MELER GLUING SOLUTIONS
2-2
INTRODUCTION
Modes of operation
The hot-melt melters/applicators may be used in all of the following modes:
• READY Mode (Prepared). The melter keeps the components hot at the
programmed working temperature. The pump is kept idle, awaiting an
adhesive pump request.
• RUNNING Mode (in Operation). The unit pumps adhesive, and all
programmed working conditions are correct.
Internal control of pumping and speed _ In this mode of
operation, the user has full control of pumping and the set speed
of the pump rotation.
Control of internal pumping and external speed_ This mode of
operation is performed through internal pumping control and
speed control by means of an external 0-10 V signal sent from the
main machine.
Control of external pumping and internal speed_ This mode of
operation is performed through external pumping control and
manual speed control.
Control of external pumping and speed_ In this working mode,
both pumping and speed are controlled from the main machine.
Speed is controlled by means of an external 0-10 V signal sent
from the main machine.
• STOPPED Mode (Pumping disabled). The pump is kept disabled until the
pump is either manually or automatically activated.
• Heating Mode. The unit heats the areas up to the programmed
temperature. The pump is kept disabled.
• STANDBY Mode (Low consumption). The melter remains in standby while
maintaining all active areas at a programmable temperature. The pump
remains disabled.
• WARNING Mode. The melter detects an incorrect operation or warns the
operator about the event. The unit can continue to operate.
• ALARM Mode. The melter detects an operation error or warns the
operator about the event. Depending on the type of alarm, the unit may
continue to operate for a programmed amount of time.
• ERROR Mode. The melter detects an operation error or warns the
operator about the event. The unit cannot continue to operate, and
pumping is stopped immediately. Depending on the type of error, the unit
disconnects heating from all the areas.
• OFF Mode. The unit remains off with no areas heated and the pump
disabled. The power and pneumatic supply from the network to the unit is
maintained.
Hot-melt melter/applicator identification
When placing orders for replacement parts or requesting help from our
service center, you should know the model and reference number of your hot-
melt melter/applicator.
This and other technical information will be found on the identification plate
located on the side of the lower part of the hot-melt melter.
75 rpm
50 rpm
50 rpm
49 rpm
53 rpm
POMPA 1
Velocità reale:
Riferimento esterno 1
Permesso esterno 1
Switch 1
Velocità reale:
Riferimento esterno 2
Permesso esterno 2
Switch 2
POMPA 2