Milwaukee MI415 User manual

Other Milwaukee Measuring Instrument manuals

Milwaukee T75 User manual

Milwaukee

Milwaukee T75 User manual

Milwaukee 2235-40 User manual

Milwaukee

Milwaukee 2235-40 User manual

Milwaukee MW180 MAX User manual

Milwaukee

Milwaukee MW180 MAX User manual

Milwaukee ORP 57 User manual

Milwaukee

Milwaukee ORP 57 User manual

Milwaukee MI 405 User manual

Milwaukee

Milwaukee MI 405 User manual

Milwaukee Mi 150 User manual

Milwaukee

Milwaukee Mi 150 User manual

Milwaukee PRO Lux MW700 User manual

Milwaukee

Milwaukee PRO Lux MW700 User manual

Milwaukee PRO MI414 User manual

Milwaukee

Milwaukee PRO MI414 User manual

Milwaukee MW13 User manual

Milwaukee

Milwaukee MW13 User manual

Milwaukee REDLITHIUM User manual

Milwaukee

Milwaukee REDLITHIUM User manual

Milwaukee MA871 User manual

Milwaukee

Milwaukee MA871 User manual

Milwaukee MW102 User manual

Milwaukee

Milwaukee MW102 User manual

Milwaukee 2236-20 User manual

Milwaukee

Milwaukee 2236-20 User manual

Milwaukee M12 3PLA User manual

Milwaukee

Milwaukee M12 3PLA User manual

Milwaukee MI806 User manual

Milwaukee

Milwaukee MI806 User manual

Milwaukee MW101 User manual

Milwaukee

Milwaukee MW101 User manual

Milwaukee MW13 User manual

Milwaukee

Milwaukee MW13 User manual

Milwaukee MI490 User manual

Milwaukee

Milwaukee MI490 User manual

Milwaukee SM801 User manual

Milwaukee

Milwaukee SM801 User manual

Milwaukee Mi170 User manual

Milwaukee

Milwaukee Mi170 User manual

Milwaukee SM700 User manual

Milwaukee

Milwaukee SM700 User manual

Milwaukee M12 3622-20 User manual

Milwaukee

Milwaukee M12 3622-20 User manual

Milwaukee Mi453 User manual

Milwaukee

Milwaukee Mi453 User manual

Milwaukee HEAVY DUTY 7,5 m LED Tape Measure User manual

Milwaukee

Milwaukee HEAVY DUTY 7,5 m LED Tape Measure User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER MANUAL
MI415
PRO Turbidity Meter
milwaukeeinstruments.com (USA & CAN)
milwaukeeinst.com
BATTERY REPLACEMENT
Battery replacement must only take place in a non-
hazardous environment.
Simply rotate the battery cover on the back of the meter.
Detach the battery from the terminals and attach a fresh
9V battery while paying attention to the correct polarity.
Insert the battery and replace the cover.
ACCESSORIES
MI0004 Tissue for wipping cuvets (4 pcs)
MI0005 9V battery (1 pc)
MI0011 10 mL glass cuvete (2 pcs.)
MI0012 Cap for 10 mL glass cuvet (2 pcs.)
MI0013 Stopper for 10 mL glass cuvet (2 pcs.)
MI515-100 Calibration standards: 0, 10, 500 FNU (3 x
30 mL dropper bottles)
CERTIFICATION
Milwaukee Instruments conform to the CE
European Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product as
household waste. Hand it over to the
appropriate collection point for the recycling of electrical
and electronic equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them
with other household waste. Hand them
over to the appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents potential negative consequences for human
health and the environment. For detailed information,
contact your local household waste disposal service or
go to www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely suitable
for your specific application and for the environment in
which it is used. Any modification introduced by the user
to the supplied equipment may compromise the meter’s
performance. For your and the meter’s safety do not use
or store the meter in hazardous environment. To avoid
damage or burn, do not perform any measurement in
microwave ovens.
WARRANTY
These instruments are warranted against defects in
materials and manufacturing for a period of 2years from
the date of purchase. This warranty is limited to repair or
free of charge replacement if the instrument cannot be
repaired. Damage due to accidents, misuse, tampering
or lack of prescribed maintenance is not covered by
warranty. If service is required, contact your local
Milwaukee Instruments Technical Service. If the repair is
not covered by the warranty, you will be notified of the
charges incurred. When shipping any meter, make sure it
is properly packaged for complete protection.
ISTMI415 07/20
SATISFACTION
GUARANTEED
MI415 PRO Turbidity Meter
Dear Customer,
Thank you for choosing a Milwaukee Instruments
product. This manual will provide you with the necessary
information for the correct use of the instrument. Please
read it carefully before using the meter.
SPECIFICATIONS
Range 0.00 to 50.00 FNU
50 to 1000 FNU
Resolution 0.01 FNU and 1 FNU
Precision ±0.5FNU or ±5% of reading, whichever
is greater
Light Source High emission infrared LED
Light Detector Silicon Photocell
Method Detection of scattered light, according
to ISO 7027
Environment 0 to 50 °C (32 to 122 °F)
100% RH max
Battery Type 1 x 9 volt
Auto-Shut o After 5’ of non-use
Dimensions 192 x 104 x 52 mm
(7.5 x 4.1 x 2”)
Weight 380 g
MEASUREMENT PROCEDURE
1. Turn the meter on by pressing ON/OFF.
2. When the LCD displays “- - -”, the
meter is ready.
3. Fill a clean, dry cuvet with sample up
to the mark.
4. Replace the cap.
5. Clean the cuvet with a lintfree cloth
to remove any fingerprints, dirt or
waterspots.
6. Place the cuvet into the holder and
ensure that the notch on the cap is
positioned securely into the groove.
7. Press READ/▲ and “SIP” will blink
during measurement.
8. The instrument directly displays turbidity in FNU units.
CALIBRATION PROCEDURE
1. Turn the meter on by pressing ON/OFF. When the LCD
displays “- - -”, the meter is ready.
2. Press CAL key and “CAL” will blink on the display.
3. Press CAL key again. The date of calibration in MM.DD
format appears on the LCD.
4. To toggle between month and day
press DATE/▶ key.
5. To change the date press READ/▲
key.
6. To confirm the date values press CAL
key.
A blinking ZERO message will appear on the LCD.
Insert the 0 FNU standard and press CAL key. “SIP”
will blink during measurement.
▶ ▶
7. At the end the blinking “10.00” message will appear
on the LCD.
Insert the 10 FNU standard and press CAL key. “SIP”
will blink during measurement.
▶ ▶
8. The blinking “500” message will appear on the LCD.
Note: At this moment you can exit calibration by
pressing READ/ key and the meter will memorize only
the two-point calibration.
Insert the 500 FNU standard and press CAL key. “SIP”
will blink during measurement
▶ ▶
9. At the end of the reading the instrument goes directly
to measurement mode. Now the instrument is
calibrated and ready to use.
Note: A monthly calibration is recommended.
The instrument can be checked with the supplied
standard solutions each day.
To check the date of the last calibration simply press
DATE/▶ key.
GUIDE TO DISPLAY CODES
This prompt appears for 1 second each
time the instrument is turned on.
The dashes “- - -” indicates that
the meter is in a ready state and
measurement can be performed.
Sampling In Progress. Flashing “SIP”
prompt appears each time the meter
is performing a measurement.
The presence of battery icon on the
display indicates that the battery
voltage is getting low and the battery
needs to be replaced.
“-BA-”, the battery is dead and must
be replaced. Once this indication is
displayed, the meter will lock up. Change
the battery and restart the meter.
“CAL”, the meter is in calibration mode.
If the CAL key is not pressed within 6
seconds, the meter will automatically
switch to idle mode.
“CL” appears on the lower part
of the display when the meter
is in calibration mode.