If a remote control is lost, stolen or damaged, it is possible to disarm the alarm system with a 5
digit emergency code.
Perform the following procedure.
Switched the ignition ON then OFF; the LED will turn ON, turn OFF and then start to fl ash after 2
seconds.
8. ‘OVERRIDE’ EMERGENCY CODE
DISARM
OK
x1 x3 x2 x1 x2
ALARM
IN ACTIVE
PHASE
(AFTER 26 SEC.)
“OVERRIDE”
EMERGENCY CODE
2 SEC.
3 QUICK
FLASHES
CONFIRM
3 QUICK
FLASHES
CONFIRM
3 QUICK
FLASHES
CONFIRM
( WITHIN 2 SEC. )
WITHIN 10 SEC. WITHIN 10 SEC. WITHIN 10 SEC. WITHIN 10 SEC.
Power supply .......................................................................................................12Vcc (10V-15V)
Consumption .........................................................................................................................1,0 mA
Consumption in DEEP SLEEP MODE ............................................................................. 0,3 mA
Operating temperature ..........................................................................................- 25°C + 85°C
Sound level of siren ..............................................................................................................114 dB
Self-supply autonomy ...................................................................................................5 minutes
Remote controls ...................................72 million billion variable codes (lithium battery)
Sensitivity of internal movement sensor .....................................................1,5° per second
Frequency of Mycro remote control .....................................................................433.92 MHz
9. SPECIFICATIONS
Initial immunity phase ...............................................................................................26 seconds
Duration of alarm cycle ...............................................................................................26 seconds
Interval between alarm cycles/No .......................................................................5 seconds/10
Passive arming delay ...................................................................................................50 seconds
DEEP SLEEP MODE delay ..............................................................................................5 days
Frequency of direction indicators .......................................................0,4 sec.Off /0,4 sec.On
10.TIMINGS