Milwaukee SM500 User manual

Other Milwaukee Measuring Instrument manuals

Milwaukee MI 404 User manual

Milwaukee

Milwaukee MI 404 User manual

Milwaukee MW10 User manual

Milwaukee

Milwaukee MW10 User manual

Milwaukee M12 SUB-SCANNER 2291-20 User manual

Milwaukee

Milwaukee M12 SUB-SCANNER 2291-20 User manual

Milwaukee 2217-40 User manual

Milwaukee

Milwaukee 2217-40 User manual

Milwaukee MA886 User manual

Milwaukee

Milwaukee MA886 User manual

Milwaukee pH600 User manual

Milwaukee

Milwaukee pH600 User manual

Milwaukee PRO Lux MW700 User manual

Milwaukee

Milwaukee PRO Lux MW700 User manual

Milwaukee SM700 User manual

Milwaukee

Milwaukee SM700 User manual

Milwaukee M12 CLLP-301C User manual

Milwaukee

Milwaukee M12 CLLP-301C User manual

Milwaukee MI415 User manual

Milwaukee

Milwaukee MI415 User manual

Milwaukee CALIBRATION 2238-20 User manual

Milwaukee

Milwaukee CALIBRATION 2238-20 User manual

Milwaukee MI805 User manual

Milwaukee

Milwaukee MI805 User manual

Milwaukee MW102 User manual

Milwaukee

Milwaukee MW102 User manual

Milwaukee M12 SPL User manual

Milwaukee

Milwaukee M12 SPL User manual

Milwaukee MC310 User manual

Milwaukee

Milwaukee MC310 User manual

Milwaukee 3712 User manual

Milwaukee

Milwaukee 3712 User manual

Milwaukee CALIBRATION 2238-20 Operating instructions

Milwaukee

Milwaukee CALIBRATION 2238-20 Operating instructions

Milwaukee LDM 80 User manual

Milwaukee

Milwaukee LDM 80 User manual

Milwaukee LDM 45 User manual

Milwaukee

Milwaukee LDM 45 User manual

Milwaukee MAX MW160 User manual

Milwaukee

Milwaukee MAX MW160 User manual

Milwaukee MW100 User manual

Milwaukee

Milwaukee MW100 User manual

Milwaukee M12 3622-20 User manual

Milwaukee

Milwaukee M12 3622-20 User manual

Milwaukee REDSTICK MLDIG14 User manual

Milwaukee

Milwaukee REDSTICK MLDIG14 User manual

Milwaukee MI412 User manual

Milwaukee

Milwaukee MI412 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Milwaukee
USER MANUAL
PORTABLE
ORP METER
MODEL: SM500
Smart ORP Meter
ISMIL500 11/01
SPECIFICATIONS:
SM500
RANGE ±1000 mV
RESOLUTION 1 mV
ACCURACY (@25°C) ±5 mV
ORP ELECTRODE MA921B/1 (included)
ENVIRONMENT 0 to 50°C, 95% RH max.
BATTERY TYPE 9V alkaline (included)
BATTERY LIFE approximately 300 hours of use
DIMENSIONS 145 x 80 x 40 mm
WEIGHT 220 g (with battery) meter only
OPTIONAL ACCESSORIES:
M10000B Electrode rinse solution, 20 ml sachet (25 pcs)
MA9015 Electrode storage solution, 220 ml bottle
MA9020 200-275 mV ORP solution, 220 ml bottle
MA921B/1 Platinum ORP electrode with 1 m cable
WARRANTY:
This instrument is warranted from all defects in materials and
manufacturing for a period of two years from the date of purchase.
The electrode is warranted for a period of 6 months.
If during this period, the repair or replacement of parts is required,
where the damage is not due to negligence or erroneous operation
by the user, please return the parts to either dealer or our office
and the repair will be effected free of charge.
Note: We reserve the right to modify the design, construction and
appearance of our products without advance notice.
Milwaukee
OPERATION:
• The meter is supplied complete with a 9V battery. Slide off
the battery compartment cover on the back of the meter.
Install the battery while paying attention to its polarity.
• Always remove the electrode protective cap before taking
any measurement. If the electrode has been left dry, soak
the tip in storage solution for a few
minutes to reactivate it.
• Connect the ORP electrode to the
BNC socket on the top of the meter.
• Immerse the tip (2.5 cm) of the ORP
electrode into the sample.
• Turn the instrument on by pressing
the ON/OFF key.
• Allow the reading to stabilize before
taking measurements.
• After use, switch the meter off and
store the electrode with a few drops
of storage solution in the protective
cap.
• The meter is factory calibrated. ORP
electrodes are inter-changeable and
no mV calibration is needed when
they are replaced.
MAINTENANCE:
• To correctly perfom a redox measurement, the surface of
the ORP electrode must always be clean. Use for this
purpose the M10000B rinse solution. If needed, brush the
Platinum tip with very fine abrasive paper.
• When not in use, the tip of the electrode should always be
kept moist and safe from any mechanical stress.
BATTERY REPLACEMENT:
When the battery becomes weak the meter will display "S".
When the low battery indicator appears, the battery has only
about 50 hours of working time left. A low battery will result in
unreliable measurements. It is recommended to replace the
battery immediately.
Battery replacement must only take place in a non hazardous
area using an alkaline 9V battery.
Turn the meter off, slide off the battery compartment cover at
the rear of the meter and replace the 9V battery with a new
one. Make sure the battery contacts are tight and secure, seat
the battery in its compartment and insert the cover again.