Operating
Manual
Pulsed DC
Controller


Products shown in this document may be covered by one or more patents, patents applied for
and/or registered designs and/or trade marks. For further information please refer to our Head
Oce or visit www.meech.com.
© Meech Static Eliminators Ltd., 26.10.2017
Contents
Introduction 3
Unpacking and Inspection 4
How to use your controller 5
Control Adjustments 7
Alarm 8
LED Displays 8
Technical Specication 9
Cleaning Instructions 10
Fault Finding 11
Repairs and Warranty 13
CE Approval 13
Health and Safety 13


3
Introduction
The Meech Model 233v3 Pulsed DC Controller has been designed to power any of the
Meech 200 series range of PDC products.

4
Unpacking And Inspection
The Model 233v3 Power Supply was carefully packed at the factory in a container
designed to protect it from accidental damage. Nevertheless, we recommend careful
examination of the carton and contents for any damage. If damage is evident, do not
destroy the carton or packing material and immediately notify the carrier of a possible
damage claim. Shipping claims must be made by the consignee to the delivering
carrier.

5
How To Use Your 233v3 Controller
1. Locate the 233v3 controller in a convenient position near to the ionising
product to be powered from it.
2. Following the polarity indicators connect the grey HV plugs of the ionising
product into the grey HV output sockets of the 233v3.
3. Connect the 24VDC input supply to the controller and switch ON. A Mains lead
for the Meech switch mode power supply is provided. The mains supply to the
switch mode must be electrically grounded.
If using anything other than the Meech 24V supply please note the zero volt (0V)
must be electrically grounded (connected to earth).
The attached ioniser will now produce Pulsed DC ionisation from its emitter pins.

6
For Best Results
1. Keep target area clear and free from obstructions to ion ow.
2. Keep work area clear of all static generative materials.
3. Only use approved static control grounding methods and material handling
equipment.

7
Control Adjustments
There are two adjustments that can be made on the 233v3 controller; BALANCE, and
RATE .
The BALANCE of positive and negative ion output can be adjusted to increase polarity
bias by simply turning the balance control towards either positive (right) or negative
(left).
When set to maximum +VE or -VE the split is 20/80 - ie at maximum positive 80% of
the ions are positive and 20% of the ions are negative (or vice versa)
The RATE POT allows the pulse frequency to be adjusted. The rate can also be set
to SSDC mode; both the positive and negative outputs are on constantly. (See scale
on product label). In pulse mode the frequency can be adjusted from 0.5 to 20 Hz.
The lower the frequency (RATE) the greater the range (ie distance over which the
ionisation will travel). A setting of 5 to 10Hz is recommended for most applications.
When set to SSDC mode the eective range of ionisation is up to 200 mm from the
ionising bar.
The purpose of these adjustments is to give total versatility to the positioning of the
ionising product attached to it.
Remember it is important to verify calibration after any adjustments and before
using your ioniser around sensitive electronics.

8
Alarm
The alarm feature detects faults in the operation of the ionising system, e.g. problems
caused by lack of product cleanliness. When a fault has been detected the alarm LED
will illuminate and the high voltage to the emitters will be automatically switched o. If
a single occurrence of a fault occurs, the controller will switch o the HV for 1 second
and then automatically reset. However, if the unit detects 5 faults in 5 seconds the HV
will be permanently switched o. The fault must be removed (e.g. by cleaning of the
ionising product) and the controller reset by switching the mains supply to it OFF and
ON.
An 8 way DIN socket is provided to mirror the alarm function to a central control panel
(see specication for connection detail).
LED Displays
The 233v3 has four indicator lights
1. Power light (Red) - Illuminated when 24VDC supply
is provided to the unit.
2. Alarm light (Orange) - Illuminated when unit has detected a fault and
has shut down.
3. Positive balance light ( red) - indicates positive voltage and pulse rate
4. Negative balance light ( green) - indicates negative voltage and pulse rate

9
Technical Specication
Model 233v3 Power supply
Input voltage : 24V D.C (+/- 5% 0.25A max- source must have earth return)
Input connector : 2.5mm jack - centre positive
Output voltage : Adjustable between 4kV D.C. and 8kV D.C.
Output current : 120 Micro amps.
Output balance : Adjustable between a ratio of positive and negative of 20/80
to 80/20.
Output frequency : Adjustable between 0.5Hz and 20Hz or can be set to
SSDC mode
Weight : 0.3kg
Remote On / O : 3.5mm Jack
Alarm relay : 8 pin DIN connector
Pin 1 Relay normally closed contact
Pin 2 Ground
Pin 3 +24V
Pin 4 Relay normally open contact
Pin 5 Not used
Pin 6 Relay common contact
Pin 7 Feedback signal
Pin 8 Not used
Note: RL1 is only rated for 24V dc 5 amp
Operating temp. :-10 Deg C to +65 Deg C
Short circuit
Back up protection: Controller must be supplied from a switched outlet incorporating a
1 amp fuse.

Cleaning Instructions
Your Meech Pulsed DC Controller was designed to be virtually maintenance free.
1. Be sure the unit is switched o and disconnected from the mains supply.
2. The outside case may be wiped down with a soft damp cloth.
3. Let dry for a minute and turn back on.
10

Fault Finding
Tests must be completed by a qualied electrical engineer.
If in doubt contact Meech head oce or your local distributor.
CAUTION: Whilst no danger to personnel exists, it is essential than any high
voltage ionising equipment, makes no contact with water or water based uids.
Should such an event occur, disconnect immediately and return equipment to the
manufacturer for water damage assessment. High voltage electrical equipment should
not make contact with water.
The Model 233v3 Power Supply and attached ionising products form part of a system.
To verify where a fault may have occurred it is important to test each item of the
system individually. Should more than one ionising appliance be connected to the
power supply, these must be tested individually.
To check the Pulsed DC system, follow the procedure detailed below:
1. Switch o the electrical supply to the system.
11

2. Disconnect all ionising appliances from the controller.
3. Reconnect the supply and switch ON the unit.
4. Using a high voltage probe ( 1000:1 ) and meter measure the voltage on
each of the output sockets. The reading should be at Max. power 8 kV
5. If the controller is found to be functional, test each of the attached products
independently following the instructions detailed in the appropriate Operation
and Maintenance manual.
If the 233v3 controller is found to be faulty please contact your local distributor or
Meech Static Eliminators Ltd. ( Tel. +44(0)1993 706700).
12

Repair and Warranty
The Meech Model 233v3 Pulsed DC Controller is warranted by Meech Static
Eliminators Ltd to the original purchaser against defects in material and workmanship
for one year after purchase. Should any malfunction occur, please return the Ioniser
directly to us. All products returned to the factory MUST be accompanied by a return
authorisation number and must be shipped prepaid. For prompt service, ship the unit to
the factory with the return authorisation number shown clearly on the label. Be sure it is
well packed in a sturdy carton with shock absorbing material.
Include a note stating the nature of the problem as specically as possible, and also
include instructions for returning the Ioniser to you. We will pay one-way return surface
shipping costs on any repairs covered under the warranty.
Field repairs should not be undertaken during the warranty period. Repair attempts by
unqualied personnel will invalidate the warranty.
CE Approval
An EC Declaration of Conformity for this product exists in respect of the Low Voltage
Directive:72/23/EEC (“LVD”) & Electromagnetic Compatibility Directive: 89/336/EEC
(“EMCD”)
Health and Safety
Emission of Ozone: Considerably below international standard of 0.1ppm.
13

©Meech Stac Eliminators Ltd 2017 www.meech.com
Meech Internaonal
2 Network Point
Range Road, Witney
OX29 0YN, UK
Tel: +44 (0)1993 706700
Fax: +44 (0)1993 776977
email: [email protected]
Meech Stac Eliminators
(Shanghai) Co. Ltd
7G, 7F, LP Tower
#25 Xiangfeng Road
201103 Shanghai
China
Tel: +86 400 820 0102
Fax: +86 21 6405 7736
email: [email protected]
Meech Stac Eliminators USA Inc
2915 Newpark Drive
Norton, OH 44203
USA
Tel: +1 330 564 2000 / 1 800 232 4210
Fax: +1 330 564 2005
email: [email protected]
Meech Shavotech
29/2, Kharadi
O Pune-Nagar Road
On Old Kharadi Mundhwa Road
Pune : 411014 , Maharashtra
India
Tel: +91 (0)703 093 8211 / +91 (0)741 000 4817
Fax: +91 (080) 28395963
email: [email protected]
Meech Elektrostak SA
Kaiserbaracke 166
B-4780 St.Vith
Belgium
Tel.: +49 (0)6555 3733 399
+32 (0)80 670 204
Fax: +32 (0)80 862 821
email: [email protected]
Meech Internaonal
(Singapore) Pte. Ltd.
7 Temasek Boulevard
12 - 07 Suntec Tower One
Singapore
Singapore
038987
Tel: +65 65918859
email: [email protected]
Meech CE
Gábor László utca 2
Budapest 1041
Hungary
Tel: +36 1 7977039
+36 30 2803334
email: [email protected]
Other manuals for 233v3
1
Table of contents
Other Meech Controllers manuals