MISUMI MTCTR User manual

DIGITAL TEMPERATURE CONTROLLER

- 1 -
*Thank you for purchasing Digital Temperature Controller. Please go through this Instruction Manual carefully
and use the unit in proper manner.
NOTICE/WARNING BEFORE OPERATION USE
The following symbol is provided to prevent incident or damage. Kindly refer to the details of the
WARNING/CAUTION when using for the first time.
● Make sure the correct wiring connection before turning on electricity.
Miss-Wiring may cause malfunction of the unit and fire.
● Never modify the unit to prevent damage or incident such as malfunction and fire etc.
● For prevention of its malfunction, do not push the front key with sharp points.
● Spare terminal must not be used for other purposes.
・Please put this user's manual aside for your reference, when operating the unit.
・Copy or reprint of this manual, wholly or partially, is not allowed.
・The contents of this manual may change without notice in future.
OPERATING ENVIRONMENT
Neveruseinthefollowingenvironments. It may cause fire and break the wire.
1)Around explosive gases, inflammable gases or corrosive gases
2)In either sunshine or ambient temperature (above 50℃) remarkably increases
3)In very low ambient temperature (below 0℃), such as outdoors in cold areas
4)In very high humidity (85%RH or higher)
5)Around splashing of water or chemicals
6)Under severe vibration or shocks
7)Around dust, iron powder, black smoke
8)Around external noise, induction trouble, vibration, large shocks, and others such that can have damaging
effects to the electric circuit.
9)Under violent temperature change
SPECIFICATIONS
Type MTCTR:RelaycontactMTCTS:SSR drive voltage
Power Supply Voltage
100 to 240V AC, 50/60Hz
Power Consumption Below 10 VA
Memory Element EEPROM
Input of Sensor Thermocouple,R.T.D./0-5V,1-5V,4-20mA (Changeable by front key)
Control Output Relay contact, SSR drive voltage, Current
Control Method Two kinds of PID,ON/OFF
Operation
Environment 0 to 50℃,20 to 90%RH(Avoid making dew)
Storage Environment -25 to 70℃,5 to 95%RH(Avoid making dew)
Weight Less than 180g
Location of the Unit
Setting Keep away from the followings.
・Gas of corrosion, dust and oily smoke. ・The electric noise of generator
・The influence of electromagnetic field.・Mechanical vibration and shock.
・The direct sunlight.
Installation condition Installation category Ⅱ
DIGITAL TEMPERATURE CONTROLLER USER'S MANUAL2007.3(The 1st edition)
Due to mishandling, serious dangers may occur to the operator such as death,
electrocution and a skin burn.
WARNING
CAUTION
Due to mishandling, it may cause some damage to the unit or the operator
getting slight injury.
WARNING
CAUTION

- 2 -
CAUTION BEFORE CONTROL
・Set-upprogramisstoredoperation, as non-volatile memory, is equipped with the controllers.
・Either thermocouple or R.T.D.(Pt 100/JPt100) is selectable input type, but Current/Voltage input needs to be
selected individually. For suitable application, please select most appropriate input type and adjust input setup.
(※Thermocouple at the time of shipment (K) )
・PID or ON/OFF control is selective for the optimal perform and each detail of features is specified in the table
below.
※PID constants are automatically calculated and written in, when control begins or SV is altered on self-tuning.
PID Control ON/OFF Control
Merit Better control result is achieved as
opposed to that of ON/OFF control. Life span of relay is generally longer, as it is ON when SV and
it is OFF when temperature is over SV (For heating control).
Demerit
Life span of relay is shorter, as output
exists frequently with relay contact. Control value is worse in comparison with that of PID control.
PARTS INDICATION
PV Processvalue,characterforsetting
modedisplay.
SV Settingvalue,inputvalueforsetting
modedisplay.
OUT1
LightsONwhenoutput1turnON
OUT2
LightsONwhenoutput2turnON
AL1 LightsONwhenEventoutput1turnON
AL2 LightsONwhenEventoutput2turnON
COM
FlashONandOFFwhencommunicating.
LightsONwhencommunicationis
selectedasanoption.
RDY LightsONunderReady
DI LightsONwhenDIturnON
MODEKEY
Forchangeofdisplay
FUNCKEY Foractionoffunctionsetting
▲▼KEY Updownkeyforchangeofsettingvalue.
Holdingtheupdownkeysarethevalueata
rapidrate.
※ partisnotused.
INSTALLTIONANDWIRING
1)OuterDimensions
2)PanelCutout
(48×No.ofunits−3)
48
60 2 77
59
Attachment
Case (black)
Packing
48
Front
A
60 or more
A A
A:45mm tolerance:+0.6 -0

- 3 -
3)Wiring
CAUTION
For prevention of electric shock, please connect wiring only
after turning power off and don’t touch the terminal part
when powered on.
PRECAUTIONS ON WIRE CONNECTION
1) Whenconnecting wires, be sure to turn off the power supply in advance, or electric shock may result.
2) This unit will not perform control operation for approx. 4 seconds after turning on the power. Note this point
when using the unit as an interlock circuit, because no output is issued during this period.
3) Use the crimping terminal for wire connection that fits M3.5 thread.
(Tighten the wire directly at the center portion)
4) Use wire with line resistance 5Ωor lower (per line) for connection between the temperature measuring
resistor and the temperature controller, and use the specified compensation copper wire or strand itself for
connection between the thermocouple and temperature controller.
5) When using the unit in the vicinity of a noise source, use shielded wire. Do not lay input and output lines
together in the same duct or conduit tube.
6) Separate the input and output signal lines 50 cm or more from the power supply line and load line.
① ⑥ ⑪
② ⑦ ⑫
③ ⑧ ⑬
④ ⑨ ⑭
⑤ ⑩ ⑮
OUT1
Relay output②
250V AC, 3A
(Loadresistance) ③
SSR drive voltage
+②
12VDC output −③
POWER ON
100V to 240V AC 50/60Hz 10VA ④
(NOpolarity)
AC100V〜240V 50〜60Hz 10VA ⑤
EV2(Foralarm)
①⑥
Relayoutput250V AC2.4A(Load resistance)
EV1 (For alarm)
⑪ Relayoutput
250VAC,2.4A
⑫(Loadresistance)
SensorInput
⑬bB⑬−
⑭B⑭+
⑮A
RTD TC

- 4 -
SET-UP PARAMETERS BEFORE USAGE
・Follow the instructions below to set-up parameters
*If advanced set-up is required, refer to “Operation Flow and Setting”screen.
ParameterNo
1
Referto[Table1.Input Sensor Selection/Setting Range] and set to the input
settings of the sensor you are using (Refer to Default settings) SET1 2.
Input type setting
↓
2
Set Yes/No of decimal requirements. (Refer to Default settings) SET1 6.
Position of decimal point
↓
3
Refer to “Caution before Flow”and set the control alternatives available for
Output 1.
Recommended settings
Main Unit: SSR outputPID Control
Main Unit: Relay contact output ON-OFF control(Refer to Default settings)
SET2 13.
Selection of control type
setting
↓
4
Set according to Heating control (0:Reverse) or -Cooling Control(1:Normal)
(Refer to Default settings) SET2 14.
Change of normal or
reverse
↓
5
If alarm output is required, set Upper and Lower limit setting values. Refer to
“Alarm Operating Range”table shown on P5.
The Alarm Operating Range compares the measured value and present value
to turn the event on or off. It is effective for monitoring abnormalities or
starting/stopping of other systems.
SET3 38./SET4 48.
Function setting for EV 1
Function setting for EV 2
(Refer to Ex.5.)
↓
6
Set SV Operate mode display
Primary displays
↓
7
Set AT(Auto Tuning) *When using PID control
Default values are pre-set for PID. Default values can be used, but in order to
stabilize controls, please perform AT.
AT Calculations depend on the kind of control.
Select 1, and press FUNC key to startAT.
Press the FUNC key once more during operation to stop.(Refer to Default
settings)
SET2 16
Setting for PID tuning
type
↓
8
Other
Check each movement. (Stable temperature/Alarm)
Setting of mis-operation(SV limiter/ Keylock)
Table1.To select input sensors and setting range. (unit:℃)
Symbol Low limit〜High limit 0.0Setting
00: K Thermocouple -200〜1372 -199.9〜990.0
01: J 〃-200〜850 -199.9〜850.0
02: R 〃0〜1700 −
03: T 〃 -200〜400 -199.9〜390.0
04: N 〃 -200〜1300 -199.9〜990.0
05: S 〃 0〜1700 −
06: B 〃 0〜1800 −
10: Rt100 -199〜500 -199.9〜500.0
11: JPt100 -199〜500 -199.9〜500.0
Setting of shipment
SET1 2. Input type setting 00:KThermocouple
SET16.Position of decimal point 0:Not required
SET2 14. Change of normal or reverse 0:Reverse
SET338./SET4 48.
Function setting for EV 1 00:None
Function setting for EV 2 00:None
SET2 16
Setting for PID tuning type 1:Auto-tuning output 1

- 5 -
ALARM OPERATING RANGE
Deviation
highandlow
limit
AL1L AL1H
△
Absolutevalue
high and low
limit
AL1H
AL1L
0
Deviation
highlimit AL1H
△
Absolutevalue
highlimit AL1H
0
Deviation
lowlimit AL1L
△
Absolute value
lowlimit AL1L
0
Deviation
highandlow
limit range
AL1L AL1H
△
Absolutevalue
high and low
limit range
AL1H
AL1L
0
△:Position of Setting value AL1L:Lower limit setting value AL1H:Upper limit setting value
:EventONarea
*Theabove alarm settings (AL1L, AL1H) apply for when positive values are set.
1. Power ON
Automatically
2. Initial Display
Automatically
3. Operation Mode
Press MODE Key (10sec)
4. Immediately after the "Blink",
press FUNC Key, and quickly
press MODE Key.
5. Press MODE Key (3 sec)
6. Press UPKey(△)for 1 →7
7. Press FUNC Key
8. Power OFF
9. Power ON
10. Initial Display
Automatically
11. TIMER Setting Mode
(OPERATION Mode)
12. Press UP Key (△)
for 1 →7
13. Go on TIMER Setting
Press
MODE Key consecutively
_ I n P
00
Processvalue
Settingvalue
SE t 7
oFF
S E t
1
_ C k F
oC
●HowtoreleaseBLINDFunction
_ C k F
oC
_ S u 1
on
SE t 1
on
taking4sec
(Blink once)
SE t 7
on
Processvalue
Settingvalue
taking 4 sec
**1 Please select an appropriate character
(eg. Timer Setting etc) being of BLIND
Function effect for the demanding release.
**2 Character selected for TIMER Setting.
**3 BLIND Function for "SELECTION
DISPLAY (Timer Setting Mode)" is released.
**1
**2
**3
_ I n P
00
S E t
1
S E t
7

- 6 -
OPERATION FLOW AND SETTING MENU
MODE key
MODE key, return to A
●Operate mode display
●Power ON
Shows for 4 seconds
(Warming up)
A. Primarydisplays
Process value PV Set the temperature
Setting value SV required
B. Priority displays. Refer to Ex.1.
SET0: Priority displays by setting and
shows max.9 displays by setting.
●FUNC key
FUNK key operates on the
selected setting mode 7. Refer
to Ex.2.
Ex.1. Priority displays & its setting
This function is to shift the most essential screens on
setting mode into operation mode as a priority. Please
select priority displays through priority display setting.
eg:
*Screenisshiftedwhenpressing mode key each time.
Ex.2. FUNC key work
This function is to enable FUNC key to use as a specific
key, for the following actions selected in FUNC key setting
belonged to setting mode.
1. Digit shift
Setting digit shift is enabled when setting value is
changed.
2. RUN/READY
Control stop (READY) and control performance (RUN) are
alternately switched every FUNC key is pressed. (READY
lamp is ON during control stop)
3. Auto-Tuning (AT)
AT starts instantly after pressing FUNC key. (Start/Reset
operation is available, each time FUNC key is pressed)
4. Timer
Available for start/reset.
Press MODE key more
than 2 seconds
●Setting mode
Ex.3. To select PID
Feature of type A and B
Type A Ordinary PID
Type B Over shoot protection PID
If control is unstable under self-tuning, please
change to type Aor B and also to ON/OFF-control.
Ex.4. ARW
Anti-reset wind-up take effect for overshooting by
over-integral of PID control action.
・ARW controls integral action (PV accords with
SV).
・If integral value goes down, it takes effects.
If integral value is set "0", it stops integral
action.
Basic display
Output 1 manipulated value
Setting high limit for event Output 1

- 7 -
(Thenumericalvalueofdisplayisaninitialvalue.)
▲key ▲key
PV Initialsettingmode PV Controlsettingmode PV
SV Callingdisplay ▼key SV Callingdisplay ▼key SV
MODEkey MODEkey MODEkey
PV Selectinputtype PV PV
SV RefertoTable1. SV SV
MODEkey MODEkey
PV PV
SV SV
MODEkey MODEkey
PV PV
SV SV
MODEkey SV Controlperformance
SV Non-controlperformance
(Manipulatedvaluelowlimiteroutput)
PV SV Manualcontrol
SV MODEkey MODEkey
MODEkey PV
SV PV
PV SV SV
SV MODEkey
SV Notrequired PV
SV Required SV
MODEkey MODEkey
MODEkey
PV Selectablebelowfunctions PV
SV PV SV
SV None SV MODEkey
SV Changeofdigit SV 0:Reverse(Heating)
SV RUN/READY 1:Normal(Cooling) PV
SV Auto-Tuning MODEkey SV
SV Timer MODEkey
MODEkey PV
SV PV
PV SV
SV
SV None
SV Alllock(Notavailable)
SV Operationmodelockonly
SV Exceptoperationmode
MODEkey(returnto1)
MODEkey MODEkey
PV Tunessuitablysettingvalue PV PV
SV SV SV
SV Auto-tuningoutput1 MODEkey SV Normalopen
SV Self-tuningoutput1 SV Normalclose
SV Auto-tuningoutput2 PV MODEkey(returnto37)
SV Self-tuningoutput2 SV
SV Auto-tuningoutput1.2 MODEkey
PV
SV
MODEkey MODEkey(returnto9)
PV <WhenselectON/OFFControl>
SV PV
MODEkey SV MODEkey
PV
SV PV
SV
MODEkey MODEkey(returnto9)
PV
SV MODEkey
PV
SV MODEkey
PV
SV MODEkey
PV
SV MODEkey
PV
SV MODEkey(goto24.)
Forsettingofmanipulatedhighlimit
value.(output1)(%)
ForsettingOFFpositionof controloutput1.
Adiustscontrolsnsitivityof ON/OFFcontrol
foroutput1.
ForShifting proportionalband.
Forsettingofmanipulatedlowlimit
value.(output1)(%)
25.Lowlimitsettingofmanipulatedvalueforoutput1
Displayofhighlimitsettingof
settingvalue.
(WithinsettingrangeofTable1)
Displayoflowlimitsetting
ofsettingvalue.
(WithinsettingrangeofTable1)
Usableforcontrolmodesetting
Selectableandswitchablebelowcontrolmodes.
13.Selectionofcontroltypesetting
AdjustsARWby%0.0〜100.0(-
10.0〜110.0%)
34.OFFpositionsettingforoutput1
Adjustsproportionalbandfor
output1(%perSLL〜SLH)
Adjustsintegraltime
0〜3600(second)
Adjustsdeviativetime
0〜3600(second)
Adjustsproportionalcycletime1
〜120(second)
23.ARWsetting(seeEx.4)
EV1settingmodeCalling
display
Setsensitivitywhen
required(℃).
Setdelaytimerwhen
required(sec).
Foroutbreakofsensorand
heaterabnormal
38.FunctionsettingforEV1
39.HighlimitsettingforEV1
40.LowlimitsettingforEV1
41.ControlsensitivitysettingforEV1
Selectbelowfunctions.
Sethighlimitvalue.
Whenmeasurementvaluecomes
anerror,setthecorrection
value(Addition)
CRfiltereffectisoperationalon
softwarewhenmakingfirst-order
lagoperationtoprocess
value(PV)
Keylocksettingforprotectionof
erroroperation.
Selectablebelowfunctions
Thermocouple/R.T.D(Pt100,JPt100)
7.FUNKkeysetting(RefertoEx.2.)
5.Filterinput
6.Positionofdecimalpoint
<SET3:EventOutput1>
37.Eventoutput1Setting
<SET1:InitialSetting>
1.InitialSettingdisplay <SET2:ControlSetting>
9.InitialSettingdisplay
20.Integraltimesetting
16.SettingforPIDtuningtype
Auto-tuning:Selectabove1・3or5and
pressFUNCkeyonce.Calloffautotuning:
pressFUNCkeyonceonoperating.
44.PolaritysettingforEV1
Normalopen/closeisselectable
whileeventoutputisON.
33.Contorolsensitivitysettingforoutput1
31.Manualresetsetting
17.ATcoefficientsetting
18.ATsensitivitysetting
19.Proportionalbandsettingforoutput1
Coefficientismultipliedby
proportionalbandvaluecomputed
atauto-tuning.
Sensitivityissetupduring
ON/OFFcontrolatauto-
tuning,particularywhenPVis
fairlyunstable.
10.HighlimitsettinginSVlimiter
11.LowlimitsettinginSVlimiter
21.Deviativetimesetting
22.Proportionalcyclesettingforoutput1
8.Keylocksetting
3.PVcorrectiongain
4.ZeropointsettingforPVcorrection 12.Keylocksetting
2.Inputtypesetting
Whenmeasurementvaluecomes
anerror,setthecorrection
value(Multiplication)
Setlowlimitvalue.
14.Changeofnormalorreverse
15.Manipulatedvalueforoutput1(%)
42.DelaytimersettingforEV1
Switchablebelowcontroloutput
actions.
Showsprocessmanipulatedvalue
foroutput1,andsettingthevalue
onmanualcontrol.
Displayrange:0.0〜100.0%
(-10.0〜110.0%)
Settingrange:Manipulatedvalue
low/higelimiter
24.Highlimitsettingofmanipulatedvalueforoutput1
43.AbnormalforEV1
●Settingmode
SET
1
InP
00
SET
2
SET
3
PuG
1.00
PuS
1.00
PdF
1
dP
0
0
0.0
FU
0
0
1
2
3
4
LoC
0
0
1
2
3
SLH
1200
SLL
0
Md
run
run
rdy
Cnt
113
013
PID(RefertoEx.3.)
0:TypeA
1:TypeB
Controloutput1
1:PID
2:ON/OFF
Controloutput2
0:None
1:PID
2:ON/OFF
3:Eventoutput
dIr
0
rdy
Mu1
E1F
00
0:None
1:Deviationhighandlowlimit
2:Deviationhighlimit
3:Deviationlowlimit
4:Deviationhighandlowlimitrange
5:Absolutevaluehighandlowlimit
6:Absolutevaluehighlimit
7:Absolutevaluelowlimit
8:Absolutevaluehighandlowlimitrange
PVEventfunctions
0:None
1:EVoutputhold
2:Stand-bysequence
3:EVoutputhold&stand-bysequence
AdditionalEventfunctions
E1H
00
E1L
0
E1C
0
E1t
0
E1b
00
0:None
1:PVabnormal(sensorbreak)
2:Heaterabnormal
3:PV+Heaterabnormal
Type
0:None
1:Hold(Powerreset)
Action
E1P
0
0
1
tun
1
1
2
3
4
5
AtG
1.0
AtC
2.0
P1
3.0
I
0
d
0
t1
20
Arw
100.0
MH1
100.0
ML1
Pbb
C1
CP1
0

- 8 -
▲key ▲key ▲key
PV PV Timersettingmode PV
▼key SV ▼key SV Callingdisplay ▼key SV
MODEkey MODEkey MODEkey
PV PV PV
SV SV SV
SV Non-use MODEkey
SV Controloutput
SV Event1output PV
MODEkey SV MODEkey
PV
SV PV
SV Autostart (ONdelay) SV
SV Manualstart (ONdelay) MODEkey
SV Eventstart (ONdelay)
SV Autostart (OFFdelay) PV
SV Manualstart(OFFdelay) SV
MODEkey SV Eventstart(OFFdelay) MODEkey
SV SVstart(OFFdelay)
PV MODEkey PV
SV SV
MODEkey PV MODEkey
SV
PV SV Hour/minute PV
SV SV Minute/second SV
MODEkey MODEkey MODEkey
PV PV PV
SV SV SV
MODEkey MODEkey
PV PV
SV SV
MODEkey MODEkey
PV MODEkey PV
SV SV
PV MODEkey(returnto74)
SV
MODEkey
PV
SV
MODEkey MODEkey(returnto67)
PV
SV
SV Normalopen
SV Normalclose
MODEkey(returnto47)
Select9thdisplayon
operationmodeB.
Select5thdisplayon
operationmodeB.
Select6thdisplayon
operationmodeB.
Select7thdisplayon
operationmodeB.
Select8thdisplayon
operationmodeB.
Select1stdisplayon
operationmodeB.
Select2nddisplayon
operationmodeB.
Select3rddisplayon
operationmodeB.
Select4thdisplayon
operationmodeB.
75.Settingfor1stprioritydisplays
<SET7:Timer>
67.Timersetting
68.Timeroutputsetting
Selectprioritydisplays
Callingdisplay(RefertoEx.1.)
<SET4:EventOutput2>
47.Eventoutput2Setting <SET0:PriorityDisplays>
74.Prioritydisplayssetting
76.Settingfor2ndprioritydisplays
77.Settingfor3rdprioritydisplays
78.Settingfor4thprioritydisplays
79.Settingfor5thprioritydisplays
80.Settingfor6thprioritydisplays
82.Settingfor8thprioritydisplays
83.Settingfor9thprioritydisplays
81.Settingfor7thprioritydisplays
EV2settingmodeCalling
display
Selectbelowfunctions.
Sethighlimitvalue.
Setlowlimitvalue.
48.FunctionsettingforEV2
49.HighlimitsettingforEV2
50.LowlimitsettingforEV2
Normalopen/closeisselectable
whileeventoutputisON.
54.PolaritysettingforEV2
Thermocouple/R.T.D.(Pt100,J
Pt100)Input
Settingrange:0〜999
0.0〜999.9
Settingunit:℃
Setdelaytimerwhen
required(sec).
Foroutbreakofsensorand
heaterabnormal
71.TimerSVstartpermissiblerange
69.Timeroutputsetting
70.Timerunitselection
51.ControlsensitivitysettingforEV2
52.DelaytimersettingforEV2
53.AbnormalforEV2
Residualtimemonitor.
Timerstartwhenpressing
FUNCkey.
73.Timerresidualtimemonitorsetting
Current/VoltageInput
Settingrange:0〜9999
(Decimalpointat
designatedposition)
Settingunit:digit
Settingrange:0:00〜99:59
0:00〜59:59
72.Timertimesetting
Setsensitivitywhen
required(℃).
SET
4
SET
1
SET
E2F
00
E2H
00
E2L
00
E2C
0
E2t
0
E2b
00
E2P
0
0
1
SET
7
SET
tMn
0
0
1
2
tMF
1
1
2
3
4
5
6
7
HKn
1
1
2
tSu
0
t1n
0.00
t1A
0.00
SET
1
SET
0
SET
Pr11
Pr12
Pr13
Pr14
Pr15
Pr16
Pr17
Pr18
Pr19
0:None
1:Deviationhighandlowlimit
2:Deviationhighlimit
3:Deviationlowlimit
4:Deviationhighandlowlimitrange
5:Absolutevaluehighandlowlimit
6:Absolutevaluehighlimit
7:Absolutevaluelowlimit
8:Absolutevaluehighandlowlimitrange
PVEventfunctions
0:None
1:EVoutputhold
2:Stand-bysequence
3:EVoutputhold&stand-bysequence
AdditionalEventfunctions
0:None
1:PVabnormal(sensor
break)
2:Heaterabnormal
3
:
PV
+
Heaterabnormal
Type
0:None
1:Hold(Powerreset)
Action

- 9 -
(Display) (Description) (TroubleShooting)
L o C
−−−−
____
E r r 0
E r r 2
t I M E
At
S u 2
d I
F U n K
Shown whenever input value exceeds
the high limit of display range. Also
display when the wire thermocouple,
ABb-terminal of R.T.D is snapped off.
Check the snapping of thermocouple
and R.T.D. input.
Shown whenever input value exceeds
the low limit of display range. Check short circuit of input lines
between A-B and A-b R.T.D.
Display of memory error. In case this indication shows after
the re-input of power, replace unit if
it persists.
E r r 1
Display of A/D converter error or
incorrect sensor connection with
selectable input.
Ditto
Display of auto-tuning error.
Display when parameter is changed
in key-lock condition.
Check sensor connection or
change to other tuning.
Discontinue to change parameter.
Alternately this SV/PV display are
shown. Normality
Display when setting value is
changed on SV2 control.
Display when changing setting value
of shift on DI.
Discontinue to change setting value
(during control of SV2 )
Discontinue to change setting value
of the self on digital input
Display when making setting value
change in control display while
function key is on RUN/READY.
Display when altering setting value
in control display while being on
timer.
Discontinue to change setting value
Discontinue to change setting value
of the self on digital input

- 10 -
〜MEMO〜

- 11 -
Please contact your local MISUMI office or below
Phone : (81)120-343-603
MISUMI Corporation
This manual suits for next models
1
Table of contents
Popular Temperature Controllers manuals by other brands

Delta
Delta DTE10T Series instruction sheet

Thermo Solar
Thermo Solar SR14 Installation and operating instructions

Lily Tech
Lily Tech ZL-7850R manual

Water-Loo
Water-Loo ABM 300 Series Operating and maintenance instructions

Impact Subsea
Impact Subsea ISD4000 Installation & operation manual

Lake Shore
Lake Shore 325 user manual