12
2SHUDWLRQ)RU:LUHG5HPRWHFRQWUROOHU
3.6.3 Energy saving option
Energy saving option
Cursor
Setting display: SELECT
No occupancy energy save
Room occupancy energy save
No occupancy Auto-OFF
MENU ON
OFF
RETURN SELECT
HOLD
Energy saving option
Select: SELECT
No occupancy energy save
Cooling/Heating
MENU ON
OFF
RETURN SELECT
HOLD
Energy saving option
Select: SELECT
Room occupancy energy save
Cooling/Heating
MENU ON
OFF
RETURN SELECT
HOLD
Energy saving option
Select: SELECT
Time
No occupancy Auto-OFF
120 min.
MENU ON
OFF
RETURN SELECT
HOLD
MENU ON
OFF
RETURN SELECT
HOLD
18:47 Thu
Shut down by
No Occupancy Auto-OFF
31/Dec 12:59
Notes:
Any person at the following places cannot be detected.
Ɣ $ORQJWKHZDOORQZKLFKWKHDLUFRQGLWLRQHULVLQVWDOOHG
Ɣ 'LUHFWO\XQGHUWKHDLUFRQGLWLRQHU
Ɣ :KHUHDQ\REVWDFOHVXFKDVIXUQLWXUHLVEHWZHHQWKHSHUVRQDQG
the air conditioner
A person may not be detected in the following situations.
Ɣ 5RRPWHPSHUDWXUHLVKLJK
Ɣ $SHUVRQZHDUVKHDY\FORWKHVDQGKLVKHUVNLQLVQRWH[SRVHG
Ɣ $KHDWLQJHOHPHQWRIZKLFKWHPSHUDWXUHFKDQJHVVLJQL¿FDQWO\LV
present.
Ɣ 6RPHKHDWVRXUFHVVXFKDVDVPDOOFKLOGRUSHWPD\QRWEHVHQVHG
Ɣ $KHDWVRXUFHGRHVQRWPRYHIRUDORQJWLPH
The 3D i-see Sensor operates once approximately every 3 minutes
to measure the floor temperature and detect persons in the room.
Ɣ 7KHLQWHUPLWWHQWRSHUDWLQJVRXQGLVDQRUPDOVRXQGSURGXFHGZKHQ
the 3D i-see Sensor is moving.
Notes:
Ɣ During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
ƔAvailable directions depend on the type of unit connected.
ƔIn the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in “STAND BY” or “DEFROST” states.
,PPHGLDWHO\DIWHUVWDUWLQJKHDWPRGHZKLOHWKHV\VWHPLVZDLW-
LQJIRUWKHPRGHFKDQJHWRWDNHHIIHFW
3. In heat mode, when room temperature is higher than the tem-
perature setting.
3.7. Ventilation
For LOSSNAY combination
ŶThe following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
1RWHVIRUZLUHOHVVUHPRWHFRQWUROOHU
Ɣ Running the ventilator independently is not available.
Ɣ No indication on the remote controller.
6HDVRQDODLUÀRZIXQFWLRQ
Seasonal airflow
Select: SELECT
Seasonal airflow
Cooling/Heating
MENU ON
OFF
RETURN SELECT
HOLD
Seasonal airflow
Select: SELECT
Seasonal airflow
Cooling/Heating
1Select the setting with the [F4]
button.
2)) ĺ &RROLQJ RQO\ ĺ +HDWLQJ
RQO\ĺ&RROLQJ+HDWLQJĺ2))«
After changing the setting, press
the [SELECT/HOLD] button to
save the setting.
OFF: The function is disabled.
Coolingonly: Whenthe thermostat
turns off during cooling mode, the
vanes move up and down.
Heatingonly: Whenthe thermostat
turns off during heating mode,
the vanes move to the horizontal
DLUÀRZGLUHFWLRQWRFLUFXODWHWKHDLU
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
* In order to enable this function,
WKH DLUÀRZ GLUHFWLRQ PXVW EH VHW
to “Auto”.
1Select the desired menu with the
[F1] or [F2] button.
No occupancy energy save
If there are no persons in the room
for 60 minutes or more, energy-
saving operation equal to 2 °C,
4 °F is performed.
Room occupancy energy save
If the occupancy rate decreases
to approximately 30% of the maxi-
mum occupancy rate, energy-
saving operation equal to 1 °C,
2 °F is performed.
No occupancy Auto-OFF
If there are no persons in the
room for the set amount of time
(60–180 minutes), the operation
is automatically stopped.
2When No occupancy energy save
or Room occupancy energy save
is selected
Select the setting with the [F4]
button.
OFF ĺCooling only ĺHeating
only ĺCooling/Heating ĺ2))«
After changing the setting, press
the [SELECT/HOLD] button to
save the setting.
OFF: The function is disabled.
Cooling only: The function is ena-
bled only during cooling mode.
Heating only: The function is ena-
bled only during heating mode.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
3When No occupancy Auto-OFF is
selected
Set the time with the [F3] or [F4]
button.
ʊ7KHVHWWLQJLVGLVDEOHGWKHRS-
erationwill notstop automatically).
60 – 180: The time can be set in
10-minute increments.
4The message at left will appear
if the operation was stopped
automaticallyby theNo occupancy
Auto-OFF setting.