Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
‧90~132VAC input only
‧Built-in active PFC
‧Output current level selectable by DIP switch
‧Built-in DALI interface and push dimming function (DA version)
‧Built-in 0~10Vdc and PWM signal dimming function (Non-DA version)
Power supply synchronization function up to 10 units‧
‧Temperature compensation function by external NTC
‧ ⅡClass power unit, ungrounded
‧Full plastic case enclosed
‧Protections: Short circuit / Over voltage / Over temperature
‧3 year warranty
Suitable for intelligent LED lighting‧
‧Housing with cable clamp for remote installation
‧Use wires with an adequate cross-section (see 5)
‧Use suitable mounting tools to do the wiring and mounting (see 5)
‧Use a (miniature MCB circuit breaker) with an adequate current rating to protect the lighting system (see 6)
‧ ℃(LCM-60U(DA)must not exceed ℃)Maximum ambient temperature must not exceed 60 65
‧Always allow adequate ventilation clearances, 50mm, around the unit in use to prevent it from overheating
‧Only install the unit in interior environments
‧This unit must be installed by a qualified electrician
‧This unit is not suitable for applications that DC/DC converters are connected before LED lamps
The LCM can provide various output currents by setting the DIP switch. The settings of the DIP switch are shown in the tables below.
LCM-40U(DA) LCM-60U(DA)
Note : 1.Factory default setting is 700mA.
2.Output voltage and output wattage must not exceed the rated values.
Voltage
range
Voltage
range
1 12 23 34 45 56 6
Selectable
Current
Selectable
Current
2-100V 2-90V--- ------ ------ ------ ------ ------ ---
--- ------ ------ ------ ------ ---
--- ------ ---
--- ---
--- ---
--- ---
--- ---
--- ---
ON ON
ON ONON ON
ON ONON ONON ONON ON
ON ONON ONON ONON ONON ON
ON ONON ONON ONON ONON ONON ON
350mA 500mA
2-70V 2-84V500mA 600mA
2-59V 2-72V600mA 700mA*
2-50V 2-56V700mA* 900mA
2-39V 2-48V900mA 1050mA
2-34V 2-36V1050mA 1400mA
LCM-40U(DA), LCM-60U(DA) installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
-NTC
+DIM
-DIM
+NTC
-FAN
+FAN
+
DA-
DA+
PUSH
AC/N
AC/L
Terminal blocks assignment for LCM
2. Connection of LED Lamps
Press down the "push button" by a slotted screw driver to insert or remove the cable.
Vo-
Vo+
AC/N
AC/L
NEUTRAL (Blue or white)
LIVE (Brown or black)
http://www.meanwell.com
123.5mm 23mm
81.5mm
SELV
MEAN WELL
2018/1/24
ISSUE