4
YourNaturalGasGrillisdesignedtooperateon
NaturalGasonly,atapressureof7"watercolumn
(W.C.)(1/4psior1.75kpa),regulated atthe
residentialmeter.Check withyourgasutility
companyforlocal gaspressureandwithyourlocal
municipalityforbuildingcoderequirements.Ifyour
residential gaslinepressurehasnotbeen
regulatedto7"W.C., contact yourlocalgas
utilitycompanyforprofessionalassistance.
ThegaspressureRegulatorsuppliedwiththis
appliancemustbeused.ThisRegulatoris
setforanoutletpressureof4"W.C.
It isrecommendedthataShutOff Valvebeinstalled
at thegassupplysourceoutdoors.Install atapoint
afterthe gaspipeexitstheoutsidewalland beforethe
QuickDisconnectHose, orinstall itat the point
beforethegaslinepiping enterstheground.See
Figure1.
Pipesealingcompoundorpipethreadtaperesistant
tothe actionofNaturalGasmustbeusedonallmale
pipe threadswhenmakingtheconnection.
Disconnectyourgasgrillfromfuelsourcewhen
the gassupplyisbeing tested athigh pressures.
Thisgasgrillanditsindividual ShutOffValvemust
be disconnected fromthegassupplypipesystem
during anypressuretesting ofthatsystemat
pressurein excess of1/2psi(3.5kpa).
Turnoff yourgasgrillwhen thegassupplyis
tested atlowpressures.The grill mustbe isolated
fromthe gassupplypipesystembyclosingits
individual Manual ShutOffValveduringany
pressuretesting ofthe gassupplypipe systemat
pressuresequaltoorless than 1/2psi(3.5kpa).
The Quick Disconnectconnectstoa3/8inchNPT
threadfromgassource.TheQuick Disconnect
fitting isahand operateddevicethatautomatically
shutsoff the theflowofgasfromthe sourcewhen
itisdisconnected.
The QuickDisconnectfitting can be installed
horizontally,orpointingdownward.DONOT install
thefitting withtheopening pointing upward
becausethe fitting couldcollectwateranddebris.
TheDustCovers(plasticplugs)providedwiththe
Quick Disconnecthelpkeep the open ends
clean whiledisconnected.
The outdoorconnectormustbe firmlyattached to
aridged permanentconstruction.
TheQuickDisconnectMUSTBEinstalled above
ground.
WARNING: Donotroutethe 12 footQuick
DisconnectHoseunderadeck.The hosemustbe
visibleand inspected priortoeachgrilluse.
Figure 1
(ForNaturalGas ModelOnly)
If the lengthoflinerequireddoesnotexceed50feet,
usea5/8"O.D.tube. One sizelargershouldbe used
forlengthsgreaterthan50feet.
Gaspipingmaybe coppertubing,type KorL;
polyethylene plastictube,withaminimumwall
thickness of.062inch;orstandardweight(schedule
40)steelorwroughtiron pipe.
Coppertubingmustbetin-linedifthegascontains
morethan0.3gramsofhydrogen sulfideper100
cubicfeetofgas.
Plastictubingissuitableonlyforoutdoor,under-
grounduse.
Gaspipingincontactwithearth,oranyothermate-
rialwhichmaycorrode thepiping,mustbe protected
againstcorrosioninanapprovedmanner.
Undergroundpiping musthaveaminimumof18"
cover.
Allconnectionsand jointsmustbe thoroughlytested
forleaksinaccordancewithlocal codesandalllisted
proceduresinthe latesteditionofANSIZ223.1
Gas LinePiping
TestConnections
NATURAL GASSUPPLY
QUICK
DISCONNECT
INSIDEWALL
OUTSIDEWALL
MALE
FITTING
TONATURAL GAS
REGULATOR
LOCKINGGAS
SHUTOFF VALVE LOCKING
GAS
SHUTOFF
VALVE
Additional
HardwareNot
Included
NaturalGasSafetyInstructions
Donotuseanopenflame tocheck for
gas leaks.Be sure there are no sparks
oropenflamesin theareawhileyou
check forgas leaks.Thiswill resultin a
fire orexplosionwhichcancauseserious
bodilyinjury ordeath, anddamageto
property.
DANGER