DIGITAL MICROMETER IP65
USER MANUAL
1μm
IP65
ISO 17025
calibration
HOLD
function
FRICTION
thimble
ISO 9001:2015
ISO17025:2017
MICROTECH SPECIFICATION
Item No Range Resolution Accuracy Dimensions Micrometer
head
Protection
class
C L B D
mm inch mm
μ
mmm mm mm mm
110180254 0-25 0-1”
0,001
±2 24 32 7 2
friction
IP65
110180504 25-50 1-2” ±2 33 56 8 2 IP65
110180754 50-75 2-3” ±2 48 85 12 2 IP65
110181004 75-100 3-4” ±3 60 112 12 2 IP65
110181254 100-125 4-5” ±4 73 135 14 2 IP65
110181504 125-150 5-6” ±4 86 160 16 2 IP65
DOUBLE RANGE MICROMETER
110180514 0-50 0-2” 0,001 ±3 33 56 8 2 friction IP65
110181014 50-100 2-4” ±4 60 112 12 2 IP65
SET
Resetting zero
in absolute measurements
HOLD
Hold measured value.
On /Off the measurement
results to external socket
UNIT
Switching between metric
and English measurement
systems
Long press for Swicth off
0/MODE
Switching on. Switching
between absolute and relative
measurements. Resetting zero in
relative measurements.
FUNCTION
MICROTECH
OPERATION
FUNCTION
1.Clean the oil from the measuring surfaces of micrometer by cloth.
2.If necessary, open the battery cover; insert the battery (type CR2032)
according to the polarity of the electrodes. Blinking display information
or absence suggests replacing battery. After battery replacement on the
screen will be ---------- indication. Press SET button for setting 0.000 .
3 Turn on the display by pressing 0/MODE button.
4 Check the setting display to zero. Contact with each other (or with setting
gauge) measuring surfaces of the anvil and the spindle, using the ratchet
and take a measurement.
Rotation the micrometer screw in the direction of convergence measuring
surfaces using the ratchet.
ip located at the end of screws, used only for reverse spindle.
5 For zero setting, press the O/MODE or SET button and hold it to reset to
Zero.
6 After switching on, the display shows the measured value of the metric/
English system of units. Press UNIT button to switch between metric/
English measurement systems.
7 After switching on, the display shows in absolute or relative terms. Press
O/MODE button to switch between absolute and relative measurement
8 During measure, thimble should rotate only by ratchet. Ensure contact of
workpiece with measuring surfaces of the micrometer so tightly to ratchet
cranked 2-3 times. Try to prevent warping measuring surfaces.
9 This micrometer has auto switch off function (10 min non using) ot press
UNIT button during 2 sec. to switch off.
10 After work the measuring surfaces of the micrometer wipe with a cloth
and apply anticorrosive oil.
WARNING !
- Avoid contact with the body electronics unit micrometer emulsions and oils.
- During the measurements, periodically check the zero setting micrometer.
- Do not make the rotation of the micrometer screw in close measuring surfaces using a thimble.
- Avoid shocks or falling, even with a small height.
- Do not disassemble or adjust the micrometer persons who unrelated to the repair.
MICROTECH
Change without prior notice
MICROTECH
innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39
tel.: +38 (057) 739-03-50
www.microtech.ua
[email protected]

This manual suits for next models

7

Other Microtech Measuring Instrument manuals

Microtech 120126131 User manual

Microtech

Microtech 120126131 User manual

Microtech 110181027 User manual

Microtech

Microtech 110181027 User manual

Microtech 14109805 Series User manual

Microtech

Microtech 14109805 Series User manual

Microtech 1106500258 User manual

Microtech

Microtech 1106500258 User manual

Microtech SUB-MICRON 1250511006 User manual

Microtech

Microtech SUB-MICRON 1250511006 User manual

Microtech e-DIAGNOSTIC User manual

Microtech

Microtech e-DIAGNOSTIC User manual

Microtech 110180027 User manual

Microtech

Microtech 110180027 User manual

Microtech 120125131 User manual

Microtech

Microtech 120125131 User manual

Microtech 110184008 User manual

Microtech

Microtech 110184008 User manual

Popular Measuring Instrument manuals by other brands

Acoustical Systems UNI P2S owner's manual

Acoustical Systems

Acoustical Systems UNI P2S owner's manual

Sanding STS-752RC user manual

Sanding

Sanding STS-752RC user manual

PestWest UV-AMETER instructions

PestWest

PestWest UV-AMETER instructions

RBR RBRduo3 C.T/uv quick start guide

RBR

RBR RBRduo3 C.T/uv quick start guide

hager KJ10S Mounting instructions

hager

hager KJ10S Mounting instructions

CYP CPHD-V4 Operation manual

CYP

CYP CPHD-V4 Operation manual

Ametek Thermox WDG-V user manual

Ametek

Ametek Thermox WDG-V user manual

Spirax Sarco ILVA20 Installation

Spirax Sarco

Spirax Sarco ILVA20 Installation

Qstarz Explore 2000 Quick installation guide

Qstarz

Qstarz Explore 2000 Quick installation guide

Camille Bauer LINAX PQ3000 operating instructions

Camille Bauer

Camille Bauer LINAX PQ3000 operating instructions

FLIR MSX MR277 user manual

FLIR

FLIR MSX MR277 user manual

Precision Digital Corporation PROVU PD7000 instruction manual

Precision Digital Corporation

Precision Digital Corporation PROVU PD7000 instruction manual

Skyrc NC2500 Pro instruction manual

Skyrc

Skyrc NC2500 Pro instruction manual

Dytran 3122C operating instructions

Dytran

Dytran 3122C operating instructions

LATNEX MG-2000T manual

LATNEX

LATNEX MG-2000T manual

Avisoft ULTRASOUND GATE user guide

Avisoft

Avisoft ULTRASOUND GATE user guide

Keithley SourceMeter 2611 user manual

Keithley

Keithley SourceMeter 2611 user manual

Hanna Instruments HI 99131 instruction manual

Hanna Instruments

Hanna Instruments HI 99131 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.