Fan Coil Thermostat (2-pipe)
MH8S-FC-EU
Introduction n
MCOHome Fan Coil Thermostat is a Z-Wave enabled device for indoor temperature control.
It is mainly applied to a 2-pipe Fan coil system. It can read room temperature and local time, and
automatically control fan speed based on the temperature difference. The device is of high reliability
and practicability. This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from any other manufacturers.
Features:
Capacitive touch buttons
Tempered glass panel, PC alloy enclosure
Precise temperature calibration function
Non-volatile Memory, working state saved even power failure
Intelligent on/off control of 3-speed fan, electric (ball) valve or air-valve
Easily steel frame back plate installation
Specification n
Power Supply:AC24V, 50/60Hz
Resistive Load: ≤3A
Self Consumption:< 1W
Temperature Sensor: NTC 15K
Display Accuracy: 0.1 ℃
Working Environment:0~55℃; <95%
RH(Non-condensation)
Temperature Setting :5~35 ℃
(Adjustable)
Dimension:86* 86*42mm
Hole Pitch :60-65mm (86 Standard
junction box)
Z-Wave Frequency: 868.42MHz (EU)
Safety Information n
To protect yourself and others from danger and to protect the device from damage, please read the
safety information before using it.
Important!
A qualified electrician with the understanding of wiring diagrams and knowledge of electrical
safety should complete installation following the instructions.
Before installation, please confirm the real voltage complying with the device’s specification.
Cut off any power supply to secure the safety of people and device.
During installation, protect the device from any physical damage by dropping or bumping. If
happens, please contact the supplier for maintenance.
Keep the device away from acid-base and other corrosive solids, liquids, gases, to avoid damage.
Avoid overexertion during operation, to protect device from mechanical damage.
Read all instructions and documentation and save for future reference.

User Manual
MCOHome Technology Co., Ltd www.mcohome.com
2
Installation & Wiring g
Location:
Thermostat is suggested to be installed indoor, a place with around 1.5m height above the floor
where represents the average room temperature. It should be away from direct sunlight, any cover, or
any heat source, to avoid false signal for temperature control.
CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock
Or death!
Step 1: Remove the steel frame from the device, and secure it
onto the junction box with two screws.
Step 2: Insert all wires into the right terminals and tighten
screws. The wiring diagram is shown below.
Step 3: Attach the wired device on “A” points of the steel frame
as shown first, and then push the whole device into junction box.
Step 4: Confirm the device is well mounted, power on and it is
ready to operate.
Button & Display y

User Manual
MCOHome Technology Co., Ltd www.mcohome.com
3
Operation n
On/Off Setting
When power on, thermostat will display“OFF”,press to enter working interface.
When normal working, press to turn off the device,“OFF”displays and all outputs are off.
Local Time Setting
Press & hold “M” to enter local time setting. Touch “M” to switch among Week, Hour & Minute,
and then press or to set the parameters of flashing item. Press“M”,or wait for 15s to save the
value and return to display.
Working Mode Setting
Touch “M” to enter working mode setting, the current mode flashing. Press or to switch
among Cooling , Heating & Ventilation mode , then press “M”, or wait for 15s to confirm
the choice.
Temperature setting
Touch or to set local temperature value. Hold the buttons can set continuously. Press
“M”, or wait for 15s to save and return to room temperature display.
Fan Speed setting
In normal display, press to switch among the fan speed :“ Low, Medium, High,Auto” ; Then
press “M”, or wait for 15s to confirm the choice.
Note: In Ventilation mode, no Auto speed choice.
Fan Manually control
If fan speed is manually set , the device still auto control the fan in such situation:
Cooling Mode:
Room temperature ≤ setting temperature, valve closes and fan stops;
Room temperature ≥ setting temperature +1 , valve and fan opens.℃
Heating Mode:
Room temperature ≥ setting temperature, valve closes and fan stops;
Room temperature ≤ setting temperature -1 , valve and fan opens.℃
Fan Automation
Note: Fan will operate only if the valve opens.
Cooling
Mode
Heating
Mode
a. Room temperature ≤ setting temperature,
valve closes automatically, fan stops;
b. Room temperature ≥ setting temperature
+1
, fan turned on in low speed; ℃
c. Room temperature ≥ setting temperature
+2 , fan turned on in medium speed;℃
d. Room temperature ≥ setting temperature
+3 , fan turned on in high speed;℃
a. Room temperature ≥ setting temperature,
valve closes automatically, fan stops;
b. Room temperature ≤ setting temperature
-
1 , fan turned on in low speed; ℃
c. Room temperature ≤ setting temperature
-2 , fan turned on in medium speed;℃
d. Room temperature ≤ setting temperature
-3 , fan turned on in ℃high speed;

User Manual
MCOHome Technology Co., Ltd www.mcohome.com
4
Valve Output Voltage Display
In the state of power on/off,long press to enter into valve output voltage interface, the valve output voltage
value will be displayed in the area of temperature. Output range:0~10V.
Parameter Setting
Power Failure Memory
Under the shutdown state, press& hold will enter interface for power failure memory
Selection, “PAGE” displays. Press or to change setting value, then press “M” to confirm and
return.
After power failure:
000 (default) indicates device will be in shutdown state (“OFF”) when power on again;
001 indicates device will be in working interface when power on again;
002 indicates device will stay the status before power failure when power on again.
Temp. Calibration/ Temp. Setting Range
Under the shutdown state, press & hold will enter interface for temperature calibration,
“-ERR”displays. The calibration range is among -5.0 ~ +5.0 .℃
Press or to change setting value, then press “M” save and enter interface for temp.
Range setting (0~99 ):℃
1. “-HI-” displays, the default value are 35 . Press ℃ or can set the value;
2. Press “M” again, “-LO-”displays, the default value is 5 . Press℃ or can set the value;
3. Then press “M” to confirm and return to “OFF”.
Screen Brightness/ Fan continuously work/ Key-touch volume
Under the shutdown state, press & hold “M” will enter interface for screen brightness selection
(LED), Press or can choose: (press “M” to confirm the choice and enter into next setting)
111 indicates the screen will always be full bright when power on;
000 (default) indicates without button operation for a long time (15 seconds), the screen will be
half bright automatically.
Press “M” again will enter interface for Fan continuously work choice:
000 (default) indicates device will shutdown fan and valve if room temp. Reaches setting temp.;
001 indicates device will shutdown valve only if room temp. Reaches setting temp. The fan will
continuously work in low speed.
Press “M” again will enter interface for Key-touch volume (BEEP) setting:
0: Off 1: On
Temp. Sensor Error
If temperature sensor does not work, “E1” displays , fan stops and valve closes automatically.
Z-Wave Operation
Including & Excluding of Z-Wave network
Under the shutdown state, press & hold to enter interface for inclusion or exclusion of
Z-Wave network. Before device included into network, “- - -” will display on the screen. Then
press once, device will enter learning mode to get a node ID. If inclusion is success, a node ID will
display on the screen in a few seconds.

User Manual
MCOHome Technology Co., Ltd www.mcohome.com
5
A node ID can always inform us whether the device is in the network or not.
Note: Follow the same steps to exclude the device from the network.
After inclusion, turn off the device and then turn it on. Now the device is ready to be operated by
controller/ gateway in Z-Wave network.
Association Group
Thermostat supports 1 association group. A gateway is suggested to associate with this group.
Then if any changes happen, such as: temperature, working mode, fan state etc., the thermostat will
report to this associated device (gateway). When the detected temperature changes ≥0.5 , device will ℃
send unsolicited report to the gateway.
Command Class supported by the device:
COMMAND_CLASS_BASIC;
COMMAND_CLASS_THERMOSTAT_MODE;
COMMAND_CLASS_SENSOR_MULTILEVEL;
COMMAND_CLASS_VERSION;
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE;
COMMAND_CLASS_THERMOSTAT_SETPOINT;
COMMAND_CLASS_THERMOSTAT_FAN_MODE;
COMMAND_CLASS_ASSOCIATION;
COMMAND_CLASS_MANUFACTURER_SPECIFIC;
Z-Wave Parameters Setting:
Add
Function Byte
Options Default
Remark
1 Upload temperature
format automatically
1
0x00Celsius
0x01Fahrenheit 0x02Follow
the main display
0x02
2 Upload temperature
automatically 1
0x00 OFF
0x01 Upload the difference
value only
0x02 Timing upload mode only
0x03 Upload the
difference+timing upload mode
0x03

User Manual
MCOHome Technology Co., Ltd www.mcohome.com
6
3 Upload temperature
difference 2
Base on 0.1℃unit, 0x0005 by
default, 5*0.1℃=0.5℃,
0x0003~0x03E8
0x0005
0.5℃
4 Upload time interval
regularly 2 Base on 1s unit, it suggest to be
set above 30s 0x000A~0xFFFF
0x001
E 30S
FF Factory setting 1 0x55 Restore the factory
setting(write only)
Parameters
setting back to
default value,
association
groups deleted
1-year Limited Warranty y
MCOHome warrants this product to be free from defects in material and workmanship under normal and proper use for one year from
purchase date of the original purchaser. MCOHome will, at its option, either repair or replace any part of its products that prove defective by
reason of improper workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT
THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL DISASTER, INSUFFICIENT OR
EXCESSIVE ELECTRICAL SUPPLY, ABNORMAL MECHANICAL OR ENVIRONMENTAL CONDITIONS, OR ANY
UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This limited warranty shall not apply if: (i) the product was not used in
accordance with any accompanying instructions, or (ii) the product was not used for its intended function. This limited warranty also does not
apply to any product on which the original identification information has been altered, obliterated or removed, that has not been handled or
packaged correctly, that has been sold as second-hand or that has been resold contrary to Country and other applicable export regulations.
Table of contents
Other MCOHome Thermostat manuals

MCOHome
MCOHome MH3700-HP-US User manual

MCOHome
MCOHome MH3900 User manual

MCOHome
MCOHome MCOEMH7H-WH2 User manual

MCOHome
MCOHome MH3900 User manual

MCOHome
MCOHome MH4-US User manual

MCOHome
MCOHome MH7-WH User manual

MCOHome
MCOHome MH4 User manual

MCOHome
MCOHome MCOEMH7H-EH2 User manual

MCOHome
MCOHome MH6-HP User manual

MCOHome
MCOHome MH8-FC User manual
Popular Thermostat manuals by other brands

Digital Monitoring Products
Digital Monitoring Products SecureCom Smart Z-5010T Installation and programming guide

Herz
Herz H7714 Series User and installation manual

DEVI
DEVI DEVIreg 610 installation guide

Sunvic
Sunvic TLX RFP manual

Honeywell
Honeywell CM702 user manual

Handson Technology
Handson Technology HT1209 user guide