BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• Functional insulation is maintained between the input
and output.
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel
configurations, connected devices, connected wires, may
affect the protection level of this unit when it is inte-
grated in a panel system. The user may have to review
the CE requirements in regard to the whole system and
employ additional protective measures* to ensure the
CE conformity.
* For example, installation of noise filters and clamp fil-
ters for the power source, input and output connected
to the unit, etc.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 30mA
(50mA for current output)
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 95% RH in
order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications
Span Adj.
Zero Adj.
Mounting Screw
Body
INSTALLATION
Use Installation Base (model: M8BSx).
MILLIVOLT CONVERTER
(CE) MODEL M8VS1
EM-5382 Rev.2 P. 1 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
I/O PINS
17.5 (.69)
48 (1.89)
75 (2.95)
83 (3.27)
■CONNECTION DIAGRAM
+
–
Installation Base
OUTPUT 1
6
7
8
9
10
11
+
–
+
–
OUTPUT 2
1
2
A
B
POWER
+
–
INPUT
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input: Check the power input voltage.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
(Output 1 and Output 2 are linked.)
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.
M8VS1
EM-5382 Rev.2 P. 2 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Other MG Media Converter manuals

MG 18CE User manual

MG

MG 18CE User manual

MG WRPPB User manual

MG

MG WRPPB User manual

MG STE02W User manual

MG

MG STE02W User manual

MG 18RS User manual

MG

MG 18RS User manual

MG M80YV User manual

MG

MG M80YV User manual

MG 17VS User manual

MG

MG 17VS User manual

MG KAPU User manual

MG

MG KAPU User manual

MG 17RS User manual

MG

MG 17RS User manual

MG KAP User manual

MG

MG KAP User manual

Popular Media Converter manuals by other brands

Mylaps X2 Club manual

Mylaps

Mylaps X2 Club manual

CYP CH-521RXHS Operation manual

CYP

CYP CH-521RXHS Operation manual

ZeeVee ZvBox 170 Configuration manual

ZeeVee

ZeeVee ZvBox 170 Configuration manual

RLH Industries 2 Channel 4 Wire Datawith E&M and I/O user guide

RLH Industries

RLH Industries 2 Channel 4 Wire Datawith E&M and I/O user guide

StarTech.com ET10GSFP manual

StarTech.com

StarTech.com ET10GSFP manual

Terahertz Technologies TIA-2000 operating instructions

Terahertz Technologies

Terahertz Technologies TIA-2000 operating instructions

Comtech EF Data MBT-5000A Installation and operation manual

Comtech EF Data

Comtech EF Data MBT-5000A Installation and operation manual

SRS Light Design DST8-DIN Series instruction manual

SRS Light Design

SRS Light Design DST8-DIN Series instruction manual

Kramer VP-439 user manual

Kramer

Kramer VP-439 user manual

RME Audio Micstasy specification

RME Audio

RME Audio Micstasy specification

Lika LINEPULS SME53 Series Mounting instructions

Lika

Lika LINEPULS SME53 Series Mounting instructions

eks e-light EL100-S Series manual

eks

eks e-light EL100-S Series manual

LEGRAND 4 306 26 user manual

LEGRAND

LEGRAND 4 306 26 user manual

Lika ROTACOD AMR58 Series manual

Lika

Lika ROTACOD AMR58 Series manual

Prolon PL-485-BT user manual

Prolon

Prolon PL-485-BT user manual

VXI SVM2608 user manual

VXI

VXI SVM2608 user manual

Elko eLAN-IR-003 installation manual

Elko

Elko eLAN-IR-003 installation manual

Baumer OG 90 Mounting and operating instructions

Baumer

Baumer OG 90 Mounting and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.