Meech HYPERION 233v4 User manual

1
Opera ng Manual
Hyperion 233v4
Pulsed DC Controller

2
Products shown in this document may be covered by one or more patents, patents applied for and/or reg-
istered designs and/or trade marks. For further informaon please refer to our Head Oce or visit www.
meech.com.
Document version: 2 Soware version: 3.02.05
© Meech Stac Eliminators Ltd., 04.01.2022
Contents
Introducon................................................................................................... 3
Package Contents ......................................................................................... 4
Features and Benets of the 233v4 Pulsed DC Controller............................. 5
Installaon .................................................................................................... 8
Dual Alarm Alert ......................................................................................... 12
Output Drive ............................................................................................... 14
Operaon ................................................................................................... 17
BarMaster ................................................................................................... 21
Adjustments ................................................................................................ 22
Maintenance ............................................................................................... 24
Fault Finding ................................................................................................ 25
Technical Construcon ................................................................................ 29
Repairs And Warranty ................................................................................. 30
CE Approval ................................................................................................. 30
Health and Safety ........................................................................................ 30
Technical Drawing........................................................................................ 31

3
Introducon
The Hyperion 233v4 Pulsed DC Controller is a compact and powerful 15kV
controller. It was principally designed to directly power two Meech pulsed DC
ionisers. If more ionisers are required, they can be connected via spliers.
The versality and exibility of the 233v4 make it suitable to use in a wide
range of industries. Installaon and set up of the controller are easily
achieved.
The 233v4 features all the adjustability and monitoring that you would
expect from a Hyperion product. Fully BarMaster and SmartControl Touch
compable, the output voltage, frequency and balance can all be adjusted
to suit parcularly dicult applicaons. The adjustable output voltage
is parcularly useful in very sensive applicaons such as those found in
cleanroom environments.
The Hyperion BarMaster remote programmer and SmartControl Touch are
available for purchase from the Meech network: Visit www.meech.com to
nd your nearest Meech oce or distributor for further product informaon.

4
Unpacking and Inspecon
The Model 233v4 has been carefully packed at the factory in a container
designed to protect it from accidental damage. Nevertheless, we recommend
careful examinaon of the carton and contents for any damage.
If damage is evident, do not destroy the carton or packing material and
immediately nofy the carrier of a possible damage claim. Shipping claims
must be made by the consignee to the delivering carrier.
Package Contents
Standard:
233v4 Controller
Oponal:
Power Cable - 4 Pin M8
(straight or 90° elbow)
Available in 2,3,5 and
10M lengths.
C5 cable and 24V DC
Supply
BarMaster remote
programmer:
Allows opmisaon of
the output of the 233v4
Oponal:
SmartControl Touch:
Allows opmisaon of the
output of the 233v4 and moni-
toring and data logging plus
remote access.

5
Features and Benets of the 233v4 Pulsed DC
Controller
Overall look
The Hyperion 233v4 is a compact pulsed DC controller. It is constructed of
DuraForm PA (Nylon 12) with dimensions of 46 x 93 x 129mm.
High Voltage Output
The 233v4 has an adjustable output voltage from 2kV to 15kV. The 233v4
will be congured to suit the type of installaon and the type of ionising
equipment connected to it.
Low Voltage Wiring
The 233v4 is powered by 24V DC via a 4-pin M8 Connector, used throughout
the Hyperion range. This greatly simplies installaon; avoiding the need to
route high voltage cables from a remote high voltage power supply.

6
Clean Pin Alert LED
The 233v4 has 6 modes. The local LED illuminates either red, green or amber
to indicate it’s current operaon.
Below are the 6 modes for the LED status:
Green Connuous - HT on
Green Flashing - HT on, BarMaster connected
Amber Connuous - Standby mode (remote control)
Amber Flashing - Standby mode (remote control), BarMaster
connected
Red Connuous - HT failure alarm
Red Flashing - Clean pin alarm
Clean Pin Alert and Fault Output
An output signal indicates when the ionisers needs cleaning or when a fault
has been detected. The signal is 0V/24V output on pin 2.
By default: Bar OK = 24V
Bar needs cleaning (or fault detected) = 0V
If required the signal can be inverted to give OK = 0V, Cleaning Required = 24V
using a Barmaster Remote Programmer.

7
Remote Signal
In the case of the Clean Pin Alert signal, the Cleaning Alert LED will acvate.
This can be monitored remotely to alert the operator to aend to the
controller.
Sealed Construcon
IP67 construcon allows the controller to be mounted in areas subject to
wash-down or spillage.
WARNING
This equipment must be grounded /earthed via the mains cable. Failure
to do so can result in damage to the unit.

8
Installaon
Installaon and connecon should be completed by a qualied electrical
engineer.
Install the 233v4 in a dry, well venlated area. Allow sucient space for the
cables on the right hand side of the unit.
Mount the unit using the holes provided.
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Liam Fernley
09/01/2018
Drawn by:Date:
2 / 2
Scale
Sheet
Meech International
2 Network Point
Range Road, Witney
OX29 0YN, UK
Tel: +44 (0) 1993 706700
Fax: +44 (0) 1993 776977
email: sales@meech.com
web: www.meech.com
COPYRIGHT © MEECH STATIC ELIMINATORS
THIS DOCUMENT AND THE INFORMATION THERE IN IS THE PROPERTY OF THE MEECH GROUP AND SHOULD NOT BE COPIED IN WHOLE OR PART OR USED FOR MANUFACTURE OR OTHERWISE DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF M EECH INTERNATIONAL
MATERIAL:
FINISH:
TOLERANCE UNLESS
OTHERWISE SPECIFIED
Machined Work Metric ±0.1mm
Unmachined Fabrications ±1mm
Angular ±0°30'
PROJECTION
DIMENSIONS IN MM
DO NOT SCALE
TITLE:
DRAWING No:
REVISION:
SHEET:
A3
STATUS:
CRITICAL TO FUNCTION
(CTF) DIMENSION S AS
MARKED
SIGNED OFF:
'Meech Internati onal' is a trading style of
Meech Static Elim inators Ltd
11,4101,6
75,0 8,5
53,6
3-off Mounting holes to suit M5 cap head screw
233V4 Mounting Positions
Connect ionising equipment using grey HT connecons

9
Connect the 24V DC supply with 4 Pin M8 cable to the controller.
Electrical Installaon
WARNING
The 233v4 requires a grounded 24V DC supply. The 0V line must be
connected to ground. Failure to do so, will result in damage to the ioniser or
the 24V supply and will void the warranty.
A grounding post on the controller is provided for this purpose. Meech
recommend that, for certainty, the controller is grounded using this post, in
addion to using a grounded 24V DC supply.

10
Connecon to the 233v4 is via an M8 4 Pin connector. With the following pin-
outs:
2 4
1 3
Male connector on Controller
4 2
3 1
Female connector on Cable
Pin Colour Funcon Specicaon
1Brown Input 24V
2 White Output Clean pin 0V/24V
3Blue Input 0V/ Ground
4Black Output HT Failure 0V/24V
For the rst 60 seconds of start-up, the unit is in communicaons mode and
will output 24V on both alarm lines.
Aer 60 seconds, both alarm lines revert to being used for alarm purposes.

11
Connecon using Meech 24V DC power supply
Meech 24V DC supplies are grounded internally. It is important that the mains
connecon oers a ground connecon. Two-pin outlets without a ground
connecon must not be used, unless the ground post on the 233v4 controller
is connected to ground.
The Meech switchmode power supply has a C5 socket and a 2000mm cable to
an M8 Connector. A break-out wire from the power supply provides the Clean
Pin Alert output signal.
Note: The 233v4 does not come with a 24V DC power supply and must be
ordered seprately.
Connecon using customer’s own power supply:
It is the customer’s responsibility to check that the 24V power supply they will
be using is grounded. If it is NOT grounded they must check that grounding it
via the ground post on the 233v4 controller will not aect any other systems
running from that power source.
The 24V supply should be protected with a 1 Amp fuse.

12
Dual Alarm Alert - Remote Monitoring
Remote monitoring of the need to clean the bar is provided by the output signal on
pin 2 (white) and fault alert is provided on pin 4 (black). The signal is 0V-24V suitable
for direct connection to a PLC input. The output impedance of the signal is 10kΩ. The
output can also be congured to power an external relay to provide volt-free contacts
for other monitoring systems.
Using a BarMaster remote programmer or SmartControl the output can be set
to Alarm True = Lo (Normally Open) which is factory default or Alarm True = Hi
(Normally Closed).
NOTE: Make sure that BarMaster is not connected when using the dual alarm
remote monitoring feature.
Alarm Pins
Pin-2 (White) This pin is used to report when the HV output of the equipment
needs cleaning. This is considered as a warning signal. The LED
pattern on the unit is ashing red.
Pin-4 (Black) This pin is used to report when the HV output of the equipment is
critically low. This is considered as a serious fault. The LED pattern
on the unit is solid red.

13
Alarm Logic Level
This is given by the conguration of the “Alarm True” setting using the BarMaster.
Alarm True = hi
This means the logic on both the alarm pins is active high.
Alarm True = lo
This means the logic on both the alarm pins is active low.

14
Output Drive
There are 3 dierent output drive options which are designed to fulll the vast majority
of user requirements and to allow easy integration to PLC equipment.
Option 1 - NPN
Transistor-driven switch which presents a pull-up resistor to 24VDC on the alarm pin.
This conguration is the same for both alarm pins (pin-2 and pin-4).
Simplied Diagram of NPN output
Logic Table
Alarm True = Hi
Start State Solid Green Flashing Red Solid Red
White Hi Lo Hi Hi
Black Hi Lo Lo Hi
Alarm True = Lo
Start State Solid Green Flashing Red Solid Red
White Hi Hi Lo Lo
Black Hi Hi Hi Lo
Note: On unit power-up, both alarm pins remain in Hi state for up to 60 seconds
before these are used as alarm pins.
2.2kΩ

15
Option 2 - PNP
Transistor-driven switch which presents a pull-down resistor to GND on the alarm pin.
This conguration is the same for both alarm pins (pin-2 and pin-4).
Simplied Diagram of PNP output
Logic Table
Alarm True = Hi
Start State Solid Green Flashing Red Solid Red
White Hi Lo Hi Hi
Black Hi Lo Lo Hi
Alarm True = Lo
Start State Solid Green Flashing Red Solid Red
White Hi Hi Lo Lo
Black Hi Hi Hi Lo
Note: On unit power-up, both alarm pins remain in Hi state for up to 60 seconds
before these are used as alarm pins.
2.2kΩ

16
Option 3 - N+P
This option presents the combination of both of the previous cases, NPN and PNP,
however, the alarm lines are hard-driven to either 24VDC or GND.This conguration is
the same for both alarm pins (pin-2 and pin-4).
Simplied Diagram of N+P output
Logic Table
Alarm True = Hi
Start State Solid Green Flashing Red Solid Red
White Hi Lo Hi Hi
Black Hi Lo Lo Hi
Alarm True = Lo
Start State Solid Green Flashing Red Solid Red
White Hi Hi Lo Lo
Black Hi Hi Hi Lo
Note: On unit power-up, both alarm pins remain in Hi state for up to 60 seconds
before these are used as alarm pins.
Note: When ‘a’ is closed, ‘b’ is
open and vice versa.

17
Operaon
Geng Started
The 233v4 must be congured to suit the installaon and the ionising
equipment connected to it. Before you receive your 233v4, Meech, if
required, will preset the controller to suit your applicaon. This includes
applying basic sengs of the output power, rate and balance as well as alarm
funconality and the lock opon.
Note: If you are using it with a 971 ionising bar it will be preset to 15KV.
To change these sengs you will need a BarMaster or SmartControl Touch
and to follow the instrucons below.
Seng the Start Voltage and Ion Output Set Point
During installaon and commissioning, two parameters must be set correctly
to allow opmum performance:
1. Voltage Output. The correct start voltage must be set, depending on the
ioniser connected to the 233v4. The correct output voltages for Meech
ionisers are:
971 15 kV
242 10 kV
251 9 kV
261v2 9 kV
271/272/273 9 kV
976 Head 9 kV
976 Mini 9kV
2. Ion Output Set Point: This is the target Ion Output as measured when the
system is clean.

18
This value should only be set when the ionisers have been cleaned,
otherwise the performance of the system will be reduced.
During use, ionisers become contaminated which reduces their performance.
Seng the Rate
The 233v4 features a variable output frequency. The frequency that the
233v4 should be set to depends on the ionising product and the distance to
the target object.
Frequency Rate (Hz)
Suggested Frequency Vs Operang Distance for 971/233v4
Ionising Nozzles:
Ionising Nozzles and Air Guns (251,261,271) should be used from 10 to 20 Hz.

19
Seng the Balance
The output of the 233v4 can be biased to negave or posive. The
adjustment changes the percentage of me that each HT output is switched
on. The maximum bias is 80% to either posive or negave.
50% posive 80% negave
Changing the balance of the output changes the relave amount of posive
and negave ions produced by the ioniser. With the help of a stac locator
the balance can be adjusted for more accurate neutralisaon of the target
material.
To set the balance see BarMaster secon (page 19).
Seng the Alarm Point
The 233v4 features an adjustable alarm that will alert the operator when the
Ion Output of the ionising system falls below a desired level or when a system
fault is detected.
To alert the operator to the need for cleaning, the 233v4 will trigger the LED
to ash red.
The alarm point is set as a percentage of maximum Ion Output. An inial
value of 35% is recommended.
To set the Alarm Point see BarMaster secon (page 21) or the SmartControl
Touch manual.

20
Input/Output Connecons
Remote On/O
The output of the 233v4 can be turned on and o remotely via the 3 pin
female socket located on the connecon panel.
A 3 pin M8 connecon to volt-free contacts will allow the 233v4 to be
switched on when the contacts are made.
Pin Colour Specicaon
1Blue On/O Remote Control
2 Black Not Used
3Brown O/V ground
Table of contents