MHM Synchroprint X-Type plus User manual

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 1 of 45
OPERATING INSTRUCTIONS
(Translation of the original instructions)
MHM SCREEN PRINTING MACHINE
SYNCHROPRINT X-Type plus
©2012-2016 Machines Highest Mechatronic GmbH, Erl, Austria

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 2 of 45
Preface
Dear Customer,
congratulations and thank you for choosing the MHM Synchroprint X-Type plus Screen Printing
Machine. This machine is designed to provide the highest standards of performance and reliability
during its guaranteed long operating life. Highly innovative and precise MHM technology provides
a combination of the finest built quality along with optimal safety. We trust that these Operating
Instructions will assist you in becoming familiar with the safe and efficient operation of the
Synchroprint X-Type plus.
Important Note:
Due to our policy of continuous improvement, we reserve the right to change specifications without
prior notice. Therefore, certain individual fittings and components may differ slightly from the
model detailed in this document. For any further questions regarding your Synchroprint X-Type
plus, please contact the MHM service team.
Wishing you every success with your future production.
Machines Highest Mechatronic GmbH
Important Advice Regarding These Operating Instructions
These Operating Instructions form an integral part of the Synchroprint X-Type plus and must be
made available to all authorized personnel at all times. No particular sections or pages must be
removed from these Operating Instructions, and any missing sections or pages should be replaced
immediately, in particular with regard to section “1. Safety Instructions”.
These Operating Instructions are subject to international copyright and may not be reproduced
and/or revised without our prior written approval.
©2012-2016 Machines Highest Mechatronic GmbH, Erl, Austria. (All rights reserved).
Published by: Machines Highest Mechatronic GmbH
Muehlgraben 43a
A-6343 Erl / AUSTRIA
Contact details: Telephone:+43 (0) 5373 –76080-18
Fax: +43 (0) 5373 –76080-20
Mobile: +43 (0) 664 –8151380
Erl, February 2016

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 3 of 45
Content:
Preface..................................................................................................................................................2
Important Advice Regarding These Operating Instructions ................................................................2
1. Safety Instructions........................................................................................................................5
1.1. Description of Key Words and Symbols in the Operating Instructions................................5
1.2. General Information..............................................................................................................6
1.3. Qualification of Operating and Service Staff........................................................................6
1.4. Required qualification for operations....................................................................................7
1.5. Safety Instructions for the Operating Staff............................................................................8
1.6. Personal Protective Equipment .............................................................................................8
1.7. Additional Risks....................................................................................................................9
1.8. Safety Signs on the Machine...............................................................................................10
1.9. Other Valid Rules and Regulations:....................................................................................10
2. Intended usage of the machine...................................................................................................10
3. Data............................................................................................................................................10
3.1. Serial Number and Year of Manufacture............................................................................10
3.2. Dimensions..........................................................................................................................11
3.3. Specifications ......................................................................................................................11
4. Transportation and packaging....................................................................................................12
4.1. General Notes with Regard to Transportation and Danger Warnings.................................12
4.2. Packaging ............................................................................................................................12
4.3. Unloading of the crates........................................................................................................12
4.4. Packaging material ..............................................................................................................12
5. Assembly....................................................................................................................................13
5.1. General Assembly Instructions ...........................................................................................13
5.2. Positioning of the Synchroprint...........................................................................................13
5.3. Ambient Conditions ............................................................................................................13
5.4. External supply/Connection ports.......................................................................................14
5.4.1. Electrical Connections .................................................................................................14
5.4.2. Compressed Air............................................................................................................14
6. Commissioning the Synchroprint...............................................................................................15
7. Design and Operation.................................................................................................................15
7.1. General Process Description ...............................................................................................15
7.2. Overview Machine Parts.....................................................................................................16
7.3. Control panel.......................................................................................................................16
7.4. Safety Devices.....................................................................................................................17
7.5. Pallets ..................................................................................................................................18
7.6. Foot switch ..........................................................................................................................18
7.7. Main Power Switch.............................................................................................................18
7.8. Type Plate............................................................................................................................19
7.9. Print Stations .......................................................................................................................19
7.9.1. Overview Print Stations ...............................................................................................19
7.9.2. Squeegee Drive Motor .................................................................................................20
7.9.3. Squeegee/Print Arm.....................................................................................................20
7.9.4. Screen Adjustment/Micro-Registration .......................................................................20
7.9.5. Squeegee Stroke Length Adjustment...........................................................................20
7.9.6. Squeegee/Print Arm Lock............................................................................................20
7.9.7. Squeegee carriage speed & pressure controls..............................................................20

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 4 of 45
7.9.8. Dryer connector............................................................................................................21
7.9.9. Control Keypad............................................................................................................21
7.9.10. Squeegee Carriage....................................................................................................23
7.10. Additional equipment ......................................................................................................24
7.10.1. Flash Cure Units.......................................................................................................24
7.10.1. Flocking Devices......................................................................................................25
8. Danger Zones.............................................................................................................................26
9. Control of the Machine..............................................................................................................27
9.1. Starting up and shutting down the Synchroprint.................................................................27
9.1.1. Putting the Machine into Operation.............................................................................27
9.1.2. Switching the Machine Off after normal operation.....................................................28
9.1.3. Stopping the Machine in the event of an Emergency ..................................................28
9.1.4. Stopping the Machine in the event of Malfunction......................................................29
9.1.5. Long-term Shutdown ...................................................................................................29
9.1.6. Permanent Shutdown of the Machine..........................................................................29
9.2. Configuration of the Control...............................................................................................29
9.3. Menu Images.......................................................................................................................30
9.3.1. Adjust...........................................................................................................................30
9.3.2. Manually ......................................................................................................................34
9.3.3. Automatic.....................................................................................................................36
9.3.4. BasicSetup....................................................................................................................38
9.3.5. Help..............................................................................................................................39
9.4. Error messages ....................................................................................................................39
9.5. Blocked operation................................................................................................................40
9.6. Trouble shooting..................................................................................................................41
9.6.1. Error Messages control system ....................................................................................41
9.6.2. Basic errors (without error message) ...........................................................................42
10. Maintenance of the Synchroprint............................................................................................43
11. Terms of the Guarantee...........................................................................................................45
12. Limitation of liability..............................................................................................................45
13. Support, Customer Service and Hotline..................................................................................45

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 5 of 45
1. Safety Instructions
This section describes the safety instructions for the correct and safe operation of the Synchroprint
X-Type plus. In addition, this section also contains references to the European rules and regulations
concerning the guarantee of industrial safety along with safety at the workplace. These rules and
regulations provide the basis for these operating instructions.
These Operating Instructions include:
1. General safety instructions.
2. Special safety instructions, if they are relevant to a specific section, at the beginning of that
respective section.
3. Special safety instructions, if they are important for detailed sequences of operation, before
the description of that respective sequence of operation.
4. Indications to read such instructions included in the respective section.
1.1. Description of Key Words and Symbols in the Operating Instructions
In these operating instructions classified key words and symbols are used to identify dangers and
items that require special attention. Particular attention is to be paid to the sections marked in this
manner, because they contribute to personal safety as well as the prevention of damage to the
Synchroprint.
Symbol
Key word
Meaning
DANGER
This symbol indicates possible risk for life.
CAUTION
This symbol indicates danger of damage to
property and/or environment.
NOTE
This symbol indicates useful additional information
and operating suggestions.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 6 of 45
1.2. General Information
The Synchroprint X-Type plus (hereon named Synchroprint) is built in accordance to all
appropriate safety regulations. Owing to its complex design, the Synchroprint must only be
operated and maintained by suitably skilled staff.
Installation, operation or maintenance of the Synchroprint by persons who have not been suitably
trained, introduced or acquainted with the system and informed regarding the possible dangers may
result in:
1. Failure of essential functions of the Synchroprint.
2. Danger to persons through electrical or mechanical actions.
3. Material damage to the Synchroprint.
1.3. Qualification of Operating and Service Staff
‘Qualified personnel’ refers to people who are able to carry out the required procedures and be able
to recognize as well as prevent potential risks, as a result of their training and experience. Such
personnel should have a good knowledge of any relevant standards, regulations, rules of accident
prevention and internal conditions etc.
Every person instructed to perform any operation on the Synchroprint must:
1. Be physically and mentally capable of coping with the respective tasks.
2. Be suitably instructed in operating the Synchroprint.
3. Be familiar with the Operating Instructions, in particular the general safety instructions in
the individual sections, and have read and understood them.
4. Be aware of any additional general safety regulations of any local authorities/associations.
5. Be aware of the principles of industrial hygiene and be able to demonstrate them.
6. Be aware of the contents of suppliers’ safety instructions, should they affect his/her area of
responsibility.
7. Be aware of any relevant safety devices at the workplace and be able to use them.
8. Be informed regarding the prevention of environmental damage in respect of his/her area of
responsibility.
9. Be informed regarding the prevention of material damage in respect of his/her area of
responsibility.
If casual workers are employed for assistance work they must be particularly informed regarding
existing and potential dangers and instructed accordingly.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 7 of 45
1.4. Required qualification for operations
Skill
Assistant
Operating
personnel
Maintenance
personnel
Service
personnel
Colour refill (only at standstill)
x
x
x
x
Unloading substrates
x
x
x
x
Cleaning of the machine (only at standstill)
x
x
x
x
Setting screens
x**
x
x
x
Equip flood and print squeegees
x**
x
x
x
Equip the screens
x**
x
x
x
Adjust squeegees
x**
x
x
x
Clean of the screens in clean mode
x**
x
x
x
Equip machine with dryer or changing the position
x**
x
x
x
Applying substrates
x
x
x
Enable and disable printing heads
x
x
x
Enable and disable of dryer
x
x
x
Start of all printing processes and adjustment work
x
x
x
Activities at the maintenance unit
x
x
x
Lubricate of the machine
x
x
x
Shutting down the machine
x
x
x
Long-term shutdown
x
x
Permanent shutdown of the machine
x
x
Maintenance and repairs at the pneumatically system
x*
x
Maintenance and repairs at the electrical system
x*
x
Maintenance and repairs at the mechanical system
x*
x
Maintenance and repairs at additional units
x*
x
Maintenance and repairs at the electronically system
x
Maintenance and repairs at the safety system
x
* only with the required qualification
** only together with the operating personnel

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 8 of 45
1.5. Safety Instructions for the Operating Staff
All cabinets and covers on the Synchroprint must always be kept closed. Open
cabinets and covers are extremely dangerous as live electrical components are
accessible.
Mechanical or electrical failures must only be repaired by an MHM
authorized/approved technician.
On every occasion, the operator should check the correct functioning of the
safety devices (Emergency STOP), before commencing use of the Synchroprint.
No modifications to any part of the machine or its assembly system that may
adversely affect safety must be carried out without the prior approval of MHM.
Program modifications in the control program and changes of settings which
may affect the Synchroprint’s operation should only be carried out by an MHM
authorized/approved technician.
All working spaces, passageways, escape and emergency routes and exits must
be kept clear.
No tools or other objects must be kept or left in the area of the machine.
Any modifications or changes to the Synchroprint’s settings should only be
carried out by an MHM authorized/approved technician.
Always wear protective gloves and safety goggles during cleaning work, in
particular when using solvents!
Any remains of potentially harmful substances should be disposed of according
to the legal requirements of the country or state in which the Synchroprint is
operated.
All accessories for service and maintenance work (e.g. cleaning agents) must be
collected in suitable containers and disposed of according to any relevant
regulations.
1.6. Personal Protective Equipment
Personal protective equipment must be used at work. This equipment comprises close-fitting
working clothes with tight sleeves and high tearing resistance without any protruding parts. These
features prevent operators from getting caught by moving machine parts.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 9 of 45
1.7. Additional Risks
Even though the Synchroprint has been designed and built according to the most stringent safety
criteria, as with all machinery we have to anticipate certain additional risks, which are detailed
below:
Danger
Description
Behavior/Action
Electrical threats:
Indirect contact (in case of
defect)
Danger of life-threatening
electrical shock by indirect
contact with defective parts
carrying voltage (in particular
in case of defective insulation).
Switch off the machine with
the main switch and
EMERGENCY STOP
facilities. Isolate the mains
supply.
Mechanical threats:
Crushing
Crushing of parts of the body -
in particular arms and hands.
Be aware of moving parts
whilst operating the machine.
Wear protective clothing at all
times.
Mechanical threats:
Getting caught or trapped
Danger through moving parts
(linear or rotary drive
systems).
Danger in reaching into, under
or over the machine. Only
reach into the machine from
the indicated points. Wear
suitably fitting clothing,
particularly in the area of the
arms.
Mechanical threats:
Slipping, stumbling and falling
Danger of falling (e.g.
obstacles on the floor).
The floor area around the
machine must be kept free
from any obstacles.
Danger through contact with or
inhaling of substances
Danger through contact with or
inhaling substances or
materials with harmful or toxic
effects.
Observe the safety instructions
for handling such substances.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 10 of 45
1.8. Safety Signs on the Machine
The following safety signs are attached to the corresponding points of the machine:
Danger
Description
Location
Warning against squashing of parts
of the body, in particular arms or
hands.
At squeegee carriages.
Warning of dangerous voltage.
At current-carrying parts of the
machine with 230/400VAC.
The adhesive labels must be replaced if illegible (due to dirt or damage).
1.9. Other Valid Rules and Regulations:
The customer must comply with all regulations applicable in the country where the machine is
located.
2. Intended usage of the machine
The machine is intended for the printing of substrates (usually textiles such as T-shirts, but also
paper or similar materials) by means of screen printing. The substrates are conveyed by means of
the “carrousel system”. With the use of optional accessories the substrate can also be dried or
treated with other finishing techniques (e.g. flocking).
3. Data
This section details the Synchroprint technical specifications.
3.1. Serial Number and Year of Manufacture
Serial number and year of manufacture are indicated on the machine’s type plate.
NB: As our policy is one of continuous improvement, we reserve the right to
change specifications without prior notice.
Any other use of the machine than described above may result in danger to
persons or material damage and is therefore forbidden.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 11 of 45
3.2. Dimensions
3.3. Specifications
Specifications X-Type plus
SPXC 04
SPXC 08
SPCX 10
SPXC 12
SPXC 14
number of pallets
4
8
10
12
14
max. number of printstations / colors
3
6
8
10
12
max. image area (standard version)
43 x 50 cm (17 x 19,5")
max. image area (LS version)
43 x 55 cm (17 x 21,5")
max. frame size (standard version)
60 x 80 cm (23 x 31")
max. frame size (LS version)
66 x 92 cm (26 x 36")
overall diameter
320cm
126"
370cm
146"
410cm
161,5"
450cm
177"
490cm
193"
overall diameter LS version
350cm
137,8"
400cm
157,5"
440cm
173,5"
480cm
189"
520cm
205"
Machine weight (standard version) [kg]
1100
1700
1850
2000
2300
Machine weight (LS version) [kg]
1150
1750
1900
2050
2350
electrical supply
1 ph. ~ 200/240V AC, 50/60Hz (+/- 5%)
connected load (indexer)
1,6 kVA
connected load (per printstation)
0,4 kVA
Ø power consumption [kWh]
0,58
0,8
0,95
1,1
1,25
air pressure (minimum)
7 bar / 100 PSI (filtered, dry air only)
Ø air consumption (l/min)
130
220
280
340
400

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 12 of 45
4. Transportation and packaging
This section provides an overview of the proper transportation of the Synchroprint.
4.1. General Notes with Regard to Transportation and Danger Warnings
4.2. Packaging
The Synchroprint will be packed and delivered in several wooden crates. The crates’ exact number,
weight and dimensions will vary slightly according to each model/type of machine. Contact
customer service for more information about individual orders.
4.3. Unloading of the crates
The Synchroprint is to be unloaded by the customer. A forklift truck with adequate fork length and
lifting capacity (see 4.2 Packaging) will be required.
4.4. Packaging material
After unpacking the machine, the packaging material must be disposed of according to local
regulations.
Upon delivery of the Synchroprint the consignment must be examined for
external damage immediately. In the case of any damages, they must be
documented and reported to Machines Highest Mechatronic GmbH within 24
hours.
Danger of falling objects!
The following instructions must be observed
1. Never stand or walk under hanging loads!
2. Transportation must be carried out by qualified staff observing all safety
instructions.
3. The Synchroprint must only be lifted at the dedicated lifting points.
4. Only the lifting/handling devices and equipment indicated in this document
must be used for the movement of the Synchroprint. Non-compliance may
lead to serious damage of the Synchroprint and result in cancellation of the
warranty.
Danger of mechanical damage!
The Synchroprint must be lifted carefully and only at the dedicated lifting
points at the middle of the base unit. Lifting the Synchroprint at/by any other
point, especially the turntables, may result in serious damage. Be sure to
maintain an adequate and safe distance during lifting.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 13 of 45
5. Assembly
This section describes the external supply/connection ports of the Synchroprint and the points to be
observed during assembly.
5.1. General Assembly Instructions
The customer should have a minimum of two persons available to assist the technician with the
installation and assembly of the machine.
5.2. Positioning of the Synchroprint
The machine must be mounted on a bed with sufficient load-bearing capacity. In case of doubt this
capacity has to be examined by a structural engineer.
In order to guarantee perfect installation and smooth operation of the Synchroprint, the machine
must be installed at a sufficient distance from adjacent elements of the building (walls, columns,
etc.) and/or other machines. The distance required in each case depends on the screen size, and must
be chosen so as to allow the operator to replace the screens without any problems. The dimensions
of the respective machine are indicated in Chapter “3Data”.
5.3. Ambient Conditions
For the electrical equipment on the Synchroprint, ambient conditions according to standard IEC
60204 “Electrical Equipment of Industrial Machines” should be observed.
The following points should be observed in order to achieve efficient running and an optimum level
of production with the Synchroprint:
1. The premises, where the Synchroprint is to be operated, must be kept clean, dry and well-
aired.
2. The ambient temperature must not fall below +5° C or exceed +45° C.
3. Relative air humidity must not exceed 80 %.
4. The mains supply must not exceed or fall below a tolerance of +/- 5 % of the required
voltage for the Synchroprint. If this voltage stability cannot be guaranteed, the customer
must install a constant-voltage regulator to protect the Synchroprint against such
fluctuations.
5. The compressed air must be clean, filtered and dry (class 1:4:1 according ISO8573-1:2010).
6. Compressed air supply must be sufficient in terms of pressure, volume and consistency.
7. Electricity supply should be sufficient with adequate fuse protection.
8. Maximum installation altitude is 2000m above sea level.
The Synchroprint must only be installed / assembled by an authorized MHM
service technician or by an authorized service technician from an official
MHM dealer/agent. Any assembly/installation by any third party not listed
above will result in immediate cancellation of the warranty.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 14 of 45
5.4. External supply/Connection ports
Connections for compressed air and mains electricity are located on the base unit of the
Synchroprint as standard. Overhead supply connections may be ordered optionally but only at time
of order, to enable supplies to enter the machine from above, through the centre column.
5.4.1. Electrical Connections
The electrical connections must be designed as follows:
Description
Requirement/Value
Supply voltage
1 x 200-240 V
Supply frequency
50/60 Hz ±5 %
Connected load
1.6 kVA + (0.4 kVA x „number of print heads“)
(= “power for indexer main drive” + “power per print head” x
“number of print heads”)
5.4.2. Compressed Air
Description
X-Type plus
4/2
8/6
10/8
12/10
14/12
Max. air consumption (l/min)
130
220
280
340
400
Air pressure (minimum)
7 bar / 100 PSI
Air quality
filtered, dry air supply only
(class 1:4:1 according ISO8573-1:2010)
All flash cure units must be supplied through a separate/independent
connection. Please observe the precise technical data from the flash cure unit
specification sheet.
Risk of electric shock!
Please observe the general safety regulations for electrical connections when
connecting the mains supply to the Synchroprint. Avoid any contact with live
components.
Danger of tripping over!
In case of laying supply lines on the floor, it is necessary to attach step covers.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 15 of 45
6. Commissioning the Synchroprint
After the initial start-up of the machine, commissioning is to be completed in the presence of the
authorized technician along with any persons authorized on the part of the customer. During this
initial start-up and commissioning, all tasks carried out by the MHM service engineer or the
technicians of an authorized dealer are recorded.
This installation/job sheet must be clearly signed by both parties, stating the date and location of the
Synchroprint and will be legally binding hereon after.
7. Design and Operation
This section describes design and operation and indicates the individual assemblies.
7.1. General Process Description
The operator applies a substrate (usually a T-shirt or paper) to the pallets at the locating surface.
Textiles will be fixed in position by means of the spray adhesive applied to the pallets beforehand.
For paper a special vacuum model is necessary to hold the substrate on the pallet by means of
negative pressure. Subsequently, the carrousel moves the substrate to the first print station, where
the substrate is printed by means of screen printing or treated with optional accessories.
Subsequently, the substrate moves to the second station, where it is treated again, before the process
continues with all other stations. Finally, the substrate arrives at the unloading point, where an
operator takes it from the machine for further processing.
Initial start-up of the Synchroprint should only be carried out by an authorised
MHM service engineer or by an approved technician from an official MHM
dealer/agent.
Any defects or complaints must be brought to the attention of the authorized
technician, documented in writing and recorded immediately on the service
technician’s installation/jobsheet.
Before starting the machine, mains connection and compressed-air supply
must be checked and, if necessary, established according to the instructions.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 16 of 45
7.2. Overview Machine Parts
7.3. Control panel
Foot switch
Pallets
Print station
Safety bars
Safety cable
Control panel
Tablet
m-touch pro
EMERGENCY STOP
(push button)
Safety level key
Control
ON/OFF
Main switch
tablet
Power supply
tablet
Reset
button
Skip
button

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 17 of 45
The main control panel includes the following features:
Machine feature
Description
Tablet
m-touch pro
The tablet PC is used to control the main operating features of the
Synchroprint. Touching (tapping) the command buttons displayed on
the screen will operate various individual functions of the machine.
You will find a detailed description of all functions in section “9
Control of the Machine”.
Main switch tablet
Use “Main switch tablet” to switch the tablet on, off or to put it into
idle state. When the unit is on, push shortly to change into idle state.
After a longer push a menu will be displayed where the unit can be
switched off completely. To start the tablet a short push is enough. The
handling is similar to modern Smartphones.
Control ON/OFF
“Control ON/OFF” is used to switch the control power supply which
supplies all control components inclusive the tablet. To switch off the
main power use the main power switch.
EMERGENCY STOP
(push button)
The EMERGENCY STOP push button is part of the safety facility. See
section 7.4 Safety Devices.
Skip button
Press the Skip-Button when substrate is not applied in a correct way. In
this case the respective print station will not start to work and the
substrate will not be printed. The print process at other stations and
pallets will not be interrupted.
Reset button
To cancel a safety device shutdown first press the ERROR RESET
PUSH BUTTON and clear error message on tablet afterwards.
Safety level key
In operating mode ADJUST an automatic error resetting can be
activated with the safety level key; this is needed to adjust the machine
in case of certain adjustment procedures. This can be done by
switching the safety level key to position 1, in normal operation the key
must be in position 0. Only properly trained and appropriately qualified
personnel should use this function. The quick stop function of the turn
table is active all the time. Print and flood strokes can also be made at
active error situations, while a turntable index is prevented.
Power supply tablet
To load the battery of the tablet the power supply must be connected.
To prevent battery from discharging, press “Main switch tablet” shortly
to put tablet into idle mode. If this is not done, the tablet must be
restarted the next day.
7.4. Safety Devices
The safety devices serve as emergency stop facilities to avoid accidents and to guarantee safe
operation of the machine. The Synchroprint has the following safety devices:

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 18 of 45
Safety device
Description
EMERGENCY STOP
(push button)
Push button located at the main control panel. In case of emergency,
pressing the EMERGENCY STOP will stop all movements of the
machine. The function of the push button is cancelled by unlocking the
switch (turning it to the right).
Safety bars
Yellow/black bars located at the right and the left of the ‘load/unload’
area. Pressing any one of these bars will result in an immediate
EMERGENCY STOP of the machine. The location of these bars
ensures that the EMERGENCY STOP function is activated
automatically should a person become trapped between print station
and pallet.
Safety cable
The safety cable blocks the danger zone between two print stations.
When the cable is disconnected, an immediate EMERGENCY STOP is
activated.
7.5. Pallets
The substrates must be applied on the pallets. Depending on the substrate size, different pallets must
be used. By default pallets with format 40x80cm made of aluminum in honeycomb structure and a
thickness of 17mm are used. The maximum allowed pallet weight is 4kg.
7.6. Foot switch
The foot switch is used to start an index movement when machine runs in manual mode. In
automatic mode the index movement can be blocked.
7.7. Main Power Switch
The main power switch is mounted at the machine’s basic frame. It disconnects the machine from
the main supply voltage immediately.
These safety devices must not be used to switch off the machine under normal
operation. Any EMERGENCY STOP presents an exceptional loading to the
servo-motor and transmission etc. Excessive use will result in damage to the
machine along with subsequent cancellation of the warranty.
Exceeding the maximum allowed weight of the pallets would increase the
dynamic load to the machine and can cause material damage. The maximum
weight of the pallets must be observed.
Only pallets provided by MHM must be used for production.

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 19 of 45
7.8. Type Plate
The type plate with type, serial number, year of manufacture, mains voltage, mains frequency,
connected load and CE symbol is located on the machine base.
7.9. Print Stations
7.9.1. Overview Print Stations
The print stations are used for printing individual colors onto textiles/garments. The X-Type plus
may be ordered with a maximum of up to 12 print stations. The following sections include a
detailed description of the individual components.
Squeegee
drive motor
Squeegee carriage
Squeegee/print arm
Squeegee stroke
length adjustment
Screen adjustment
Left/right - rear
Screen adjustment
Forward/backward
Control keypad
Squeegee carriage speed &
pressure controls
Squeegee/print arm lock-down
X-axis
Y-axis
Screen adjustment
Left/right - front
hinten
Dryer connector

Operating Instruction X-Type plus
Operating instructions X-Type plus V1-3.docx Page 20 of 45
7.9.2. Squeegee Drive Motor
The squeegee/print arm motor is used to drive the squeegee carriage back and forth, precisely
controlled by the frequency converter.
7.9.3. Squeegee/Print Arm
The squeegee carriage, squeegee stroke length adjustment, control keypad and control knobs for the
squeegee carriage speed & pressure are all located on the squeegee arm.
7.9.4. Screen Adjustment/Micro-Registration
The screen adjustment/micro-registration is used for the precise positioning of the screens. Each
screen may be positioned forwards/backwards by means of a single handwheel adjuster located at
the front of each individual print station. For left/right adjustment there are two handwheel adjusters
located at the front and rear of each individual print station. Adjustment is free from play and self-
locking, therefore no additional clamping is required.
7.9.5. Squeegee Stroke Length Adjustment
The squeegee stroke length adjustment may be used to adjust the precise travel of the squeegee
carriage. There are individual sensors on each print station to adjust the front and rear positions.
Minimizing the travel of the squeegee carriage helps to reduce printing times and increase
production.
7.9.6. Squeegee/Print Arm Lock
Pressing the squeegee/print arm lock moves the entire squeegee/print arm upwards, providing un-
obstructed access to the screens.
7.9.7. Squeegee carriage speed & pressure controls
1… Adjustment for squeegee carriage speed forwards
2… Adjustment for squeegee carriage speed backwards
3… Adjustment for squeegee pressure (with clear display gauge)
1
2
3
Table of contents
Other MHM Printer manuals
Popular Printer manuals by other brands

CIM
CIM PRO THERMAL 2000 Operator's manual

Epson
Epson Stylus Pro 7880 ColorBurst Edition - Stylus Pro 7880... user guide

Epson
Epson C11CA27201 - WorkForce 40 Color Inkjet... Specifications

BIXOLON
BIXOLON SRP-352plusIIA&C installation guide

Canon
Canon PIXMA MX340 Series Simplified service manual

NCR
NCR 719 II Series CLEANING