Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
ⅡClass power unit, ungrounded
Full plastic case enclosed
Standby power consumption <0.5W
Protections: Short circuit / Over voltage / Over temperature
5 year warranty
Suitable for intelligent LED lighting
Housing with cable clamp for remote installation
Use wires with an adequate cross-section (see 5)
Use suitable mounting tools to do the wiring and mounting (see 5)
Use a (miniatureMCB circuit breaker) with an adequate current rating to protect the lighting system (see 6)
℃Maximum ambient temperature must not exceed 60
Always allow adequate ventilation clearances, 50mm, around the unit in use to prevent it from overheating
Only install the unit in interior environments
This unit must be installed by a qualified electrician
This unit is not suitable for applications that DC/DC converters are connected before LED lamps
LCM-40TW is a multiple-stage constant driver, selection of output current through DIP switch is exhibited belowpower .
Note : 1.Factory default setting is 700mA.
2.Output voltage and output wattage must not exceed the rated values.
LCM-40TW installation manual
Terminal blocks assignment for LCM-40TW
http://www.meanwell.com
Selectable current
500mA
600mA
800mA
900mA
1
ON
2
----
----
3
ONON
700mA(factory default)
---- ON ----
----ON
1050mA ----
ON
---- ---- ON
ONONON
---- ONON
--------
Status
Single-address DT6
4
----
----
----
5
ONON
ON
Dual-address DT6
Single-address DT8
(factory default)
CH1
CH1,CH2
CH1,CH2
Activatied
Channel
----
ON
----
27-50V
Voltage range
6.75
6.75
68
81.5
6.75 110
123.5
6.75 tc
: Max. Case Temperature
tc
Bottom View
40
15
2- 4.2ψ
+V
AC/L
DA+/PUSH
-V1
AC/N
39.3 65.5
7.8 7.8
4
23
2- 4ψ
TB1
LCM-40TW
+V
-V2
2
3
4
1
TB2
DA-/N
SELV
M M
110
2
EL
25-50V
20-50V
20-50V
20-44V
20-38V
180~277VAC input only
Built-in active PFC
Output current level selectable by DIP switch
Built-in DALI interface and push dimming function
Available for DALI device type 6(DT6) and device type 8(DT8)
Tunable White control
Constant po er mode output ith 2 channels
Minimum dimming level 0.2%
Emergency lighting (EL) available
MEAN WELL
2022/6/8
ISSUE