REV. DOCUMENT N° DESCRIPTION ZONE DATE DRAWN CHECKED
This drawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAM LIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000 Date
1:2 2/2
Description Scale Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approved by Weight Rev.
Modus R 1000
INSTALLATION GUIDANCE v1.0

3
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
2
Contents
Prior to starting the installation, check the equipment list
to be sure of using the correct tools (mounting screw(s)
and nut(s) are not supplied).
24 mm standard wrench for M16 screws
30 mm standard wrench for M20 screws
#8 allen key
Powered drill-screwdriver with adjustable
torque (clutch)
Torx T25 insert bit for powered screwdriver (to be
used with M5 screws)
Torx T25 manual screwdriver
Torx T30 insert bit for powered screwdriver (to be
used with M6 screws)
Torx T30 manual screwdriver
Monkey pliers
Electrician scissors for wires
Ph2 screwdriver
Slotted manual screwdriver for connector’s
screws (blade dimensions: 3.5(w) x 0.6(t)mm)
Wire stripping pliers
DO NOT USE PERCUSSION DRILLS!
Equipment list
Wear adequate working gloves, safety shoes and
hard hats to protect yourself from falling material
Never energize the lamp if wiring operation are not
completed
H&S check
1. General notes
Section PAGE
1 General notes 3
2 Safety instructions 4
3 Contents 5
4 Bracket mounting and aiming 6
5 Visor mounting 7
6 Electrical connection 7
7 Floodlight connection 8
7a Floodlight connection with connector 9
7b Floodlight connection without connector 14
8 Power supply connection 17
9 Control connection Dali 19
10 Control connection 0-10V 20
11 Cabinet driver 21
This user manual contains important information on safe operation of the Luminaire.
Read and follow all safety notes and all instructions. Save this manual for future reference.
Make sure that it is available to all persons using this device.
All wiring should be done by a licensed electrician in accordance with state codes, local codes, and National Electric
Code (NEC) standards or International Electrotechnical Commission (IEC) standards.
The Luminaire is suitable for wet locations.
This luminaire must only be replaced by the manufacturer, by its service staff or by qualified personnel.
The luminaire is suitable for outdoor use
IP66: The product is protected against powerful water jets.
DO
Store the luminaire with care, avoiding placing the lenses on the ground, which may scratch or damage them
Keep the luminaire in the original packaging when storing to avoid damage
When handling the Luminaire, wear industrial safety gloves and safety boots
Operate on circuitry when the electrical power supply is disconnected
DO NOT
Apply mains voltage through the control system cable. This will damage the luminaire and it will no longer be
covered by warranty
Unnecessarily remove the luminaire from the box
Leave the LED luminaire switched on when resting on the ground with optics facing down
Place the luminaire with the lens on the ground, dirty or metal surfaces
Clean the lenses with any industrial detergent. Use a water-soaked cloth if needed
12 Driver/floodlight pairing 22
13 Electrical specifications 22
14 Weight and Windage 22
15 Dimensions 23

4 5
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
2. Safety instructions
Use the device only as described in this user manual.
Any other use or use under other operating conditions
is considered to be improper and may result in personal
injury or property damage as well as voiding the warranty.
This product meets all legal requirements for CE marking
This device is subject to the European directive 2002/96/EC.
Do not dispose of the device with your normal household waste. Dispose of this
device through an approved waste disposal firm or through your local waste
facility. Comply with the rules and regulations that apply in your country. If in doubt,
consult your local waste disposal facility.
No liability will be assumed for damages resulting from
improper installation.
Only persons with sufficient physical, sensorial, and
intellectual abilities and having corresponding knowledge
and experience may use this device.
Contains parts and
assemblies susceptible to
damage by electostatic
discharge (ESD)
The Luminaire should be
positioned so that prolonged
staring into the luminaire at
a distance closer than 19m
(63 ft) is unlikely
The light source of this
appliance must only be
replaced by the manufacturer,
its after-sales service or
qualified personnel
The minimum safety distance
from illuminated object to
avoid any damages is 1 m.
The luminaire is not to be
placed face down on any
surface other than the
provided foam pad
Risk of electric shock
Disconnect the electrical
power supply before
commencing the installation:
failure to do so could result in
serious injury
Hard Hats, Safety shoes,
Hi-Vis vest and Safety
Gloves must be worn
at all times
Do not use a
generator!
Two persons
required to complete
the installation
1m
Waiver: This document represents information
compiled to the best of our present knowledge. It is
not intended to as a representation or warranty of
fitness of the products described for any particular
purpose. This document details guidelines for
general information purposes only. Always seek
specialist advice when planning installations and
ensure the installation is carried out by a properly
qualified installer.
Modus R 1000 LED floodlight
Remote driver x1
(for outdoor or cabinet installation)
Visors with screws and washers
Caribiner hook and cable
3. Contents
1
R
234567 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Q
P
O
N
M
L
I
H
G
F
E
D
C
B
A
12 3 4567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I
L
M
N
O
P
Q
R
G
F
E
D
C
B
A
H
MIDSTREAM
REV. DOCUMENT N° DESCRIPTION ZONE DATE DRAWN CHECKED
This drawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAM LIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000 Date
1:2 2/2
Description Scale Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approved by Weight Rev.

6 7
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
2. Insert screws
Insert each screw with its plain washer and spring washer
through the central hole of the fitting bracket flange and
slightly tighten.
You will need to rotate the bracket with ease to adjust the
tilt.
4. Mounting
When the LED luminaire installation has been completed,
secure the floodlight to the mounting structure via the
safety cable.
Connect the safety cable to the holding frame with the
supplied carabiner hook.
1. Angled bracket
The floodlight is equipped with an angled bracket that
has a central hole for an M20 screw (tightening torque
250 Nm) and two slots for M16 screws (tightening torque:
150 Nm).
3. Adjusting angle
The LED luminaire can be tilted at 5° intervals using the
notches on the frame and the references on the bracket.
Once the tilting operation is complete, tighten and lock
the screws (tightening torque: 60 Nm).
1
R
234567 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Q
P
O
N
M
L
I
H
G
F
E
D
C
B
A
12 3 4567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I
L
M
N
O
P
Q
R
G
F
E
D
C
B
A
H
MIDSTREAM
REV. DOCUMENTN° DESCRIPTION ZONE DATE DRAWN CHECKED
Thisdrawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAMLIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000 Date
1:2 2/2
Description Scale Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approved by Weight Rev.
1
R
234567 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Q
P
O
N
M
L
I
H
G
F
E
D
C
B
A
12 3 4567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I
L
M
N
O
P
Q
R
G
F
E
D
C
B
A
H
MIDSTREAM
5°
5°
REV. DOCUMENTN° DESCRIPTION ZONE DATE DRAWN CHECKED
Thisdrawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAMLIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000
Date
1:2
2
/
2
Description Scale
Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approvedby
Weight
Rev.
SEE DETAIL
A
1
A
2 3 456 7 8 9 10 11 12
B
C
D
E
F
G
H
1 2 3 4 5 67 8 9 10 11 12
H
G
F
E
D
C
B
A
MIDSTREAM
1.6 0.83.2
( )
REV. DOCUMENT N° DESCRIPTION ZONE DATE DRAWN CHECKED
Thisdrawing is property of MIDSTREAM LIGHTING LTD. Allrights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAMLIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207584 8310
ST00120P002A0_INST
3/3
3:10
DrawingNumber
Sheet Scale
TITAN320-420_BRACKET
A1
A0
DESCRIPTION
Format Rev.
PA CP
MIDSTREAM
22-Apr-21
Drawingby Checked by
Date
VEDI NOTA SOPRA / SEE NOTE ABOVE
Approved by
TREATMENT
Weight Kg
S275JR (Fe 430 B) SP. 4mm
Roughness
MATERIAL
precise
0.05 0.1 0.15 0.2 0.3 0.5 - -
Angles 30°
Allmaterials employed
have to be selected
amongRoHS compliant
materials:
theEC directives
tobe referred to are
2002/95/ECand
correlatedsubsequent
ones.
medium
x
0.1 0.2 0.3 0.5 0.8 1.2 23
Shaft h11
coarse
0.2 0.5 0.8 1.2 2345
Holes H11
Tolerance class
upto
6
over6
upto 30
over 30
upto120
over120
upto315
over315
upto1000
over1000
upto2000
over2000
upto4000
over
4000
Lead screws 6H / Screws 6g
ISO Metric Screw
DIMENSIONS WITHOUT TOLERANCE DEGREE:
1
R
2345 67 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Q
P
O
N
M
L
I
H
G
F
E
D
C
B
A
12 3 4567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I
L
M
N
O
P
Q
R
G
F
E
D
C
B
A
H
MIDSTREAM
5°
5°
REV. DOCUMENTN° DESCRIPTION ZONE DATE DRAWN CHECKED
This drawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAM LIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000 Date
1:2 2/2
Description Scale Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approved by Weight Rev.
SEE DETAIL A
4. Bracket mounting and aiming
Use A2-80 stainless steel bolts or 8.8 class
steel bolts with hot dip Galvanised coating
Do not use percussion drills
5. Visor mounting
Secure visor
Mount a visor on each LED module.
The visor must be secured with the
supplied screws along with the plain
and serrated washers as shown.
Tightening torque: 7-8 Nm.
The shape of the visors may vary.
The cables for floodlight connection and power
connection must have 3 conductors (max. diameter 13.5
mm, suggested section 1.5 mm2).
Use a cable with 2 conductors for 0-10 V, DALI control
connection (max. diameter 12 mm, suggested section
1.5 mm2).
On floodlights with an outdoor driver, secure the control
plug with the supplied closure cap when the control
system is not in use.
A Control cable – 0-10 V, DALI (not supplied)
B Mains cable – power connection (not supplied)
6. Electrical connection
Use a main circuit breaker
with a rated current of
at least 25A
Do not apply mains voltage
through the control sytem
cable. This will damage
the luminaire.
1
R
234567 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Q
P
O
N
M
L
I
H
G
F
E
D
C
B
A
12 3 4567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I
L
M
N
O
P
Q
R
G
F
E
D
C
B
A
H
MIDSTREAM
5°
5°
REV. DOCUMENT N° DESCRIPTION ZONE DATE DRAWN CHECKED
Thisdrawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAMLIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000 Date
1:2 2/2
Description Scale Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approvedby Weight Rev.
SEE DETAIL A
BA
1
R
234567 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Q
P
O
N
M
L
I
H
G
F
E
D
C
B
A
12 3 4567 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I
L
M
N
O
P
Q
R
G
F
E
D
C
B
A
H
MIDSTREAM
5°
5°
REV. DOCUMENT N° DESCRIPTION ZONE DATE DRAWN CHECKED
Thisdrawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without express consent.
MIDSTREAMLIGHTING LTD - 1 CHESHAM STREET - LONDON - SW1X 8ND - UNITED KINGDOM - Ph +44 207 584 8310
Drawing Number MODUS_R_1000_V2 22-Apr-21
MODUS R 1000 Date
1:2 2/2
Description Scale Sheet
PA CP MIDSTREAM 20 Kg 0
Drawing by Checked by Approvedby Weight Rev.
SEE DETAIL A

8 9
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
30
9
Stripping the cable
Strip one end of the floodlight connection cable to a
length of circa 30 mm, then expose the conductors for
9mm.
(The cable from the driver to the floodlight is not supplied,
the cable used must be an outdoor rubber cable
H05RN-F or equivalent.)
The device has a type Y attachment. If it becomes
damaged, it should only be replaced by the manufacturer
or by its service staff.
Take a TH405 Connector socket. The connector and its
housing are supplied in 2 pieces.
SCALE 1:2
SEE DETAIL A
7. Floodlight connection 7a. Floodlight connection with an IP68 connector
Unscrew the cover
Unscrew the 4 x M5 screws. Then remove the plastic cap from the connector plug, push towards the connector side
and remove the cover.
Connecting via cable gland
Remove the 2 countersunk screws to remove the junction box lid. Insert the cable for the floodlight through the cable
gland. Remove the cable sheath for 65 mm to facilitate connection of the wires.
SCALE 1:2
SEE DETAIL A
Cable gland
Adapting the grommet
Remove the inside part of the grommet, when the cable
diameter is greater than 9 mm. To remove the gasket,
remove cable gland nut rst.
Follow these instructions to connect the oodlight via IP68 connector, to connect the oodlight with direct wiring skip
to page 14.

10 11
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
7a. Floodlight connection with an IP68 connector
Inserting the terminal into the socket
Rotate the 3-pole terminal into the shown position to insert into the socket. Then push and rotate counterclockwise
until you hear a click. The click means the terminal is properly locked into the socket.
Stripping the cable
Insert the cable through the connector housing.
The socket has L, N, earth symbols. Match as follows:
Live BROWN wire
Neutral BLUE wire
Earth symbol YELLOW/GREEN wire.
Insert the exposed wires in the plug and tighten each
screw.
Pull the wires to check if they are well tightened
SCALE 2:1
XSEC0001-XSEC0001SECTION
7a. Floodlight connection with an IP68 connector
Inserting the cable with plug connector into the oodlight junction box
To connect the accessory provided (cable + plug connector) to the junction box, remove the junction box cover and
the junction box lid. Untighten the cable gland with the plastic cap and remove it.
Tighten the nut
Tighten the plastic nut with a 24 mm wrench key.
CH24mm
Nm2.5÷4

12 13
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
Connect the plug and socket
Connect the plug to the socket. The arrow on the plug and the arrow on the socket must face each other.
Secure the connection
Rotate the outer part of the socket clockwise, then
push the red clip to the locked position to secure the
connection. If unlocking is required, use a screwdriver to
pull the clip to an unlocked position.
Warning
Do not pull the cables during installation. Do not bend the
cables more than the minimum bending radius - 5 to 8
times of the diameter of the cable.
SCALE 1:2
SEE DETAIL
A
Connecting the WAGO terminals
Insert the cable with the connector through the cable gland and connect its wires to the wago terminals as follows:
BROWN (+) wire that has the + sticker
BLUE (-) wire that has the - sticker
YELLOW&GREEN (GND) YELLOW&GREEN wire
Firmly tighten the cable gland, close the junction box lid, and mount the junction box cover back in position. Make sure
everything is properly tightened.
7a. Floodlight connection with an IP68 connector 7a. Floodlight connection with an IP68 connector
The cable with the
IP68 connector
To the lid
Floodlight Junction Box

14 15
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
7b. Floodlight connection without a connector
Inserting the cable into the oodlight junction box
To directly wire the oodlight head using the cable coming directly from driver’s output side, remove the junction box
cover and the junction box lid. Loosen the cable gland with the plastic cap and remove it
Connecting the WAGO terminals
Insert the cable with the connector through the cable gland and connect its wires to the wago terminals as follows:
BROWN (+) wire that has the + sticker
BLUE (-) wire that has the - sticker
YELLOW&GREEN (GND) YELLOW&GREEN wire
Firmly tighten the cable gland, close the junction box lid, and mount the junction box cover back in position. Make sure
everything is properly tightened.
7b. Floodlight connection without a connector
To the lid
To the lid
The cable coming directly from
the drivers OUTPUT
Warning
Do not pull the cables during
installation. Do not bend the
cables more than the minimum
bending radius - 5 to 8 times of
the diameter of the cable.
Floodlight Junction Box
Floodlight Junction Box

16 17
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
DRIVER
OUTPUT
CABLE
DRIVER
INPUT
CABLE
TO LID
OUTPUT CABLE
(to floodlight)
DRIVER
INPUT
CABLE
TO LID
7. Floodlight connection
Connecting the WAGO terminals
Connect the YELLOW-GREEN wire to the 5-way WAGO terminal.
Connect the BROWN wire to the WAGO terminal that has already a brown wire with a “+” sticker. Connect the BLUE
wire to the WAGO terminal that has already a blue wire with a “-” sticker.
Connect the YELLOW-GREEN wire to the 5-way WAGO terminal. Close the void position as well, even if there is no
wire connected.
51
60
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
DRIVER
OUTPUT
CABLE
DRIVER
INPUT
CABLE
OUTPUT CABLE
(to floodlight)
MAINS CABLE
TO LID
Remove the cable sheath for a length of 60 mm, expose
the conductor for 9 mm and insert the mains cable
through the cable gland through the cable gland labelled
with "POWER IN" sticker.
Connect the BROWN wire to the 2-way WAGO terminal
that has already a brown wire with an 'L' sticker.
Connect the BLUE wire to the 2-way WAGO terminal that
has already a blue wire with an 'N' sticker. Tighten the
M20 cable gland (torque: 8 Nm).
8. Power supply connection
Driver Junction Box
Driver Junction Box
Driver Junction Box

18 19
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
8. Power supply connection
Gasket must be properly
positioned to create seal
Checking the gasket
Check that the gasket is properly positioned inside the lid, then close the junction box.
Secure it with 2 countersunk screws (gradually tighten them, do not tighten sequentially).
WARNING: if the gasket is wrongly positioned or screws are loose, water may get into the junction
box.
Place the cover back on the driver unit and the cap on the control plug if not needed.
9. Control connection DALI
Strip the rubber jacket of the cable, expose 25 mm of
conductors. Mount the TH384 – socket connector.
Match
L RED conductor (+ pole / DA+)
N BLUE conductor (- pole / DA-).
Tighten the screws and pull each wire to check if they are
well clamped. Conductor colors may vary.
Remove the plastic cap to plug the control cable (2 poles,
yellow connector).
Insert the socket into the connector housing. Tighten the
plastic nut to seal the cable with the connector grommet.
25

20 21
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
10. Control connection 0-10V
Strip the rubber jacket of the cable, expose 25 mm of
conductors. Mount the TH384 – socket connector.
Match
Remove the plastic cap to plug the control cable (3 poles,
white connector).
Insert the socket into the connector housing. Tighten the plastic nut to seal the cable with the connector
grommet.
25
Dim
+
Dim
-
12v
11. Cabinet driver
Outdoor layout Cabinet layout
Input cable (mains)
Output cable
Control cable
INPUT cable: this cable power supplies the driver. Its 3 wires must match these connections:
Brown L / L1
Blue N / L2
Yellow & Green Ground
OUTPUT cable: this cable power supplies the floodlight. This cable has 2 wires: brown (+) and blue (-). The connection
must be done in such a way that the 2 wires match these poles on the floodlight connector on the top of the mast:
Brown L (or + if you don't use the IP68 connector)
Blue N (or - if you don't use the IP68 connector)
CONTROL cable: this cable controls floodlight output through the control system. This cable has 3 wires: purple
(dimming +), grey (dimming - ) and black & white (12V aux). The connection has to be done in such a way that the 3
wires match these poles inside your cabinet:
Purple Dimming +
Grey Dimming -
Black & White 12 V Auxiliary output voltage (only if needed)
L BROWN conductor
(Dimming + pole)
NBLUE conductor
(Dimming - pole)
Ground pole 12 V aux wire
Tighten the screws and pull each wire to check if they are
well clamped. Conductor colours may vary.

22 23
midstreamlighting.com call +44 (0) 207 584 8310MODUS R 1000 INSTALLATION GUIDANCE
13. Electrical specifications
12. Driver/floodlight pairing 15. Dimensions
14. Weight and windage
Modus R 1000
Input Voltage 200-480V ac
Input Frequency 50 – 60 Hz
Absorbed Power 1000 W
Power Factor 0.97
Inrush Current 37.5 A2s - for 1.18 ms*
Modus R 1000 Outdoor driver Cabinet driver
Weight 20kg 9kg 6.5kg
Windage 0.209m2 _ _
Floodlight name Floodlight code Driver code
Modus R 1000 MR10xxxxxEUxxxxx MDEU12xx54
Modus S 900 MS09xxxxxEUxxxxx MDEU12xx54
Modus S 1100 MS11xxxxxEUxxxxx MDEU12xx60
Modus R 1200 MR12xxxxxEUxxxxx MDEU12xx70
Modus R 800 MR08xxxxxEUxxxxx MDEU12xx74
* at 220 V ac input, 25°C cold start, 10% Ipk – 10% Ipk
Modus R 1000 Floodlight
Modus R – Outdoor driver (cabinet driver is the same without metalwork: 280 x 230 x 76 mm)
478
432
593
398
152
230
182
202
176
16
96.2
30
90 17
21
SCALE 1:5
478
432
593
398
152
230
182
202
176
16
96.2
30
90 17
21
SCALE 1:5
478
432
593
398
152
230
182
202
176
16
96.2
30
90 17
21
SCALE 1:5
When you need to install multiple Midstream remote
drivers and different models of floodlights with a different
power range, please make sure you pair the floodlight
with its correct driver.
Please follow the instructions shown on the labels. Floodlights and drivers must be paired according to the table below:
USE WITH
(driver code)
Only
USE WITH
(floodlight name)
Only
Label on floodlight head box Label on driver box
Drivers may have a different current set-up according to
the version / power of the floodlight.
A label on the product box identifies the item with which
the product must be paired.

24 MODUS R 1000 INSTALLATION GUIDANCE
2020
For translations, digital versions or more information go to
www.midstreamlighting.com/installation-guides
European HQ
Midstream Ltd. Wessex House, 1 Chesham Street, London SW1X 8ND, United Kingdom
US HQ
Midstream Lighting Ltd. 66 West Flagler Street, Miami, FL 33130, USA
midstreamlighting.com
Table of contents
Other Midstream Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Ledra Brands
Ledra Brands ALPHABET NU3RD installation instructions

LCG
LCG MOLEFAY 4A user manual

EuroLite
EuroLite BLACK GUN E-40 user manual

MA lighting
MA lighting dot2 XL-F Getting started guide

Lamphus
Lamphus SolarBlast SBLS14 instruction manual

dun-bri GROUP
dun-bri GROUP DBG M33 Series Installation & operating instructions