Eng-2
CAUTION Incorrect handling of the product may result in injury or damage to property or
household effects.
Prohibited
Do not use the Lossnay unit at locations
where toxic gas or gas containing
corrosive components such as acids,
alkaline, organic solvents, or paints is
generated.
Failure to heed this warning may result in
malfunction.
Do not place objects under the product.
Dew condensation water may drip.
During cleaning and maintenance, do not
climb on an unstable stand.
Injury may result if you tumble down.
Follow
instructions
Do not spray the Lossnay unit, wall switch, or supply air/
exhaust grille with a insecticide, hair, or cleaning spray.
Failure to heed this warning may deform or damage parts.
This appliance is not intended for use by persons (including
children) with reduced physical sensory or mental capabilities,
or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the
appliance. (This appliance can be used by children aged from
8 years and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without
supervision.)
Follow
instructions
Make sure that drain piping is installed at
the discharge outlet.
Wear gloves during cleaning and maintenance.
Failure to heed this warning may result in injury.
When removing the supply air lter case and
exhaust lter case, dew condensation water
that has built up inside sometimes drips. So,
remove the lter cases gently by supporting
them with both hands so that they are not tilted.
Securely install the parts after cleaning
and maintenance.
Injury may result if the parts should fall.
1. Safety Precautions (continued)
2. Features
Requests on Use
- When this product ventilates, it takes in cold air from the outside in winter. For this reason, when the outside air temperature drops,
moisture in the air around the product condensates, and water drops sometimes adhere to the product or drop. This, however, is not a
malfunction. Wipe off any water droplets.
- When outside air temperatures are low and operation of the product is stopped, operation of the ventilator or pressure of the outside wind
might cause outside air to ow in from the product, which may result in dew condensation forming on the product and other parts. This is
not a malfunction. Wipe off any water droplets.
- When a lot of humidity is generated from building materials at newly built houses, dew condensation may form on the product and other
parts. This is not a malfunction. Wipe off any water droplets.
- When a strongly fragrant scent, etc. is used in toilets, bath rooms and wash basins, or when cigarette or other smoke is discharged, odor is
sometimes sense from the air vent.
- Operating noise may be a cause of concern directly underneath the product.
- When ventilating a bathroom, operate the product for 24 hours.
What is the LOSSNAY HEAT RECOVERY VENTILATOR…?
■
Effective ventilation routes can be achieved in the entire house by the supply air vent and the exhaust vent being installed at
locations away from each other depending on the duct connection method.
■
Built-in lters reduce the inux of dust, pollen, etc, in outside air before the air is supplied to rooms.
During heat exchanger operation
Dirty air from inside the room is discharged (=exhaust), and clean air from the outside is taken into the room (=air supply).
During this time, air is discharged and taken in through the Lossnay core (heat exchanger). As a result, air is ventilated while
reusing (heat collection) the warmth or coolness of the room which is discarded during ventilation.
■
When air conditioning is used in summer and winter, heat exchange ventilation reduces the load placed on air conditioning to
ensure energy savings.
During “By-pass” operation
When exhaust and air supply are performed, air is supplied to the room without any change in the outside air temperature due to
exhaust being performed without passing through the Lossnay core.
*
This function can be used only when the optional motorized damper (P-133DUE-E) is used.
■
In spring and fall, and summer nights, for example, the cool air of the outside is taken in.