1. SPECIFICATIONS SMART MULTI
Outdoor model MXZ-SM72TAM-U1 MXZ-SM96TAM-U1 MXZ-SM120TAM-U1
Indoor Model Non-Ducted Ducted Non-Ducted Ducted Non-Ducted Ducted
Cooling capacity (Nominal)
*1
kW 21.1 28.1 35.2
Btu/h 72,000 96,000 120,000
Power input kW 5.67 8.16 10.7
Current input A 16.6-15.0 23.9-21.6 31.3-28.3
(Rated) kW 20.2 27 33.4
Btu/h 69,000 92,000 114,000
Power input kW 4.88 5.07 6.93 7.31 9.35 9.53
Current input A 14.3-12.9 14.8-13.4 20.2-18.3 21.4-19.3 27.3-24.7 27.8-25.2
Heating capacity (Nominal)
*2
kW 23.4 31.7 39.6
Btu/h 80,000 108,000 135,000
Power input kW 5.36 7.61 9.87
Current input A 15.7-14.2 22.2-20.1 28.8-26.1
(Rated) kW 22.6 30.2 37.8
Btu/h 77,000 103,000 129,000
Power input kW 4.86 5.12 6.86 7.24 9.11 9.21
Current input A 14.2-12.8 15.0-13.5 20.0-18.1 21.2-19.1 26.6-24.1 26.9-24.3
Power source 3-phase 3-wire 208-230V 60Hz
Breaker size (ODU only/ODU+IDU) A 40/60 50/70
Minimum Circuit Ampacity (ODU only/ODU+IDU) A 32/50 47/65
Maximum Overcurrent Protection (ODU only/ODU+IDU) A 58/76 84/102
Indoor unit
connectable
Total capacity 50 to 130% of outdoor unit cooling rated capacity
Model/ Quantity
*3
CITY MULTI 04 - 72 / 23 04 - 96 / 30 04 - 96 / 30
Branch box 06 - 36 / 12 06 - 36 / 12 06 - 36 / 12
Sound pressure level (SPL)
(measured in anechoic room)
dB <A> 53/54 58/59 61/62
Refrigerant piping
diameter
Liquid pipe in (mm) 3/8 (9.52)
*4
3/8 (9.52)
Gas pipe in (mm) 7/8 (22.2) 1-1/8 (28.58)
Fan
*5
Type × Quantity Propeller Fan × 2
m³/min 149 169 208
L/s 2,480 2,820 3,470
cfm 5,260 5,965 7,345
Control, Driving mechanism DC control
Motor output kW 0.285 + 0.285
External static press. 0 in.WG (0 Pa) / 0.12 in.WG (30 Pa)
Compressor Type × Quantity Scroll hermetic compressor× 1
Manufacturer Siam Compressor Industry Co., Ltd.
Starting method Inverter
Motor output kW 4.1 5.3 7.0
Case heater kW 0
Lubricant FVC68D 101oz. (3.0L)
Galvernized Steel Sheet Munsell No. 3Y 7.8/1.1
External dimension H × W × D mm 1,662 × 1,050 × 460 (+45)
in 65-7/16 × 41-11/32 × 187/64 (+ 1-49/64)
Protection
devices
High pressure protection High pressure switch
Inverter circuit (COMP./FAN) Overcurrent detection, Overheat detection (Heat sink thermistor)
Compressor Compressor thermistor, Overcurrent detection
Fan motor Overheating, Voltage protection
Refrigerant Type × original charge R410A 9.3 kg
Control Linear expansion valve
Net weight lb (kg) 432 (196)
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer) Double pipe heat exchanger
Defrosting method Reversed refrigerant circuit
Standard
attachment
Document Installation Manual
Accessory Joint pipe×1 set, Grounding lead wire ×1
Optional parts Joint: CMY-Y62-G-E/CMY-Y62-GA-E, Header: CMY-Y64/68-G-E
Guaranteed
operation range
Cooling D.B. -5 to 46°C [23 to 115°F]
*6*7*8
Heating W.B. -20 to 15°C [-4 to 59°F]
Remarks
*1. Nominal cooling conditions:
Indoor: 80°F D.B. /67 °F W.B. (26.7°C D.B./19.4°C W.B.)
Outdoor: 95°F D.B. (35.0°C D.B.)
*2. Nominal heating conditions:
Indoor: 70°F D.B. (21.1°C D.B.)
Outdoor: 47°F D.B./43°F W.B. (8.3°C D.B./6.1°C W.B.)
*3. It cannot be connected to mixed CITY MULTI indoor unit and branch box indoor unit.
*4. Liquid pipe diameter: 12.7mm, when further piping length is longer than 90m, and when PEFY-P72 or P96 is connected.
*5. It is possible to set the external static pressure to 30 Pa by Dip Switch.
*6. 5 to 115°F D.B. (-15 to 46°C D.B.), when an optional Air Outlet Guide is installed. However, this condition does not apply to the indoor units listed in *7.
*7. 50 to 115°F (10 to 46°C) D.B.: When connecting PKFY-P06NBMU, PKFY-P08NHMU, PKFY-P04/06/08/12NLMU, PFFY-P06/08/12NEMU, and
PFFY-P06/08/12NRMU type indoor unit.
*8. When the temperature is below 50°F D.B. (10 °C D.B.) with branch box system, noise could potentially occur.
Notes:
• Nominal conditions *1, *2 are subject to AHRI 1230.
•
• See the following for unit conversion: kcal/h = kW × 860, Btu/h = kW × 3,412, cfm = m³/min × 35.31, lb = kg × 0.4536
•
• Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation