Table of contents ■■■■■■■■■■■■■■■■■■■■■■
IV ■■■■■■■■ 940 Professional IC Vario ONE/ChS (2.940.1200)
3.13.2 Connecting the Metrohm Suppressor Module (MSM) ............. 34
3.14 Installing the conductivity detector .................................. 38
3.15 Installing the amperometric detector ............................... 39
3.16 Connecting the sample degasser (optional) ..................... 40
3.17 Connecting the instrument to a computer ....................... 41
3.18 Connecting the instrument to the power grid ................. 42
3.19 Initial start-up ..................................................................... 43
3.20 Connecting and rinsing the guard column ....................... 45
3.21 Connecting the separation column ................................... 47
3.22 Conditioning ........................................................................ 51
4 Operation 53
5 Operation and maintenance 54
5.1 IC system ............................................................................. 54
5.1.1 Operation .............................................................................. 54
5.1.2 Care ...................................................................................... 54
5.1.3 Maintenance by Metrohm Service .......................................... 54
5.1.4 Shutting down and recommissioning ..................................... 55
5.2 Capillary connections ......................................................... 56
5.3 Servicing the door .............................................................. 56
5.4 Column thermostat – Replacing the capillaries ............... 56
5.5 Handling the eluent ............................................................ 58
5.5.1 Manufacturing eluent ............................................................ 58
5.5.2 Changing the eluent .............................................................. 59
5.6 Servicing the eluent degasser ........................................... 59
5.7 Notes on operating the high-pressure pump ................... 60
5.8 Servicing the high-pressure pump .................................... 61
5.9 Servicing the inline filter .................................................... 74
5.10 Servicing the pulsation absorber ...................................... 77
5.11 Injection valve ..................................................................... 77
5.12 Metrohm Suppressor Module (MSM) ............................... 77
5.12.1 Notes for operating the Metrohm Suppressor Module
(MSM) ................................................................................... 77
5.12.2 Taking care of the suppressor housing ................................... 78
5.12.3 Servicing the Metrohm Suppressor Module (MSM) ................. 78
5.13 Servicing the detector ........................................................ 86
5.14 Rinsing the sample path .................................................... 86