 user manual

Amphenol
Amphenol SGX SNSORTECH PS1-O3-5-MOD Data Sheet / Manual

Honeywell
Honeywell PRO4200 installation guide

Pickering
Pickering 41-760 user manual

Panasonic
Panasonic PAN9026 Developer's guide