Mitsubishi Electric MELSEC SW1DNC-CCIEF-B User manual

CC-Link IE Field Network Interface Board
User's Manual (For SW1DNC-CCIEF-B)
-Q80BD-J71GF11-T2
-Q81BD-J71GF11-T2


1
SAFETY PRECAUTIONS
(Read these precautions before using this product.)
Before using this product, please read this manual and the relevant manuals carefully and pay full attention to safety to handle
the product correctly.
The precautions given in this manual are concerned with this product only. For the safety precautions of the programmable
controller system, refer to the user's manual for the CPU module used.
In this manual, the safety precautions are classified into two levels: " WARNING" and " CAUTION".
Under some circumstances, failure to observe the precautions given under " CAUTION" may lead to serious
consequences.
Observe the precautions of both levels because they are important for personal and system safety.
Make sure that the end users read this manual and then keep the manual in a safe place for future reference.
[Design Precautions]
[Design Precautions]
WARNING
●Configure safety circuits external to the programmable controller to ensure that the entire system
operates safely even when a fault occurs in a personal computer. Failure to do so may result in an
accident due to an incorrect output or malfunction.
(1) Emergency stop circuits, protection circuits, and protective interlock circuits for conflicting
operations (such as forward/reverse rotations or upper/lower limit positioning) must be configured
external to the programmable controller.
(2) The station to which the board is installed may be disconnected from the data link due to a data
link error. If this occurs, the data output from the station and written to other stations before the
error will be held until the station is reconnected to the network (until its data link is
restarted).Provide a mechanism for data link status monitoring and error handling for each station
that is connected to the data link system.
●For the operating status of each station after a communication failure, refer to this manual. Incorrect
output or malfunction due to a communication failure may result in an accident.
●When changing data during operation, configure an interlock circuit in the program to ensure that the
entire system will always operate safely. And determine corrective actions to be taken between the
personal computer and CPU module in case of a communication failure.
CAUTION
●Do not install the control lines or communication cables together with the main circuit lines or power
cables.
Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to
noise.
WARNING Indicates that incorrect handling may cause hazardous conditions, resulting in
death or severe injury.
CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in
minor or moderate injury or property damage.

2
[Installation Precautions]
[Installation Precautions]
[Wiring Precautions]
WARNING
●Turn off the power for the system in all phases before installing the board to or removing it from the
personal computer. Failure to do so may result in electric shock or cause the board to fail or
malfunction.
●Do not touch any connectors while power is on. Doing so may cause electric shock or malfunction.
CAUTION
●Use the board in an environment that meets the general specifications in this manual. Failure to do so
may result in electric shock, fire, malfunction, or damage to or deterioration of the product.
●Do not directly touch any conductive parts and electronic components of the board. Doing so can
cause malfunction or failure of the board.
●Do not disassemble or modify the boards. Doing so may cause failure, malfunction, injury, or a fire.
●Fix the board by tightening the board-fixing screws within the specified torque range. Undertightening
may cause drop, short circuit, or malfunction. Overtightening may damage the screw and/or board,
resulting in drop, short circuit, or malfunction.
For the tightening torque of the board-fixing screws, refer to the manual supplied with the personal
computer.
●Before handling the board, touch a conducting object such as a grounded metal to discharge the static
electricity from the human body. Failure to do so may cause the board to fail or malfunction.
●Install the board to a personal computer which is compliant with PCI standard or PCI Express
standard (Page 31 Operating Environment). Failure to do so may cause a failure or malfunction.
●Securely insert the board into the PCI slot following the board installation instruction of the personal
computer. Incorrect insertion of the board may cause malfunction, failure, or drop of the board.
●When installing the board, take care not to contact with other boards.
●When installing the board, take care not to get injured by an implemented component or a surrounding
member.
●Handle the board in a place where static electricity will not be generated. Failure to do so may cause
a failure or malfunction.
●The board is included in an antistatic envelope. When storing or transporting it, be sure to put it in the
antistatic envelope. Failure to do so may cause a failure or malfunction.
●Do not drop or apply a strong impact to the board. Doing so may cause a failure or malfunction.
WARNING
●Turn off the power for the system in all phases before installing the board or starting wiring. Failure to
do so may result in electric shock, damage to the product, or malfunction.
●After installation of the board and wiring, attach the cover on the module before turning it on for
operation. Failure to do so may result in electric shock.

3
[Wiring Precautions]
[Startup and Maintenance Precautions]
[Startup and Maintenance Precautions]
CAUTION
●Place the communication cable connected to the board in a duct or clamp them. If not, dangling
cables may swing or inadvertently be pulled, resulting in damage to the board or cables or
malfunctions due to poor contact.
●When disconnecting the cable from the board, do not pull the cable by the cable part. Pulling the cable
connected to the board may result in malfunction or damage to the board or cable.
●Prevent foreign matter such as dust or wire chips from entering the personal computer. Such foreign
matter may cause a fire, failure, or malfunction.
●Do not install the communication cables together with the main circuit lines or power cables. Keep a
distance of 100mm or more between them. Failure to do so may result in malfunction due to noise.
●Securely plug the communication cable to the connector of the board. Then, check for any incomplete
connection. Poor contact may cause an erroneous input or output.
●Always ground the personal computer to the protective ground conductor. Failure to do so may cause
a malfunction.
WARNING
●Turn off the power for the system in all phases before cleaning the board or retightening the board-
fixing screws. Failure to do so may result in electric shock, or cause a failure or malfunction of the
board.
●Turn off the power for the system in all phases before installing the board to or removing it from the
personal computer. Failure to do so may result in electric shock or cause the board to fail or
malfunction.
●Do not connect or disconnect any communication cable while power is on. Doing so may result in a
malfunction.
CAUTION
●Thoroughly read the manual and ensure the safety before performing program modification during
operation, forced output, operation such as RUN, STOP, and PAUSE. An improper operation will
result in mechanical damage or accidents.
●Do not disassemble or modify the boards. Doing so may cause failure, malfunction, injury, or a fire.
●Fix the board by tightening the board-fixing screws within the specified torque range. Undertightening
may cause drop, short circuit, or malfunction. Overtightening may damage the screw and/or board,
resulting in drop, short circuit, or malfunction.
For the tightening torque of the board-fixing screws, refer to the manual supplied with the personal
computer.
●Before handling the board, touch a conducting object such as a grounded metal to discharge the static
electricity from the human body. Failure to do so may cause the board to fail or malfunction.
●The board is included in an antistatic envelope. When storing or transporting it, be sure to put it in the
antistatic envelope. Failure to do so may cause a failure or malfunction.
●The microprocessor built in the board will reach a high temperature during operation. Do not touch it
directly when replacing the board. Doing so may result in a failure, malfunction or injury.

4
[Disposal Precautions]
CAUTION
●When disposing of this product, treat it as industrial waste.

5
CONDITIONS OF USE FOR THE PRODUCT
(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;
i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident;
and
ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the
case of any problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of being used in general industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED TO ANY AND ALL
RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY
INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE
OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR
WARNING CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL
BULLETINS AND GUIDELINES FOR the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT in;
• Nuclear Power Plants and any other power plants operated by Power companies, and/or any other cases in which the
public could be affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases in which establishment of a special quality
assurance system is required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as Elevator and Escalator,
Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for Recreation and Amusement, and
Safety devices, handling of Nuclear or Hazardous Materials or Chemicals, Mining and Drilling, and/or other
applications where there is a significant risk of injury to the public or property.
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or
more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific
applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or
other safety features which exceed the general specifications of the PRODUCTs are required. For details, please
contact the Mitsubishi representative in your region.

6
CONSIDERATIONS FOR USE
Interlink transfer and routing functions
CC-Link IE Field Network board cannot be used as a relay station for the interlink transfer function or the routing function.
To use these functions, set a network module as a relay station.
Driver installation and updating
The consistency between the driver and utility cannot be identified, and CC-Link IE Field Network board may not operate
properly.
Do not install or update the driver other than the method written in the troubleshooting.
Page 141 TROUBLESHOOTING
INTRODUCTION
Thank you for purchasing the Mitsubishi Electric network interface boards.
This manual describes the required system configuration, specifications, operating procedure, functions, and troubleshooting
of the relevant products listed below.
Before using this product, please read this manual and the related manuals carefully and develop familiarity with the functions
and performance of the CC-Link IE Field Network interface board to handle the product correctly.
Please make sure that the end users read this manual.
Relevant products
Q80BD-J71GF11-T2, Q81BD-J71GF11-T2

7
CONTENTS
CONTENTS
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
CONDITIONS OF USE FOR THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CONSIDERATIONS FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
RELEVANT MANUALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
TERMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
PACKING LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
CHAPTER 1 OVERVIEW 16
1.1 CC-Link IE Field Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.2 CC-Link IE Field Network Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
CHAPTER 2 SYSTEM CONFIGURATION 20
2.1 System Configuration Using CC-Link IE Field Network Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
2.2 CC-Link IE Field Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Single Network System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Multi-Network System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.3 Network Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.4 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CHAPTER 3 SPECIFICATIONS 35
3.1 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.2 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
3.3 List of Buffer Memory Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
CHAPTER 4 PROCEDURE BEFORE OPERATION 40
4.1 Procedure Before Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.2 Part Names. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Operation LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Handling precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Installation environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Procedure for replacing mounting brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Board installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.4 Setting Channel Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4.5 Tests Before Wiring (Standalone Tests of the Board) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Bus I/F test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Memory test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Hardware test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Self-loopback test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
4.6 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Wiring Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Ethernet cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
4.7 Tests After Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

8
Loop test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Cable test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Communication test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
CHAPTER 5 FUNCTIONS 58
5.1 Function List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
5.2 Cyclic Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Data flow and link device assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Link scan and link refresh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Assurance of cyclic data integrity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Input status of data link faulty station setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Cyclic transmission stop and restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
5.3 Transient Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Communication on the same network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Communication with different networks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
5.4 SEND/RECV Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
5.5 Reserved Station Specification and Reserved Station Function Disable Function . . . . . . . . . . . . . . . . . . 75
5.6 Error Invalid Station and Temporary Error Invalid Station Setting Function. . . . . . . . . . . . . . . . . . . . . . . . 76
5.7 Event Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
5.8 Loopback Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
5.9 Driver WDT function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
CHAPTER 6 INSTALLING AND UNINSTALLING SOFTWARE PACKAGES 80
6.1 Installation and Uninstallation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
6.2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
When installation is completed normally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
When installation is aborted or failed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
6.3 Uninstallation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Uninstallation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
When uninstallation is completed normally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
When uninstallation is failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
CHAPTER 7 OVERVIEW OF CC IE FIELD UTILITY 83
7.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
7.2 Menu List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
CHAPTER 8 SCREEN CONFIGURATION AND BASIC OPERATIONS 85
8.1 Starting and Exiting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
8.2 Screen Configuration and Basic Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Main frame configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Toolbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Work windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
8.3 Help Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
CHAPTER 9 PROJECT MANAGEMENT 91
9.1 Creating Projects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
9.2 Opening Existing Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
9.3 Saving Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
9.4 Saving Projects with Compression and Unpacking Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94

9
CONTENTS
9.5 Deleting Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
9.6 Closing Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
9.7 Verifying Project Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
CHAPTER 10 SETTING PARAMETERS 98
10.1 Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
10.2 Setting Network Parameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Network type and mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Network configuration setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Network operation setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Event setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Driver setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Target setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Routing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
CHAPTER 11 OPERATING BOARD ONLINE 112
11.1 Setting Board Channel Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
11.2 Writing/Reading Parameters to/from Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
11.3 Verifying Parameters of Board and Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
11.4 Resetting Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
CHAPTER 12 MONITORING 115
CHAPTER 13 DIAGNOSING BOARD STATUS 117
13.1 Diagnosing Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
13.2 Diagnosing CC-Link IE Field Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Selecting the diagnostics target. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Displaying diagnostics screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Communication test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Cable test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Link start/stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Network event history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Reserved station function enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Enable/Disable ignore station errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
CHAPTER 14 MELSEC DATA LINK LIBRARY 137
CHAPTER 15 PROGRAMMING 139
15.1 Precautions on Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
CHAPTER 16 TROUBLESHOOTING 141
16.1 Error Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
16.2 Troubleshooting for Installation/Uninstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Installation failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Uninstallation failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Action displayed on the screen is not effective while installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
When the driver is not installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
16.3 Troubleshooting for Personal Computer and Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Personal computer does not start or shuts down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Utility does not startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

10
The screen or operation is abnormal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
The screen for which corrective action is not clear, is displayed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Personal computer operates slowly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
16.4 Troubleshooting for Board and Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Hardware error or board WDT error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Driver WDT error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Driver does not start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Bus error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
16.5 Troubleshooting for Data Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Communication error (ERR. LED is ON/Flashing) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
User program cannot access CPU modules other than QCPU (Q mode) and MELSEC iQ-R series CPU
modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Communication cannot be performed occasionally when executing user program . . . . . . . . . . . . . . . . . . . . . 153
Station is disconnected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Communication is unstable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
16.6 Troubleshooting for Device Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
Cyclic transmission cannot be performed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
Transient transmission cannot be performed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
16.7 Checking method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Checking installation environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Check the board installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Checking cables and wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Checking operation environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Checking personal computer and operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Checking on Device Manager screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Checking operations with event viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Checking channel numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Checking operations with board diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Checking operations with tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Checking LED status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Checking network status with CC-Link IE Field Network diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Checking network status with monitoring link special relays (SB) and link special registers (SW) . . . . . . . . . . 164
Checking communication status with monitoring access target device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
16.8 Information Required for Inquiries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
16.9 Error Code List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
APPENDIX 176
Appendix 1 Precautions for Accessing Redundant CPU System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Redundant CPU specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Operation at occurrence of system switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Retry processing for the error that occurs during system switching processing . . . . . . . . . . . . . . . . . . . . . . . . 177
Automatic switching of communication path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Appendix 2 Details of Buffer Memory Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Link device area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Offset/size information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Own station information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Other station information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Appendix 3 Link Special Relay (SB) List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Appendix 4 Link Special Register (SW) List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Appendix 5 Processing Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216

11
CONTENTS
Link refresh time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Link scan time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Transmission delay time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Appendix 6 Differences in Cyclic Transmission Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Appendix 7 Comparison of CC-Link and CC-Link IE Field Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Appendix 8 Combinations with Existing Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Appendix 9 Checking Serial Number and Function Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Appendix 10New and Improved Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Change of hardware function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Update of software package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Appendix 11Restrictions for Operating System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Appendix 12Windows Warning Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Overview of warning message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Methods for preventing warning message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Appendix 13Behavior When Personal Computer Enters Power Save Mode or Fast Startup . . . . . . . . . . . . . . . 230
Behavior when the personal computer enters the power save mode (hibernate, sleep). . . . . . . . . . . . . . . . . . 230
Behavior when fast startup function is enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Appendix 14MELSECPowerManager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Installing MELSECPowerManager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Uninstalling MELSECPowerManager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Checking MELSECPowerManager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Appendix 15EMC and Low Voltage Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Measures to comply with the EMC Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Measures to comply with the Low Voltage Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Appendix 16External Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Q80BD-J71GF11-T2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Q81BD-J71GF11-T2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
INDEX 240
REVISIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243
TRADEMARKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244

12
RELEVANT MANUALS
e-Manual refers to the Mitsubishi FA electronic book manuals that can be browsed using a dedicated tool.
e-Manual has the following features:
• Required information can be cross-searched in multiple manuals.
• Other manuals can be accessed from the links in the manual.
• The hardware specifications of each part can be found from the product figures.
• Pages that users often browse can be bookmarked.
Manual name [manual number] Description Available form
CC-Link IE Field Network Interface Board User's
Manual (For SW1DNC-CCIEF-B)
[SH-080980ENG] (this manual)
Overview of system configuration, specifications, functions, handling, wiring,
and troubleshooting for CC-Link IE Field Network interface board.
Print book
e-Manual
PDF
MELSEC-Q CC-Link IE Field Network Master/Local
Module User's Manual
[SH-080917ENG]
Overview of the CC-Link IE Field Network, and specifications, procedures
before operation, system configuration, installation, wiring, settings, functions,
programming, and troubleshooting for MELSEC-Q series CC-Link IE Field
Network master/local modules.
Print book
PDF
MELSEC iQ-R Ethernet/CC-Link IE User's Manual
(Startup)
[SH-081256ENG]
Specifications, procedures before operation, system configuration, wiring, and
communication examples of Ethernet, CC-Link IE Controller Network, and CC-
Link IE Field Network
Print book
e-Manual
PDF
MELSEC iQ-R CC-Link IE Field Network User's
Manual (Application)
[SH-081259ENG]
Functions, parameter settings, programming, troubleshooting, I/O signals, and
buffer memory of CC-Link IE Field Network
Print book
e-Manual
PDF
MELSEC-L CC-Link IE Field Network Master/Local
Module User's Manual
[SH-080972ENG]
Overview of the CC-Link IE Field Network, and specifications, procedures
before operation, system configuration, installation, wiring, settings, functions,
programming, and troubleshooting for MELSEC-L series CC-Link IE Field
Network master/local modules.
Print book
e-Manual
PDF
MELSEC Data Link Library Reference Manual
[SH-081035ENG]
Programming, function specifications, and sample programming for MELSEC
data link library.
Print book
e-Manual
PDF

13
TERMS
Unless otherwise specified, this manual uses the following terms.
Term Description
Baton pass A token to send data over a network.
Board WDT Watchdog timer that monitors the operating status of network board.
Buffer memory A memory which is used to store data for communication between the CC-Link IE Field Network board and the master/local
module.
CC IE Field Utility Name for the utility included in the SW1DNC-CCIEF-B CC-Link IE Field Network software package.
CC-Link IE Controller Network
board
A generic term for the Q80BD-J71GP21-SX, Q80BD-J71GP21S-SX, Q81BD-J71GP21-SX, and Q81BD-J71GP21S-SX
CC-Link IE Controller Network interface board.
CC-Link IE Field Network board A generic term for the Q80BD-J71GF11-T2 and Q81BD-J71GF11-T2 CC-Link IE Field Network interface board.
CC-Link Ver.2 board A generic term for the Q80BD-J61BT11N and Q81BD-J61BT11 CC-Link system master/local interface board.
CPU module A generic term for the MELSEC iQ-R series, or MELSEC-Q/L series CPU module.
Cyclic transmission A function by which data are periodically exchanged among stations on the same network using link devices (RX, RY,
RWw, and RWr).
Data link A generic term for cyclic transmission and transient transmission.
Dedicated instruction An instruction that simplifies programming for using functions of intelligent function modules.
Device A device (X, Y, M, D, or others) in a CPU module.
Disconnection A process of stopping data link if a data link error occurs.
Driver WDT An abbreviation for the watchdog timer that monitors the communication status between a network board and a personal
computer, or operating status of a personal computer.
Ethernet adapter module An abbreviation for the NZ2GF-ETB CC-Link IE Field Network Ethernet adapter module.
GX Developer A generic product name for SW8D5C-GPPW.
GX Works2 A generic product name for SWnDND-GXW2 and SWnDNC-GXW2. ('n' indicates its version.)
Head module An abbreviation for the LJ72GF15-T2 CC-Link IE Field Network head module.
Intelligent device station A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This
station responds to a transient transmission request from another station and also issues a transient transmission request
to another station.
Intelligent function module A MELSEC-Q/L series module that has functions other than input and output, such as an A/D converter module and D/A
converter module.
Link device A device (RX, RY, RWw, or RWr) in a module and board of CC-Link IE Field Network.
Link refresh Data transfer between link devices of CC-Link IE Field Network board and the driver.
Link scan (Link scan time) Time required for all the stations on the network to transmit data. The link scan time depends on data volume and the
number of transient transmission requests.
Link special register (SW) Word data that indicates the operating status and data link status of a module or board on CC-Link IE Field Network.
Link special relay (SB) Bit data that indicates the operating status and data link status of a module or board on CC-Link IE Field Network.
Local station A station that performs cyclic transmission and transient transmission with the master station and other local stations.
Loopback A function that disconnects the station in which an error has occurred, and continues data link with the stations that are
operating normally. Stations connected after the faulty station can also continue data link.
Master station A station that controls the entire network. This station can perform cyclic transmission and transient transmission with all
stations. Only one master station can be used in a network.
Master/local module A generic term for the QJ71GF11-T2 and LJ71GF11-T2 CC-Link IE Field Network master/local module.
MD function A generic term for functions in MELSEC data link library.
MELSECNET/H board A generic term for the Q80BD-J71LP21-25, Q81BD-J71LP21-25, Q80BD-J71LP21S-25, Q80BD-J71LP21G, Q80BD-
J71LP21GE, and Q80BD-J71BR11 MELSECNET/H interface board.
Network module A generic term for the following modules:
• CC-Link IE Field Network module
• CC-Link IE Controller Network module
• MELSECNET/H module
• MELSECNET/10 module
RAS An abbreviation for Reliability, Availability, and Serviceability. This term refers to usability of automated equipment.
Reconnection A process of restarting data link when a station recovers from an error.
Relay station A station that includes two or more network modules. Data are passed through this station to stations on other networks.
Remote device station A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This
station responds to a transient transmission request from another station.
Remote head module An abbreviation for RJ72GF15-T2 CC-Link IE Field Network remote head module.

14
Remote I/O station A station that exchanges I/O signals (bit data) with the master station by cyclic transmission.
Remote input (RX) Bit data input from a slave station to the master station. (For some areas in a local station, data are input in the opposite
direction.)
Remote output (RY) Bit data output from the master station to a slave station. (For some areas in a local station, data are output in the opposite
direction.)
Remote register (RWr) Word data input from a slave station to the master station. (For some areas in a local station, data are input in the opposite
direction.)
Remote register (RWw) Word data output from the master station to a slave station. (For some areas in a local station, data are output in the
opposite direction.)
Reserved station A station reserved for future use. This station is not actually connected, but counted as a connected station.
Routing A process of selecting paths for communication with other networks.
CC-Link IE Field Network requires communication paths to be preset using routing parameters to communicate with
stations on different networks.
Slave station A generic term for a local station, remote I/O station, remote device station, and intelligent device station.
SW1DNC-CCIEF-B A product name of the software package for CC-Link IE Field Network board.
Transient transmission A function of communication with another station, which is used when requested by dedicated instruction or utility.
Term Description

15
PACKING LIST
The following items are included in the package of this product. Before use, check that all the items are included.
Q80BD-J71GF11-T2
Q81BD-J71GF11-T2
Before Using the Product
Software license agreement
SW1DNC-CCIEF-B
CC-Link IE
Field Network
software package
(CD-ROM)
Q80BD-J71GF11-T2 CC-Link IE
Field Network Interface Board
Before Using the Product
Software license agreement
Low Profile Bracket
SW1DNC-CCIEF-B
CC-Link IE
Field Network
software package
(CD-ROM)
Q81BD-J71GF11-T2 CC-Link IE
Field Network Interface Board

16 1 OVERVIEW
1.1 CC-Link IE Field Network
1OVERVIEW
1.1 CC-Link IE Field Network
CC-Link IE Field Network is a high-speed and large-capacity open field network that is based on Ethernet technology
(1000BASE-T).
Data communication
High-speed and large-capacity data communication is available between a master station and slave stations on the CC-Link
IE Field Network.
■Periodic communication (cyclic transmission)
Data is periodically communicated among stations within the same network. (Page 60 Cyclic Transmission)
■Non-periodic communication (transient transmission)
Data is communicated upon request. (Page 68 Transient Transmission)
1 Gbps communication speed
1 Gbps communication speed allows high-speed communication. Also, the tact time can be reduced due to the improved
performance of communication response.
RX RX
RY RY
X
Y
W
RWw RWw
RWr RWr
Personal computer Programmable controller
User
program
Driver
Board
Master/
local
module
CPU
module
1234H
1234H
Write request Device
Write data
CPU module
Local station
Board
User program

1 OVERVIEW
1.1 CC-Link IE Field Network 17
1
Use of Ethernet cable
A 1000BASE-T-compliant Ethernet is used for the connection interface. The wiring cost can be reduced because 1000BASE-
T-compliant Ethernet cables are commercially available. (Page 30 Cables)
Flexible wiring for the system arrangements
The network can be wired into star topology, line topology, and ring topology. (Page 21 Network configuration)
For star topology, a 1000BASE-T design switching hub can be used. (Page 30 Hubs)
Wiring is highly flexible because a network can consist of a combination of star and line topologies. For example, the control
panels can be connected through a star topology and the production lines through a line topology.
1000BASE-T
Star topology
Line topology Line topology

18 1 OVERVIEW
1.2 CC-Link IE Field Network Board
1.2 CC-Link IE Field Network Board
CC-Link IE Field Network board allows the connection of a personal computer to CC-Link IE Field Network.
CC-Link IE Field Network board can be used as either a master station or local stations of CC-Link IE Field Network.
A personal computer can be easily connected to CC-Link IE Field Network
A system which contains a personal computer as a master station or local stations of the CC-Link IE Field Network system
can be configured.
System controls and high-speed data collection
For a reduction of tact time in a manufacturing system, control data, logging data of manufacturing processes, management
data for traceability, and management/diagnostic data for equipment predictive maintenance can be collected at high speed
and monitored.
A control system using a programming language such as C language can be configured when a personal computer is used as
a master station.
Control data and logging data can be collected at high speed when a personal computer is used as a local station.
CC-Link IE
Field Network
A control system using a programming
language such as C language can be
configured when a personal computer
is used as a master station.
Control data and logging data can be
collected at high speed when a personal
computer is used as a local station.
This manual suits for next models
2
Table of contents
Other Mitsubishi Electric Computer Hardware manuals

Mitsubishi Electric
Mitsubishi Electric DX-ZD6UE User manual

Mitsubishi Electric
Mitsubishi Electric GT10-LDR User manual

Mitsubishi Electric
Mitsubishi Electric VC-X3000 User manual

Mitsubishi Electric
Mitsubishi Electric M32R Series User manual

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 User manual

Mitsubishi Electric
Mitsubishi Electric SW0DNC-MNETH-B User manual

Mitsubishi Electric
Mitsubishi Electric Q80BD-J71GP21-SX User manual

Mitsubishi Electric
Mitsubishi Electric Apricot HP DDS DRIVES User manual

Mitsubishi Electric
Mitsubishi Electric GOT2000 Series User manual

Mitsubishi Electric
Mitsubishi Electric CNC MELDASMAGIC Series User manual