manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Milltronics
  6. •
  7. Measuring Instrument
  8. •
  9. Milltronics AIRANGER DPL PLUS User manual

Milltronics AIRANGER DPL PLUS User manual

Other manuals for AIRANGER DPL PLUS

1

Other Milltronics Measuring Instrument manuals

Milltronics IQ Radar 160 User manual

Milltronics

Milltronics IQ Radar 160 User manual

Milltronics ILE-37 User manual

Milltronics

Milltronics ILE-37 User manual

Milltronics airanger XPL plus User manual

Milltronics

Milltronics airanger XPL plus User manual

Milltronics miniranger plus User manual

Milltronics

Milltronics miniranger plus User manual

Milltronics MultiRanger Plus User manual

Milltronics

Milltronics MultiRanger Plus User manual

Milltronics COMPUFLO III User manual

Milltronics

Milltronics COMPUFLO III User manual

Milltronics Mercap MCP01 S series User manual

Milltronics

Milltronics Mercap MCP01 S series User manual

Milltronics HydroRanger I User manual

Milltronics

Milltronics HydroRanger I User manual

Milltronics MultiRanger Plus PL-513 User manual

Milltronics

Milltronics MultiRanger Plus PL-513 User manual

Milltronics HydroRanger Plus User manual

Milltronics

Milltronics HydroRanger Plus User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPERATION
When the Quick Start procedure is complete...
1.
"----" is displayed briefly...
The AIRANGER DPL PLUS rapidly takes measurements,
verifies repeatability, and calculates Readings.
For one vessel, the Reading is displayed continuously.
For two vessels, Readings are scroll displayed.
Difference or Average Readings (if selected) are also scroll
displayed, as Point Number 3.
The Bar Graph indicates material level (0 to 100%),
regardless of the Operation selected.
If "▲" is displayed the vessel level has exceeded 80% and
not yet fallen below 75% (Hi Alarm).
If "▼" is displayed the vessel level has fallen below 20% and
not yet exceeded 25% (Lo Alarm).
When in alarm, the corresponding relay is de-energized.
2.
Readings are displayed in % (based upon Operation).
level space or distance
Empty ➞Span = 0 ➞100% Empty ➞Span = 100 ➞0%
3.
View mA output values in the Auxiliary Reading display.
level space or distance
Empty ➞Span = 4 ➞20mA Empty ➞Span = 20 ➞4mA
4.
View the Failsafe Time Left in % (before "LOE" is displayed).
If the value reaches 0, the "old" Reading, Bar Graph, relays,
and mA outputs are "held" and "LOE" flashes.
When a valid measurement is made, the value resets to 100.
The AIRANGER DPL PLUS advances to the "new" level;
operating displays and outputs accordingly.
RUN MODE DISPLAY FUNCTIONS
1Transducer 9Emptying
2Point Number 10 Data Out
3Reading 11 Point Scanned
4Filling 12 Auxiliary Reading
5Percent 13 Relay #4 energized
6Hi Alarm 14 Relay #3 de-energized
7Bar Graph 15 Normal Operation
8Lo Alarm 16 Failsafe Operation
RUN MODE KEYPAD FUNCTIONS
PERFORMANCE EVALUATION
Monitor system performance, under all operating conditions.
If alternate display, relay, or mA output operation is required,
or "LOE" is displayed, see instruction manual PL-421.
Connect (or enable) alarm/control equipment only after
satisfactory performance is verified.
PL-431
September 1995
%
100
0
%
1234
DUAL POINT LEVEL MONITOR
QUICK START GUIDE
0
100
%
1234
%
to enter the RUN mode
Display Distance in 12 .
Display next Point Number (scroll display stopped).
Initiate program mode access ( see ).
Display previous Point Number (scroll display stopped).
Display Empty / Fill Rate in 12 .
Display Failsafe Time Left in 12 .
Display temperature in 12 .
%
Display mA output in 12 .
Key in Parameter # to display value in 12 .
Display Material Level in 12 .
Stop / Start scroll display.
ACCURATE, RELIABLE
LIQUID and SOLID LEVEL MEASUREMENT
with
CUSTOM GRAPHIC LCD,
VOLUME CONVERSION,
ANALOG mA OUTPUTS,
ALARM RELAYS,
& BIC-II SUPPORT
33454310
PRR 2.3
%
Display Units / % in 3 (complete program mode access).
Transducer # Alarm Relay #
1Hi1
1Lo2
2Hi3
2Lo4
5 6 1
GENERAL
Quick Start details the minimum recommended start up
procedure for most AIRANGER DPL PLUS installations.
Refer to the individual product instruction manuals for
complete installation and interconnection instructions for the:
AIRANGER DPL PLUS
Ultrasonic Transducers
TS-3 Temperature Sensors (if used)
BIC-II Buffered Interface Converter (if used)
To measure distances greater than 60 m (200ft), refer to the
AIRANGER DPL PLUS manual (PL-421).
Ensure all process control equipment is disabled until
satisfactory AIRANGER DPL PLUS performance is verified.
INITIAL START UP
1. Place the programmer in the AIRANGER DPL PLUS
enclosure lid recess. The magnetic programmer base
holds it in place.
2. Apply power to the AIRANGER DPL PLUS,
OFF is displayed.
3.
During the following procedure:
a) If the selection desired is already displayed...
no entry is required. (Advance to the next step.)
b) If an entry error is made...
and try again.
VESSEL # 1
STEP 1 Which type of Operation is desired?
(P001)
0 = off (point out of service)
1 = level (how full the vessel is)
2 = space (how empty the vessel is)
3 = distance (from the transducer face)
e.g. for level
to advance
STEP 2 Which Material is being monitored?
(P002)
1 = liquid (flat level surface)
2 = solid (uneven sloped surface)
e.g. for liquid
to advance
STEP 3 Which Measurement Response is desired?
(P003)
1 = slow (0.1 m/min)
2 = medium (1 m/min)
3 = fast (10 m/min)
(Slower response improves measurement stability!)
e.g. for fast
to advance
STEP 4 Which Transducer is connected (check nameplate)?
(P004)
ULTRASONIC ULTRASONIC/TEMPERATURE
0 = not entered 100 = ST-H 106 = XPS-40
1 = ST-25 101 = XCT-8 107 = XLT-30
2 = ST-50 102 = XPS-10 108 = XLT-60
3 = ST-100 103 = XCT-12 109 = XLS-30
4 = LR-21 104 = XPS-15 110 = XLS-60
5 = LR-13 105 = XPS-30 111 =XKS-6
e.g. for LR-21
to advance
STEP 5 Which measurement Units are desired?
(P005)
1 = metres (m) 4 = feet (ft)
2 = centimetres (cm) 5 = inches (in)
3 = millimetres (mm)
e.g. for feet
to advance
STEP 6 Where is Empty (transducer face to vessel bottom)?
(P006)
(Presets Span to the maximum recommended value).
0.000 to 9999
e.g. for 60 Units
to advance
STEP 7 What is the Span (Empty to highest material level)?
(P007)
0.000 to 9999
e.g.
To monitor 1 vessel, proceed to OPERATION.
VESSEL # 2
a.
b.
c. Repeat STEP 1 to 7
(Use the same STEP 5 value as for Vessel # 1).
To monitor 2 vessels, proceed to OPERATION.
DIFFERENCE or AVERAGE DISPLAYS
To display the difference or average of 2 vessels...
a.
b.
c. (difference) or (average) and .
112 = XRS-5
(return to STEP 1)
1234
%
to enter the program mode
and display . . .
1234
1234
1234
1234
1234
1234
1234
1234
(switch to next vessel)
1234 1234
or
Proceed to OPERATION.
432