manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Meanwell
  6. •
  7. Lighting Equipment
  8. •
  9. Meanwell LCM-40DA User manual

Meanwell LCM-40DA User manual

Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
180~295VAC input only
Built-in active PFC
Output current level selectable by DIP switch
Built-in DALI interface and push dimming function
Power supply synchronization function up to 10 units
ⅡClass power unit, ungrounded
Full plastic case enclosed
No load power consumption <0.5W
Protections: Short circuit / Over voltage / Over temperature
3 year warranty
Suitable for intelligent LED lighting
Housing with cable clamp for remote installation
Use wires with an adequate cross-section (see 5)
Use suitable mounting tools to do the wiring and mounting (see 5)
Use a (miniatureMCB circuit breaker) with an adequate current rating to protect the lighting system (see 6)
℃Maximum ambient temperature must not exceed 60
Always allow adequate ventilation clearances, 50mm, around the unit in use to prevent it from overheating
Only install the unit in interior environments
This unit must be installed by a qualified electrician
This unit is not suitable for applications that DC/DC converters are connected before LED lamps
The LCM can provide various output currents by setting the DIP switch. The settings of the DIP switch are shown in the tables below.
LCM-40DA(2) LCM-60DA(2)
Note : 1.Factory default setting is 700mA.
2.Output voltage and output wattage must not exceed the rated values.
Voltage
range
Voltage
range
112233445566
Selectable
Current
Selectable
Current
2-100V 2-90V--- ------ ------ ------ ------ ------ ---
--- ------ ------ ------ ------ ---
--- ------ ---
--- ---
--- ---
--- ---
--- ---
--- ---
ON ON
ON ONON ON
ON ONON ONON ONON ON
ON ONON ONON ONON ONON ON
ON ONON ONON ONON ONON ONON ON
350mA 500mA
2-80V 2-90V500mA 600mA
2-67V 2-86V
600mA 700mA*
2-57V 2-67V700mA* 900mA
2-45V 2-57V900mA 1050mA
2-40V 2-42V1050mA 1400mA
LCM-40DA(2), LCM-60DA(2) installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
+
DA-
DA+
PUSH
AC/N
AC/L
a. Terminal blocks assignment for LCM-40/60DA
2. Connection of LED Lamps
Press down the "push button" by a slotted screw driver to insert or remove the cable.
Vo-
Vo+
AC/N
AC/L
NEUTRAL (Blue or white)
LIVE (Brown or black)
http://www.meanwell.com
123.5mm 23mm
81.5mm
IS 15885(Part 2/Sec13)
R-41027766
THOMASSAMUEL
THOMASSAMUEL
(for DA-Type only)
2
(for DA2-Type only)
(except for DA2-Type)(except for DA2-Type)
SELV
M M
110
EL
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
-NTC
+NTC
-FAN
+FAN
+
DA-
DA+
AC/N
AC/L
b. Terminal blocks assignment for LCM-40/60DA2
123.5mm 23mm
81.5mm
-NTC
+NTC
-FAN
+FAN
3. Connection of Dimming Functions
4. NTC Connection
5. Recommended Screwdriver, Wire and Torque Setting
6. Suggested Maximum Number of the LCM Units that can be Connected to a MCB (miniature circuit breaker) at 230Vac
a. DALI (DA version only)
c. Push dim (DA version only)
d. Synchronization operation
Note: ONLY use open push button without indicator light.
Warning: Risk of short circuit. The push button can only be linked between the PUSH and the AC/L (brown or black).
DO NOT connect the push button to the AC/N (blue or white).
b. DALI2 (DA2 version only)
Note : Maximum DALI cable length is 300m
(based on a 1.5mm or 14AWG cable)
2
DA+
DA- DALI
controller
Dimming control mechanism
Function
Turn ON/OFF
Dim UP/DOWN
Reset
None
Pushing time
0.1 ~ 1 sec
1.5 ~ 10 sec
> 11 sec
< 0.05 sec
Note: These calculated values are based on MCB S201 series manufactured by ABB.
http://www.meanwell.com
Type
Model B10 B16 C10 C16
LCM-40DA(2) 15 26 27 44
LCM-60DA(2) 15 25 27 32
Solid wire
Stranded wire
American wire gauge
Wire stripping length
Screwdriver
Recommended tightening torque
Suggested push-down strength
-----
-----
-----
-----
6mm Phillips
4.6 kgf-cm (4 lb-in)
-----
The cover
(the blue one)
Push terminal
(ACL/N, PUSH, DA , Vo )
±±
ψψ1.024 - 1.628mm
0.823 - 2.08mm2
14 - 18AWG
10mm (0.39")
3mm Phillips
-----
3 - 4 kp (6.61-8.81 lb )
F
NTC-
NTC+
AC/L
AC/N
Push ButtonPUSH
LIVE (Brown or black)
NEUTRAL (Blue or white)
ψψ0.404 - 0.643mm
0.129 - 0.326mm2
22 - 26AWG
7mm (0.27")
3mm Phillips
2.88 kgf-cm (2.5 lb-in)
-----
Screw terminal
(FAN , NTC , DIM )
±±±
Every long pushing action will change the dimming direction.
Factory dimming setting: 100%
NOTE 1. Please make sure all units are set to 100% dimming setting (factory default) before synchronizing.:
2. For optional EO model: the master is EO and the salve could be standard model for economic arrangement.
3. Min. Dimming operating range depends on dimmer setting.
Synchronization up to 10 drivers (1 master + 9 slaves)
Dimming operating range : 10%~100%
Sync cable length : < 5m
Sync cable type : Flat cable
Sync cable cross section area : 22 – 24 AWG (0.2~0.3mm )
2
------
+
+
+
+
+
+
SYN. SYN. SYN.
Master Slave 1
5m 5m
DA+
DA- DALI
controller
d. Push dim (DA2 version only)
AC/L
AC/N
Push Button
LIVE (Brown or black)
NEUTRAL (Blue or white)
DA+
DA-

This manual suits for next models

3

Other Meanwell Lighting Equipment manuals

Meanwell LCM-40TW User manual

Meanwell

Meanwell LCM-40TW User manual

Meanwell LCM-25KN User manual

Meanwell

Meanwell LCM-25KN User manual

Meanwell LCM-40EO User manual

Meanwell

Meanwell LCM-40EO User manual

Meanwell GSM25E15-P1J User manual

Meanwell

Meanwell GSM25E15-P1J User manual

Meanwell LCM-40U User manual

Meanwell

Meanwell LCM-40U User manual

Popular Lighting Equipment manuals by other brands

Revolution Micro Avici V owner's manual

Revolution Micro

Revolution Micro Avici V owner's manual

Generac Power Systems MLT3080KV operating manual

Generac Power Systems

Generac Power Systems MLT3080KV operating manual

PANAVISION PANALUX SONARA 4:4 manual

PANAVISION

PANAVISION PANALUX SONARA 4:4 manual

IKEA SPÖKA manual

IKEA

IKEA SPÖKA manual

Chauvet DJ 4BAR Flex Q ILS Quick reference guide

Chauvet DJ

Chauvet DJ 4BAR Flex Q ILS Quick reference guide

Hayward Paramount MDX-R3 Owner's manual and installation guide

Hayward

Hayward Paramount MDX-R3 Owner's manual and installation guide

Lightolier Lightolier E1 Series Specifications

Lightolier

Lightolier Lightolier E1 Series Specifications

Public Safety Equipment Code 3 DuoBeam II DB2-2LMCNFPA1 Installation & operation manual

Public Safety Equipment

Public Safety Equipment Code 3 DuoBeam II DB2-2LMCNFPA1 Installation & operation manual

Crivit 339865 1910 Operation and safety notes

Crivit

Crivit 339865 1910 Operation and safety notes

TIME LED 781272 Installation and operating instructions

TIME LED

TIME LED 781272 Installation and operating instructions

PRIOS 9628209 instructions

PRIOS

PRIOS 9628209 instructions

Original BTC Cecil FT554 instruction manual

Original BTC

Original BTC Cecil FT554 instruction manual

Beninca IRI.LAMP manual

Beninca

Beninca IRI.LAMP manual

Blizzard TOURNADO RGBALC manual

Blizzard

Blizzard TOURNADO RGBALC manual

Vision & Control A-DIF-60x90-IR850-SL Instructions for use

Vision & Control

Vision & Control A-DIF-60x90-IR850-SL Instructions for use

Ikan MB4-2PT-KIT quick start guide

Ikan

Ikan MB4-2PT-KIT quick start guide

SICK deTec4 Core operating instructions

SICK

SICK deTec4 Core operating instructions

Philips Hue Runner user manual

Philips

Philips Hue Runner user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.