Mitsubishi MJ-E16S-S1 User manual

ADVANCED AND EVER ADVANCINGMITSUBISHI ELECTRIC
DEHUMIDIFIER 2003
SERVICE MANUAL No.MJW-21
MJ-E16S/E16SX-S1Model
Sold from 2003
CONTENTS
1. PRODUCT SPECIFICATIONS........................................................................................ 2
2. OUTER DIMENSIONS .................................................................................................... 3
3. EXTERNAL VIEW, PARTS AND DISPLAY SECTION................................................ 3 ~ 8
4. TECHNICAL POINTS.................................................................................................. 8 ~ 10
5. DAILY CHECKS AND MAINTENANCE ........................................................................ 11
6. WIRING DIAGRAM AND BLOCK DIAGRAM
6.1 Wiring Diagram....................................................................................................... 12
6.2 Function List ....................................................................................................... 13 ~ 15
6.3 Timing Charts ..................................................................................................... 16 ~ 20
6.4 Board Diagrams (Component Side) ....................................................................... 21
6.5 General Block Diagram ...................................................................................... 22 ~ 25
7. TROUBLESHOOTING PROCEDURE
7.1 Troubleshooting flowchart ..................................................................................... 26
7.2 One-Point Service .............................................................................................. 26 ~ 27
7.3 Key Component Check Procedures ....................................................................... 27
7.4 Error Indications and Corrective Actions ............................................................... 28
7.5 Self-Test Program and Execution Procedure .................................................... 28~ 30
8. DISASSEMBLY AND REASSEMBLY HINTS ........................................................... 31~ 34
9. CONTINUOUS WATER DRAINAGE ............................................................................. 35
PARTS CATALOG .......................................................................................................... 36~ 43
10. TROUBLESHOOTING................................................................................................ 44~ 45
PRECAUTIONS ............................................................................................................... 46~ 47

2
1. Product specifications
Easy Dehumidifying
* The brackets [ ] enclose values measured at a room
temperature of about 15°C or lower.
16.0
41
37
single phase, 220-240V, 50Hz
275
1.3
5.5
Metallic Blue (A)
570 ×384 ×183
11.7
HFC - 134a, 120g
Slit fin
Slit fin
Thermal overcurrent relay
XB460 VTE (rotary)
150
Primary: 26.1 , subsidiary: 70.7
With temperature fuse
Sirocco fan
16
4
1 ~ 35 (°C)
Hot gas type
Built-in humidity sensor
Reed switch (automatic)
Auto-stopper tripped with about 4.0 liters of water
Commercial hose (inside diameter 15 mm)
LOW · EASY DEHUMIDIFYING · LOW TEMP · AIR PURIFIER (E16S) · LAUNDRY ·
AUTO (E16SX) · MILDEW GUARD (E16SX)
Ye s
16A
MJ-E16S-S1 MJ-E16SX-S1
Item
Power supply (phases,V,Hz)
Power consumption (W)
Operating current (A)
Starting current (A)
Color tone
Dimensions (H ×W ×D mm)
Weight (kg)
Coolant quantity (g)
Evaporator
Condenser
Defrosting method
Humidity control
Tank full protection
Tank capacity (liters)
Continuous drainage
Operation modes
Timer
Air cleaning performance
Plug socket rating
Model
(30°C room temperature, 80% relative humidity) (liters/day)
Laundry
Performance
Product performance
CompressorBlower
Electrical
characteristics
Operating noise
levels(dB)
Compressor protection
Model
Output (W)
Winding resistance (Ω)
Blower protection
Type
Output (W)
Flow rate selection
Speed (rpm)
Flow rate (m3/min)
Operating room
temperature (reference) (°C)
Air purifier
Laundry
Low
Low Temp
Mildew Guard
Indications
The operating noise levels indicated are
typical values measured in our anechoic room.
700
675-700
720 [740]*
675-700
2.5
675-700
2.4-2.5
[740]*
675-700
[2.7]
2.4-2.5
2.4-2.5
2.6 [2.7]*
2.4-2.5
Auto
Laundry
720 [740]*
675-700
2.4-2.5
2.6 [2.7]*
Continuous dehumidi-
fying
LAUNDRY ·
AIR PURIFIER ·
OFF TIMER
(2 · 4 · 8h)
LOW · LOW TEMP ·
EASY DEHUMIDIFYING ·
TANK FULL · COLD ·
DEFROST
LAUNDRY · MILDEW GUARD · AUTO ·
CURRENT HUMIDIFY · SELECTION HUMIDIFY ·
ON/OFF TIMER(1-9h) · SWING LOUVRE(WIDE,
UPWARD, REAR) · CHILD LOCK
Dehumidifying capacity
On/Off timer (1-9h)
Off timer (2 · 4 · 8h)
E16S Common E16SX
E16S Common E16SX

Continuous
drainage outlet
Sensor
Do not cover
Power Plug
Air purifying filter
Already installed at time of purchase
Side air intakes (left/right)
Do not block
Handle
Raise handle to transport
3
2. Outer Dimensions
3. External View, Parts and Display Section
Front
Back
Louvre
Air filter
Tank Lid
Control Panel
Floating element
Front
panel
Front door
The water tank may contain water residue at
time of purchase. This is from final product
testing at the factory and is not due to a defect.
Water Tank
E16SX

4
Control Panel
¡Lamp
Current mode lights
¡Selection button
Switches modes
¡Mode button
For switching from one operating
mode to another.
¡Child lock
To set the child lock, press the
mode button for three seconds.
¡
Humidity Selection
This is used to set the target
humidity.
¡Swing louvre button
Sets swing louvre
direction or locks it
into position
¡Tank full lamp
This lights up to warn that
the water tank is full.
6 operating modes
SELECTION
¡EASY
DEHUMIFYING
¡LAUNDRY
MODE
¡LOW
¡
MILDEW GUARD
¡LOW TEMP
¡AUTO
¡Power lamp
Lights when unit is ON.
¡Power button
Use this to switch the
unit ON and OFF.
¡Timer ON/OFF
Sets timer
LCD Panel
¡Mode Indicator
Indicates the current
operating mode.
¡Humidity Indicator
This indicates the
approximate humidity.
...indicates the
current humidity
...indicates the
humidity setting in
AUTO mode
The current humidity is displayed
in a range from 30 to 80%.
¡Information display
Indicates room and unit
condition
...Flashes when the power is
OFF and the humidity rises
...Lights when the defrosting
function is operating.
...Lights when the power is
ON and the room
temperature drops below
15°C.
The LCD panel provides an explanation of all operations.
¡Swing monitor
Indicates the direction
of the swing louvre.
¡Timer display
Displays the time set
for the ON/OFF timer.
¡Child lock Indicator
Appears when the child
lock is on.
¡
COLD Lamp
Lights when the room
temperature drops
below 15°C
¡
DEF Lamp
Lights during
Defrosting mode
¡Lamp
Current mode lights
¡Auto button
For swiching mode the
EASY DEHUMIDIFYING
¡Mode button
For switching from one
operating mode to
another
¡OFF Timer Lamp
Set time lights
¡OFF Timer button
For setting the Timer
¡Power button
Use this to switch the
unit OFF and ON.
5 operating modes
Auto
¡EASY
DEHUMIDIFYING
MODE
¡LOW
¡LAUNDRY
¡LOW TEMP
¡AIR PURIFIER
¡Tank full Lamp
This lights up to warn that the
water tank is full.
MJ-E16S
MJ-E16SX

5
¡Auto
The unit maintains the humidity level by
automatically controlling airflow and operating
intermittently as necessary. All you have to do
is set the humidity level.
¡The unit turns off when current humidity
decreases past the set humidity level, and
restarts when the level is exceeded.
¡The unit operates for 6 minutes continuously
regardless of the humidity level immediately after
turning the power on.
Frequent use of exits and room
size/conditions may cause the humidity to not
reach the set level.
<To view set humidity level/ To set humidity level>
¡Pressing the button once displays the
set humidify level with the
indicator. After 3 seconds, the display
returns to the current humidity display.
¡Pressing HUMIDITY SELECTION while
is displayed sets the
humidity level. Each time the button is
pressed, the humidity setting changes.
<Modes>
¡Easy Dehumidifying The unit automatically controls airflow to counter excessive
room temperature/humidity. It activates the blower at high
temperatures.
50
020 3027
60
Humidity
level (%)
Room temperature (°C)
¡Room temperature is below 27°C - the unit
automatically sets the humidity level
according to the temperature.
¡
Room temperature is above 27°C - the unit lowers
the humidity level to 50%, then activates the blower.
The dehumidifier is reactivated when humidity rises
to 60%.
¡Easy Laundry The unit operates for 12 hours and automatically switches off.
∞
Empty the water tank before operating the unit. The unit may stop before the clothes are dry due to a full tank.
∞Do not use in conjunction with OFF Timer mode. The unit may stop before the clothes are dry.
∞The following conditions prevent clothes from drying well:
Room temperature below 15°C, large volume of laundry; laundry not spaced well; clothes of thick fabric
and spacious room.
∞When the room temperature is below 5°C, less water evaporates from the
clothes, decreasing the amount of temperature change. Therefore the unit is
unable to detect the state of the laundry and may turn off after 1 hour.
∞Restart the unit if it turns off before the laundry dries (except when the temperature is
below 5°C).
Information
Use standard
Effective
floor area ~ 12 m2
Use standard
Effective
floor area ~ 10 m2
Laundry
Up to
volume
approx. 4 kg.
¡Low
The unit continually operates the dehumidifier
regardless of current humidity.
¡Low Temp
The unit operates continuously automatically
controlling airflow according to room
temperature. The air flow is strongest below
15°C. The use of Low Temp mode is
recommended when the Low temperature
indicator is lit.
When the temperature is low,
condensation may still form on
windows exposed to the outside air even when
Low Temp mode is operating
Information
¡LAUNDRY
Continuous dehumidifying regardless of
current humidity at high airflow.
¡Air Purifier
Cleans the air by passing it through the air
filter.
The dehumidifying function is off.
Air passes through the air filter when the
dehumidifying function is on.
¡Mildew Guard The unit lowers room humidity levels once a day (for approximately 2-4
hours), suppressing mildew growth.
∞Refrain from turning on ventilation fans or opening windows or doors as this lowers performance.
∞Mildew growth may still occur due to the fungus type and conditions of the room.
E.g. Rooms that contain excessive condensation, bathrooms, and places with bad airflow
(insides of closets and behind furniture).
∞This mode does not remove existing mildew.
∞Do not use in conjunction with OFF Timer mode.
Information
ON 24 hours
24 hours
Dehumidifies Dehumidifies
Standby Standby
Use standard
Effective
floor area ~ 12 m2
¡Once every 24 hours the dehumidifier runs for 2
hours if the humidity is 40%, or 4 hours if at
50%. The unit operates intermittently,
automatically turning on and off according to
the humidity level of the room.
¡The unit continues operation if the humidity level
does not decrease.
Information
6570 505560
Press
SELECTION
SELECTION
E16S E16SX
E16S E16SX
E16S
E16S
E16SX
E16SX
E16S E16SX
E16SX

E16S E16SX
E16SX
E16S
6
Tank full lamp Defrosting lamp Defrosting indicator
<Indications>
High humidity warning
The unit automatically shuts down and indicates with the lamp and sound
that the water tank is full. Empty the water tank.
¡Tank full lamp lights
The unit beeps continuously.
¡Air flows stops (louvre stops)
¡Monitor turns off
•After removing the water and replacing the tank, the Tank full lamp will go
off, and the unit will automatically return to operation mode.
•When the Tank Full lights up, no operation but ON/OFF is possible.
The air flow (dehumidifier) is stopped when the lamp is lit. The frost
accumulated inside the unit is melted, and drained to the tank. After
defrosting is complete, the unit restarts.
¡
Defrosting lamp is lit
¡
Air flow is stopped
¡
Operating sound has changed
The unit automatically performs this function when the room temperature
falls below
15°C
.
(During peak periods, the unit will perform this function once every 40 minutes
for 5 to 10 minutes.)
When the room temperature falls below
15°C
while the unit is operating, the lamp turns on or the
indicator appears.
Cold lamp
<Viewing the Swing Monitor>
This indicates the range of louvre swing.
(The louvre and monitor do not move in synchronization.)
¡WIDE
To cover the entire
room.
¡REAR
With each press
of the button
¡
Stop swing
operation
¡The louvre stops in a
vertical position.
¡
The swing monitor turns
off.
¡UPWARD
For drying clothes, etc.
Swing speed is
automatically controlled to
send air to all corners of the
room.
Swings slowly to
send air further
To change the louvre
to a desired angle, wait
until the louvre stops,
then adjust by hand.
To set
1Open the louvre manually
2Switch the power on
3Select operating mode
Select desired operating mode
4Set operating time
¡One press - 2HR is
displayed
¡Each consecutive
press displays the
following setting
(2 ➝ 4 ➝ 8)
➝The OFF Timer is set
¡
OFF Timer lamp indicates remaining time
¡
Power automatically turns off at set time
Blank
Press
To cancel
<When you want to turn the unit off>
Press the Power button.
(Power off)
¡The OFF Timer is
cancelled
<When you want to disable the Timer
OFF mode, and continue operation>
Hold down the button until
the OFF Timer lamp goes
out. The unit returns to Low
mode
¡The OFF Timer is cancelled
Empty the water tank before operating. The unit
stops and the Tank full lamp lights if the tank
becomes full during operation.
Press
Press
Information
The indicator flashes when the humidity in
the room exceeds 75%.
Activating the dehumidifier is recommended
when the indicator is flashing.
If the High humidity warning is not used, remove the
power plug from the power socket.
E16SX Only
<Timer> E16S
For directing air
into a closet.
Low indicator

7
To set
1Switch the power on.
2Select operating mode.
Select desired operating mode.
3Change the louvre swing direction.
Select the desired setting.
4Set the operating time.
¡When pressed once the figure [ ] and [OFF] appear.
¡Each subsequent press changes the display in order from 1 to 9
hours. (Hold the button to run automatically through the numbers.)
➝The OFF timer is set.
The following is an example of a display indicating AUTO
dehumidifying (set to 60%), swing set to WIDE and the OFF timer set
for 2 hours.
¡The time remaining until the unit switches itself off is indicated in
increments of one hour with a flashing numeral.
¡When the set time is reached, the unit switches itself off and the
louvre closes automatically.
To set
1Switch the power off.
2Set the time you wish the unit to turn on.
¡Press once. The Power lamp, Mode indicator, and a [ ] on the
digital display flash. The [ON] indicator lights.
¡Each subsequent press changes the display in order from 1 to 9
hours. (Hold the button to run automatically through the numbers.)
3Select operating mode.
Select desired operating mode.
4Change the louvre swing direction.
Select the desired setting.
5Confirm the operating start time.
¡Power lamp and Time display light. ➝The ON timer is set.
The unit informs you if you forget to press the Power button by making the
Time display and Mode indicator blink and sounding an alarm for 1 minute.
The following is an example of a display indicating AUTO dehumidifying
(set to 60%), swing set to WIDE and the ON timer set for 5 hours.
¡The time remaining until the unit switches itself on is indicated in
increments of one hour with a flashing numeral.
¡When the set time is reached, the unit switches itself on.
To cancel
Press the Power button. (Power off)
¡The timer is cancelled.
The ON timer function is not operable using a commercially-available
timer plug outlet.
<<ON timer operation>>
The ON timer can be set for 1 to 9 hours.
Set the timer when the power is switched off.
No Display
(operation
is off)
Press
Press
Information
<<OFF timer operation>>
The OFF timer can be set for 1 to 9 hours.
Set the timer when the power is switched on.
No Display
(operation
is off)
To cancel
<When you want to turn the unit off>
Press the Power button. (Power off)
¡The OFF Timer is cancelled.
<When you want to disable the Timer OFF mode, and
continue operation>
Keep pressed until the remaining time display disappears. The unit returns
to Low mode.
¡The OFF Timer is cancelled.
∞The OFF timer and ON timer cannot be set at the same time.
∞Do not use the timer OFF mode in conjunction with Laundry or Midew
guard.
∞Empty the water tank before operating. The unit stops and the Tank
full lamp lights if the tank becomes full during operation.
Press
Press
Press
Press
Information
E16SX

8
<Using the Child Lock>
To Lock
¡The child lock indicator
The child lock is switched off when the power cord is unplugged.
When the child lock is activated the unit cannot be switched off or on. The
other switches are also inoperable until the child lock has been released.
¡If you lock the unit when the POWER is OFF.
The unit will not turn on, even if you press the POWER switch to turn it on.
Only the CHILD LOCK lamp will blink. (Press the POWER button once
again so that the lamp lights.)
¡If you lock the unit when the POWER switch is ON.
The unit will not turn off, even if you press the POWER switch to turn it off.
Only the CHILD LOCK lamp will blink. (Press the POWER button once
again so that the lamp lights.)
Press for 3 or more seconds.
Releasing the child lock
¡The child lock lamp goes out.
Press for 3 or more seconds.
4. Technical Points
4.1 The technical points of the new products
1) Powerful 16-liter/day humidifying *1
Quick relief from the damp and uncomfortable sensation caused by humidity. Mold and fungus can grow when
failing to dehumidify closets, dressing rooms, shoe cabinets and other spaces where humidity is prone to collect,
causing damage to the home and clothing. A single high-capacity unit is effective in dehumidifying and drying
various locations throughout the home, quickly moving from one point to the next. Mobilizing the 16-liter/day
dehumidifying power, rooms can be dried out in about 40 minutes.*2 Besides this, laundry drying takes about 120
minutes.*3 This is a caliber of speedy dehumidification available only with the 16-liter type.
1) Powerful 16-liter/day humidifying *1
Quick relief from the damp and uncomfortable sensation caused by humidity. Mold and fungus can grow when
failing to dehumidify closets, dressing rooms, shoe cabinets and other spaces where humidity is prone to collect,
causing damage to the home and clothing. A single high-capacity unit is effective in dehumidifying and drying
various locations throughout the home, quickly moving from one point to the next. Mobilizing the 16-liter/day
dehumidifying power, rooms can be dried out in about 40 minutes.*2 Besides this, laundry drying takes about 120
minutes.*3 This is a caliber of speedy dehumidification available only with the 16-liter type.
2) Keep your house fresh year-round with the highly rated “135° wide-angle louvre”
The ability to switch between the three settings of (1) REAR swing, (2) UPWARD swing and (3) WIDE swing makes it
possible to cope with different applications, for more effective dehumidifying than ever before.
(1)REAR swing ➝Effective for closets, shoe cabinets and around the kitchen.
(2)UPWARD swing ➝Effective for drying laundry, other uses. The swinging of the nozzle prevents uneven drying,
while speeding up the overall process. Laundry drying time is approx. 104 minutes.*3
(3)WIDE swing ➝Effective for quickly dehumidifying spacious room areas with the 135° wide-angle swing.
*1 Dehumidifying volume when operating for 24 hours at room temperature 30°C and relative humidity 80%.
*2 Test conditions: Room size 13m2, room temperature 25°C, time needed to reduce relative humidity from 90% to 60%.
*3 Humidifier laundry drying performance displays values measured by the autonomous standards of the Japan Electrical
Manufacturer’s Association (JEMA-HD090) established in February 2001.
Test conditions: Room size 10m2, room temperature 25°C, relative humidity 70%, laundry weight approx. 2kg (including 2 dress
shirts, 1 pair of pajamas, 3 T-shirts, 7 pairs of underwear, 3 face towels, 2 pairs of socks). Drying time will vary by the type of
building, other conditions.
E16S
E16SX
E16SX

9
Current Level of Humidity
The current humidity indicated by the dehumidifier may sometimes
differ from the humidity indicated by an ordinary hygrometer but this is
not a malfunction.
1. If the air temperature at the location where the dehumidifier is
installed and the place where the hygrometer is located differ, the
relative humidity will also differ.
2. The flow of air (ventilation) also affects the humidity, which may
differ for objects around the periphery and depending on the
installation location, etc.
This dehumidifier has no cooler function. In fact it emits
some heat causing the room temperature to rise by 2 to
4°C. The unit may produce warm air, but this is not due to
a malfunction.
The dehumidifier will not operate for 3 minutes when the
unit is turned on immediately after being turned off or
plugged in. (In order to protect the compressor.)
When dehumidifying begins, the operational noise
increases. This is not a malfunction.
The size of a room that can be dehumidified differs depending on the house structure and room style, etc.
Model MJ-E16S/E16SX-S1
~ 33m2
~ 51m2
~ 67m2
Room size guide
Single wooden dwelling
Japanese style room
Single prefab dwelling
Western style room
Group housing (concrete, lightweight concrete)
Western style room
What is relative humidity?
Relative humidity is the mass of
water vapor present in the air
expressed as a percentage of
the mass that would be present
in an equal volume of saturated
air (100%) at the same
temperature. The dehumidifier
and an ordinary hygrometer
indicate this relative humidity.
How does the dehumidifier work?
If you pour cold water into a cup, the air around it becomes cold, causing water
droplets to form on the surface of the cup. The dehumidifier takes advantage of this
phenomenon to remove moisture from the air.
1The unit draws air from the room,
cools it with its cooling coil, causing
the moisture to transform into water
droplets.
2The water droplets fall into the water
tank.
3The dehumidified air is reheated by
the heating coil, and then discharged.
The humidity of the room is thus reduced
by repeating steps 1, 2, and 3.
Working temperature
Wait for 3 minutes before dehumidifying
Room size guide
Defrosting
Heating during operation
4.2 Operation and Performance
Dehumidification is possible with a room temperature of 1
– 35°C. If the room temperature exceeds 35°C, however,
the temperature inside the unit will increase; therefore,
the protective device may activate and halt operation in
some cases. For this reason, the louvres should be aimed
upward.
•If the room temperature is lower than 1˚C, there is
danger of the removed water freezing, making
dehumidification impossible, so the fan will start
operating.
The unit may display during operation and stop air
flow, followed by a change in the operating noise. The
unit has stopped the airflow, and is melting internal frost
into the water tank. The unit will resume automatically
when the defrost operation completes.
This operation will be performed automatically when
the room temperature is approximately 15°C or
lower. (When humidity is high, this will occur
approximately once every 40 minutes for 5 – 10
minutes.
q
w
e
Re-heating
coil
Cooling coil
Moist air
Compressor
Dried (warm) air
Water tank

10
4.3 Coolant Circuit
Dehumidifying
Defrosting
Coolant flow
Blow
Fan
Heat exchanger
(heat radiation)
Heat exchanger
(cooling)
φ
6.35
φ
5
Capillary tube
Capillary tube
φ
2.0
× φ
0.8
×
340
φ
5.0
× φ
4.0
φ
6.35
φ
6.35
φ
5
φ5
Intake
φ
6.35
Tube temperature
sensing thermistor
Compressor
Humidity
sensor
Room
temperature
sensing thermistor
Solenoid
valve
(closed when
dehumidifying
and open when
defrosting)
4.4 Performance curve
Relationship between dehumidification and room temperature/humidity
The lower the temperature and humidity, the smaller the quantity of dehumidifying as shown on the graph.
•The dehumidification quantities shown on the graph were measured at constant temperature and humidity, and do
not reflect actual usage conditions.
•In winter, the air is so dry that dehumidification is almost impossible.
•Operation in low temperatures
Operating the LOW TEMPERATURE mode produces greater dehumidification than when on HIGH for
days when the temperature is low, but humidity is high due to snow or rain.
0
2
4
6
8
12
14
16
10
510152025
30
( )
( )
in case of
80% humidity
Dehumidification capacity (L/day)
in case of
60% humidity
Room temperature (°C)
LOW TEM Mode
High Mode

11
3Clean air filter
Hose with lukewarm water when
excessively soiled. Dry well.
4Set the air-purifying filter
Set the air-purifying filter into the air
filter with the honeycomb side up.
5
Attach the air filter and front panel
1Remove front panel and air filter
2Remove the air-purifying filter
The air purifying filter cannot be washed
in water.
Replace the air purifying filter when it
becomes dirty.
Removing Water from the Tank
The unit automatically shuts down and lights the Tank
full lamp when the tank (approximately 4L) is full.
Empty the tank.
1Remove the water tank.
2Remove the tank lid, and empty.
3Reattach the tank lid and replace
the water tank.
Confirm that the lid is
securely attached to the
water tank, and push the
tank in. Close the front
door.
¡If the lid is not properly closed, you may have
problems removing the tank.
¡If the tank is not installed correctly, the tank
full light will come on, and the unit will not
operate.
Do not remove or dismantle the floating element
in the tank. If it is removed, the unit cannot detect
when the tank is full, and this could result in
leakage.
Replacing the Air Purifying Filter
The air purifying filter is disposable.
The air purifying filter is disposable.
Make sure to replace the filter when it becomes dirty.
(The filter cannot be washed or reused.)
Replacing air purifying filter
For maintenance procedures see p10.
1Remove front panel and air filter
2Replace air-purifying filter
3Attach air filter and front panel
Note
Maintenance
Do not use detergents, cleaning agents for heat exchange equipment, abrasive powders, chemically treated
dusters, gasoline, benzene, thinners or other solvents, as they can damage the unit or the water tank, which may
result in leakage.
Cleaning
Once every two weeks
Water tank
Wipe with a soft cloth.
Main unit
Wipe with a
soft cloth.
The unit draws in dust present
in the air, and this may cause
the tank to gradually become
dirty. If the dirt does not come
off easily, wash with cold or
warm water, then wipe with a
soft, dry cloth.
Floating
element
Do not remove
or dismantle.
5. Daily checks and maintenance
Air filter
Debris clogging the air filter reduces the effectiveness of the dehumidifier.
Clean once every 2 weeks.
Air filter Air purifying filter for replacement
∞Type: MJPR-SXFT
∞Type code: 5C5 813
For these items contact your nearest Mitsubishi
Electric dealer.
Front
panel
1Remove holding
the bottom
2Remove
holding the
tabs
Air filter
Air purifying filter
Run a vacuum cleaner
lightly over the air filter
surface to remove the
dirt.
If the metal fin inside the main unit is slightly
bent, the unit’s performance is not affected.
Honeycomb
side
1Attach holding the
tabs.
2Hook the top edge to
the top part of the unit
and push the bottom in.
Open the front door Grasp handle and slide out
Float
Do not remove
<Hold the tank this way.>
water tank
Pour the
water out as
shown.
Parts sold separately
When to replace it
Replace the filter when it becomes dirty
(brownish) with cigarette smoke, dust, etc.
Generally, one filter should last about 6 months.
(This will depend on usage conditions.)

12
6. Wiring Diagram and Block Diagram
6.1 Wiring Diagram
(1) Current fuse ....................Overcurrent flow caused by deterioration in electrical parts or other problems
turns the power source to OFF.
<Current setting: 2A>
(2) Motor protector................Current flow exceeding 1.7A with compressor surface temperature of approx.
(Overload relay)..............100°C shuts down compressor operation.
The compressor will also shut down when malfunctions or other problems
cause the current flow to exceed 4.7A.
(3) Control circuitry ...............The room temperature thermister senses temperature below about 0°C, and
shuts down the compressor.
(4) Thermal fuse ...................When blower motor temperature exceeds 134°C due to blower locking or other
malfunctions, blower operation shuts down.
Safety Devices
P1 P11
P20
P100
P2 P3P5
P4
FM
S
C
R
CM
P200
P10
P13
SV
P201
P
101
SM
White
White
White
White
Brown
Brown
Thermistor (Tube
temperature sensing)
1°C (defrost)/12°C (end)
Sensors
(Humidity and room
temperature sensing)
Power supply board
Blue
Brown
Gray
Gray
Gray
Gray
Blue
Blue
Blue
Black
Gray
White
Red
Yellow
Control board
Tank full switch
Power plug
Stepping motor
Run capacitor
Overload relay
Compressor
Solenoid valve
Fan motor
E16S
E16SX
P1
P11
P10
P100
P2 P3P5
P4
FM
S
C
R
CM
P200
P13
SV
White
White
White
White
Brown
Brown
Thermistor (Tube
temperature sensing)
1°C (defrost)/12°C (end)
Sensors
(Humidity and room
temperature sensing)
Power supply board
Gray
Gray
Gray
Gray
Blue
Black
Gray
White
Red
Yellow
Control board
Tank full switch
Power plug
Run capacitor
Overload relay
Compressor
Solenoid valve
Fan motor
Blue
Brown
Blue
Blue

13
Closed
OFF ON OFF ON OFF
OFF
OFF OFF
ON
OFF OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
Closed
AUTO
Low
Temp
Mildew
guard
OFF
OFF
OFF
Closed
On On
Child lock
Off
Note : Display lamp/Operable
: Timer – flashes when on
: Off/stopped/inoperable
: Operable only when swing on/lit
: Operable only when swing on and blower fan rotates
Power
Easy selection mode
Tank full
Humidity (set/current)
Operation mode
Swing
On/off timer
Mildew/guard
Defrost
Low temp
Child lock
Operation
Auto
Operation switch
Selection
Swing louvre
On/off timer
Child lock
LCD indicator
LED indicator
Switch
Compressor
Blower
Solenoid valve
Swing louvre
Operation off
Auto
OFF
Mildew
guard
Low Temp
Laundry
OFF
Easy
dehumidifying
Tank full
Defrost
Off timer on
On timer
being set
On timer
counting
: Only lit (only displays swing range)
: LCD lights at each operation mode
: LCD flashes at each operation mode
: Lights at room temperatures of 14°C or under
: Varies by conditions.
OFF
LOW
LOW
Operation mode
Dehumidifying operation
6.2 Function List
E16S
E16SX
※= Lit. = Can light. = Not lit.
Blower
Indicator
Operation off
Off timer
Air purifier
Defrost
Laundry
Low temp
One item is
Low
Easy
Dehumidifying
Low temp
Easy dehumidifying
Laundry
Air purifier
Off timer
Tank full
Low temperture
Defrost
Low
OFF
OFF
OFF
OFF
OFF
Operation mode
OFF ON
ON
ON
ON
ON
ON
ON
ON ONOFF ON/
OFF
ON/
OFF
OFF OFF OFF OFF OFF OFF
OFF
OFF
OFF
Tank full
Compressor
Solenoid value
Dehumidifying operation

* Rank 1=Lb, Rank 2=La, Rank 3=Mi, Rank 4=Hi, Rank 5=HH, Rank 6=SH
4Mildew Guard mode
(a) Alternately activates/deactivates compressor or blower according to current humidity/time. (Fan rank is as shown in 2)
(b) Operates dehumidifier when Mildew guard mode is activated or every 24 hours after activation.
(c) Dehumidifier is deactivated when the following parameters are breached. (Compressor and blower stop)
•2hours of below 40% elapses and below 35% is detected.
•4hours of below 50% elapses and below 45% is detected.
*However, if the humidity rises above the given levels for more than 3 minutes, the accumulated time returns to zero.
(d) If the humidity rises to 75% after deactivation, the dehumidifier automatically operates until the humidity is brought down to 65%.
(e) If 24 hours elapse from the time the unit was turned on, all accumulated time counts for all humidity levels are reset.
2HR 2HR
4HR4HR
45%
Elapsed time
35%
Elapsed time
Humidity level
Compressor
Blower
Mildew
Guard
ON
Below 45%
time count
start
Below 35%
time count
start
Below 35%
time count
stop
Dehumidifier
activated
Below 35%
time count
start
Dehumidifier
deactivated
Dehumidifier
deactivated
Dehumidifier
deactivated
Accumulated
time counts
reset
65%
45%
40%
35%
24HR
75%
ON
OFF
Below
45%
Below
35%
3 minutes
above 40%
elapse
Limit
75%
Limit
recovered 65%
14
<Operation Control>
1Humidity set operation
(a) Compressor and blower fan operation will switch by current humidity and set temperature.
2Specifications shared at all operation modes
(a) Dehumidifying will not start for about 2 seconds when turning the operation power on with the swing stopped. (However, humidifying
will begin immediately when pressing the swing louvre switch within 2 seconds of turning the power on.)
(b) The compressor and blower fan will operate for about 7 minutes after turning on the operation switch or activating the compressor,
regardless of humidity or temperature levels.
3Low, Low Temp, Mildew Guard, Air Purifier, Laundry
Compressor
ON Rank 1
Rank 1 Rank 2
Rank 2 Rank 5
Rank 5
Stopped
Stopped
Stopped
27°C34°C
29°C36°C
ON
OFF
Current humidity
– Set humidity
Decline in
current
humidity
+3%
–1%
+5%
+1%
Rise in current
humidity
Blower fan rank
Mildew Guard E16SX only
Low
Air Purifier E16S only
Low Temp
Laundry E16S only
Laundry E16SX only
ON ON
ON
ON
–
–
–
–
–
–
–
–
–
–
–
–
–
––
–––
––
ON
ON
Compressor
OFF
ON
Rank 1 Rank 1 Rank 1 Rank 1
Rank 1 Rank 1
Rank 1Rank 1
Rank 6
Rank 2 Rank 2
Rank 2 Rank 2 Rank 5
Rank 5
Rank 5
E16S
E16S
E16SX E16SX E16SX E16SX E16SX
E16S E16S E16S
Rank 5
Rank 5
Rank 5
Rank 5
Rank 2
Rank 2 Rank 2
Rank 2
Rank 2
Rank 3 Rank 4 Rank 4
Rank 4 Rank 4
Rank 3
Rank 6
14°C
27
°C
34
°C
16°C 29°C
Blower fan rank
36°C
E16SX
E16SX
E16SX
E16S E16SX

15
5Easy Dehumidifier
(a) Modifies humidity setting or operates CIRCULATE mode (blower only mode) according to the room temperature.
(b) Switches temperature table every 60 seconds to prevent the blower from turning on and off at the 3-minute restart for the coloured
section in the chart below. (51% – 59%)
(c) When the room temperature is above 29°C (temperature rising) or 27°C (temperature decreasing), CIRCULATE mode operates with the
humidity below 50%. The unit activates the dehumidifier when the humidity rises above 60%, and returns to CIRCULATE mode when
the humidity drops below 50%.
0
60%
ON
ON
OFF OFF OFF OFF
ON
ON
60% 60%50% 50%
50%
12 3
Current humidity
– Set humidity
20°C 27°C 34°C
+3%
–1%
+5%
+1%
Temperature
Temperature table
Set humidity
Fan rank
Compressor
Fan rank
Compressor
Fan rank
Compressor
22°C 29°C 36°C
Rank 1
Rank 1
ON
ON
Stop
Rank 1
Rank 1
Rank 2
Rank 2
ON
ON
Stop
Circulate
To
Dehumidifier
mode
To
Dehumidifier
mode
Rank 4 Rank 5
To
Circulate
mode
Rank 5
Rank 5
To
Circulate
mode
Dehumidifier mode
Circulate
Dehumidifier mode
Circulate
set humidity 60% Dehumidifier mode
set humidity 50% Circulate
set humidity 60%
Set humidity 60% Set humidity 50%
ON
OFF
ON
OFF
50%
60%
Humidity
Compressor
Blower
~20°C~ ~27°C~Temperature
E16S E16SX

16
6.3 Timing Charts
E16S
Operation mode
OFF
SH
LO
60%
Tank full/ Power OFF
Hi
Mi
Power
ON
Mode button
ON
Easy
ON
ON
OFF
Operation switch
Easy
dehumidifying
Easy
dehumidifying
ON
OFF
Compressor
ON
OFF
Float switch
Auto
Blower fan
Tank full Drain Power
OFF
Humidify
Easy dehumidifying/ Mode
max
3 min.
3
sec.
Mi for 2 sec.
at start-up.
min
7 min.
Auto
※When room temperature is
between 20℃and 27℃.
ON
OFF
Tank full light
Auto
50%
Low temp
Room
temperature
Low temp
Decrease in room
temperature
14℃
16℃
Increase in room
temperature
3
sec.

17
E16S
12℃
Off timer
0℃
Defrost count
start
ON
OFF
Timer button
ON
OFF
Compressor
ON
OFF
Solenoid valve
Tube
temperature
Defrost
ON
OFF
Blower fan
40
min.
ON
OFF
Operation switch
2hr 4hr 4hr
After 4 hr.
Defrost
start
Defrost
finish
ON
OFF
Timer lamp
ON
OFF
Mode lamp
2hr
After 1 hr. After 2 hr.
Off timer
ON
Off timer
ON
Off timer
ON
8hr
4 hr. 2 hr. 2 hr.

18
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
60%
59%
61%
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
0°C
12°C
ON
OFF
ON
OFF
Operation
ON
Operation
OFF
Operation
switch
Dehumidifying
stop
Dehumidifying
start
Humidity
set
Selection
switch
Selection
switch
Operation
switch
Operation
switch
AUTO (60%) AUTO (60%)
LOW
Wait 3 seconds Wait 3 seconds
EASY
DEHUMIDIFYING
LAUNDRY
MILDEW
GUARD
LOW
TEMP
Operation start/Mode switch/Operation stop
Operation switch
Mode display
Compressor
Blower fan
Solenoid valve
Float switch
Tank full light
Humidity
Tube temperature
High Humidity
Warning
Low temperature
Louvre
Swing
off
Swing
on
Louvre indicator
(“swing on” only)
Audible alarm
Closed Closed
Closed
Stopped
at 90°
Lights only with a room temperature of 14°C or less
Max 3 min. Min 7 min.
E16SX

19
Defrost count
start
Defrost operation
start
Defrost
operation stop
Tank full
detection
Tank empty
detection
Swing mode
switch
Operation
OFF
Humidity
rise
Humidity
decline
Lights only with a room temperature of 14°C or less
40 min. elapsed
Defrost operation/Tank full detection/Swing mode change/Mildew & mite display
Weak alert
tone
Closed
Closed
Lights only with a room temperature
of 14°C or less
Lit
Swing mode change
Swing mode display change
Wait 3
seconds
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
75%
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
0°C
12°C
ON
OFF
ON
OFF
Operation switch
Mode display
Compressor
Blower fan
Solenoid valve
Float switch
Tank full light
Humidity
Tube temperature
High Humidity
Warning
Low temperature
Louvre
Swing
off
Swing
on
Louvre indicator
(“swing on” only)
Audible alarm
E16SX

20
On/off timer operation
Stopped at 90°
Lights only with a room temperature of 14°C or less
Swing mode displayArea indication only
Closed
Closed
On timer
ON
1 hour
elapsed
Off timer
ON
On timer
ON
Operation ON
(Set to 2 hours)
2 hour
elapsed
Off timer
ON
1 hour
elapsed
2 hour
elapsed
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
75%
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
0°C
12°C
ON
OFF
ON
OFF
Operation switch
Mode display
Compressor
Blower fan
Solenoid valve
Float switch
Tank full light
Humidity
Tube temperature
High Humidity
Warning
Low temperature
Louvre
Swing
off
Swing
on
Louvre indicator
(“swing on” only)
Audible alarm
E16SX
This manual suits for next models
1
Table of contents
Other Mitsubishi Dehumidifier manuals

Mitsubishi
Mitsubishi MDC20W-H User manual

Mitsubishi
Mitsubishi DA25W-H User manual

Mitsubishi
Mitsubishi MJ-E26VX-A1 User manual

Mitsubishi
Mitsubishi MJ-E14CG-S1-IT User manual

Mitsubishi
Mitsubishi MJ-E16V-S1 User manual

Mitsubishi
Mitsubishi MJ-EZ6CX-S1-IT User manual

Mitsubishi
Mitsubishi MJ-E16VX-S1 User manual

Mitsubishi
Mitsubishi DB23W-H User manual