Technisches Datenblatt / Technical datasheet: PW 6137 EL
Datum / Date: 12.10.2011 Seite / Page: 9
1. Standard voltage (as supplied)
Connection cable, min. cross-section
Connection cable (not supplied)
1. Standard voltage (as supplied)
Connection cable, min. cross-section
Connection cable (not supplied)
Alternative voltage (convertible)
Connection cable, min. cross-section
Connection cable (not supplied)
Standard voltage (as supplied)
Connection cable, min. cross-section
Connection cable (not supplied)
Electrical connection must comply with national legis-
lation, guidelines and ordinances as well as local
regulations. Guidelines issued by power utilities and
insurance companies, occupation safety regulations
and general good practices also apply.
Connection should only be performed by a qualified
person with suitable training.
The machine can be hard-wired or installed with a
plug connection according to IEC 60309-1. A wall
socket or mains isolator must be accessible after
installation.
A plug and socket connection is recommended to
facilitate accessibility for electrical safety tests.
If an earth-leakage circuit breaker (RCD) is required
by local regulations, a Type B device (sensitive to all
types of current) should be installed.
Sleeve with external thread
Fitting such as washers and nuts are only supplied
with the OS machine version.
If necessary, equipotential bonding with good galvan-
ic contact must be provided in accordance with all
appropriate national and local regulations.
Connection voltage for control signals
Connection cable, min. cross-section
Connection cable (not supplied)
Miele recommends the use of a flexible supply lead
and an additional cut-off switch. The switch should be
visible and accessible after installation.