Control Adjustments
There are two adjustments that can be made on the 233v3 controller; BALANCE, and
RATE .
The BALANCE of positive and negative ion output can be adjusted to increase polarity
bias by simply turning the balance control towards either positive (right) or negative
(left).
When set to maximum +VE or -VE the split is 20/80 - ie at maximum positive 80% of
the ions are positive and 20% of the ions are negative (or vice versa)
The RATE POT allows the pulse frequency to be adjusted. The rate can also be set
to SSDC mode; both the positive and negative outputs are on constantly. (See scale
on product label). In pulse mode the frequency can be adjusted from 0.5 to 20 Hz.
The lower the frequency (RATE) the greater the range (ie distance over which the
ionisation will travel). A setting of 5 to 10Hz is recommended for most applications.
When set to SSDC mode the eective range of ionisation is up to 200 mm from the
ionising bar.
The purpose of these adjustments is to give total versatility to the positioning of the
ionising product attached to it.
Remember it is important to verify calibration after any adjustments and before
using your ioniser around sensitive electronics.