manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Milwaukee
  6. •
  7. Measuring Instrument
  8. •
  9. Milwaukee MW100 User manual

Milwaukee MW100 User manual

Other Milwaukee Measuring Instrument manuals

Milwaukee CALIBRATION 2238-20 User manual

Milwaukee

Milwaukee CALIBRATION 2238-20 User manual

Milwaukee PH55 User manual

Milwaukee

Milwaukee PH55 User manual

Milwaukee T75 User manual

Milwaukee

Milwaukee T75 User manual

Milwaukee 3631-20 User manual

Milwaukee

Milwaukee 3631-20 User manual

Milwaukee REDSTICK MLDIG14 User manual

Milwaukee

Milwaukee REDSTICK MLDIG14 User manual

Milwaukee HEAVY DUTY 7,5 m LED Tape Measure User manual

Milwaukee

Milwaukee HEAVY DUTY 7,5 m LED Tape Measure User manual

Milwaukee MW12 User manual

Milwaukee

Milwaukee MW12 User manual

Milwaukee 2235-40 User manual

Milwaukee

Milwaukee 2235-40 User manual

Milwaukee PH55 User manual

Milwaukee

Milwaukee PH55 User manual

Milwaukee MW802 User manual

Milwaukee

Milwaukee MW802 User manual

Milwaukee M12 CLLP-301C User manual

Milwaukee

Milwaukee M12 CLLP-301C User manual

Milwaukee PST MW100 PRO User manual

Milwaukee

Milwaukee PST MW100 PRO User manual

Milwaukee MW180 MAX User manual

Milwaukee

Milwaukee MW180 MAX User manual

Milwaukee 48-22-5112 User manual

Milwaukee

Milwaukee 48-22-5112 User manual

Milwaukee MC310 User manual

Milwaukee

Milwaukee MC310 User manual

Milwaukee MC510 User manual

Milwaukee

Milwaukee MC510 User manual

Milwaukee SM801 User manual

Milwaukee

Milwaukee SM801 User manual

Milwaukee Mi170 User manual

Milwaukee

Milwaukee Mi170 User manual

Milwaukee MW301 User manual

Milwaukee

Milwaukee MW301 User manual

Milwaukee MI407 User manual

Milwaukee

Milwaukee MI407 User manual

Milwaukee MW102 User manual

Milwaukee

Milwaukee MW102 User manual

Milwaukee C65 User manual

Milwaukee

Milwaukee C65 User manual

Milwaukee MI 106 User manual

Milwaukee

Milwaukee MI 106 User manual

Milwaukee REDLITHIUM User manual

Milwaukee

Milwaukee REDLITHIUM User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SPECIFICATIONS:
MW100
RANGE 0.0 to 14.0 pH
RESOLUTION 0.1 pH
ACCURACY (@25°C) ±0.2 pH
TYPICAL EMC DEVIATION ±0.1 pH
pH ELECTRODE SE220 (included)
ENVIRONMENT 0 to 50°C, 95% RH max.
BATTERY TYPE 1 x 9V alkaline (included)
BATTERY LIFE approximately 300 hours of use
DIMENSIONS 143 x 80 x 32 mm
WEIGHT 220 g (with battery) meter only
OPTIONAL ACCESSORIES:
M10004B pH 4.01 buffer solution, 20 mL sachet (25 pcs)
M10007B pH 7.01 buffer solution, 20 mL sachet (25 pcs)
M10010B pH 10.01 buffer solution, 20 mL sachet (25 pcs)
M10000B Electrode rinse solution, 20 mL sachet (25 pcs)
MA9015 Electrode storage solution, 220 mL bottle
SE220 pH electrode with BNC connector and 1 m cable
MA950 Portable meter wall mounting kit
WARRANTY:
This instrument is warranted from all defects in materials and
manufacturing for a period of two years from the date of purchase.
The electrode is warranted for a period of six months.
If during this period, the repair or replacement of parts is required,
where the damage is not due to negligence or erroneous operation by
the user, please return the parts to either dealer or our office and the
repair will be effected free of charge.
Note: We reserve the right to modify the design, construction and
appearance of our products without advance notice.
USER MANUAL
PORTABLE
pH METER
MODEL: MW100
OPERATION:
• The meter is supplied complete with a
9V battery. Slide off the battery
compartment cover on the back of the
meter. Install the battery into the battery
clip connector while observing polarity.
• Always remove the electrode
protective cap before taking any
measurement. If the electrode has been
left dry, soak the tip (bottom 2.5 cm) in
rinse solution (M10000B) for a few
minutes to reactivate it.
• Connect the pH electrode to the BNC socket on the top of
the meter.
• Make sure that the meter has been calibrated before taking
any measurements (see Calibration Procedure).
• Immerse the tip (2.5 cm) of the pH electrode into the sample.
• Turn the instrument on by pressing the ON/OFF key.
• Allow the reading to stabilize before taking measurements.
• After measurements, switch the meter off and store the
electrode with a few drops of storage solution
(MA9015) in the protective cap.
CALIBRATION PROCEDURE:
• Remove the protective cap from the electrode.
• Rinse tip off with distilled water or a small
quantity of pH 7.
• Immerse the electrode tip into a new sachet
of pH7 calibration solution and allow the reading
to stabilize.
• Adjust the pH7 (OFFSET) calibration trimmer to
display "7.0 pH".
• Open a new sachet of pH4 calibration solution
and use a small quantity to rinse the electrode.
• Immerse the electrode tip inside the pH4 sachet
and allow the reading to stabilize.
• Adjust the pH4/pH10 (SLOPE) calibration
trimmer to read "4.0 pH".
• The calibration is now complete and the
meter is ready to take measurements.
• It is suggested the meter be calibrated at least
once a month, after a prolonged period of
inactivity, and after electrode replacement.
BATTERY REPLACEMENT:
When the battery becomes weak the meter
will display " ".
When the low battery indicator appears, the
battery has only about 50 hours of working
time left. A low battery will result in
unreliable measurements.
Prompt battery replacement is required.
Battery replacement must only take place in
a non-hazardous area using an alkaline 9V
battery.
Turn the meter off, slide the battery
compartment cover located at the rear of the
meter off and replace the 9V battery with a
new one. Make sure the battery contacts are fully engaged in
the connector, seat the battery in its compartment and replace
the cover.