GENERAL INSTRUCTIONS
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring
Regulations (BS7671) and current Building Regulations. If in any doubt, consult a
qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this product is fitted) does not exceed
the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location
for installation
• Do not overload this accessory or subject it to conditions outside its rating
• This product is Class I and must be earthed
• This product is IP66 rated

INSTALLATION
Please note: the unit should be fixed to a rigid flat surface as unevenness could cause
damage to the product or affect operation
• Provide power to the required point of installation (refer to BS7671 for correct cabling
methods)
• Remove the front assembly from the backbox and carefully lift off the gasket. Drill the
required number of fixing holes in the backbox (see Fig. 1)
• Using the backbox as a template, mark the location for, and drill the fixing holes ensuring
not to infringe with any gas/water pipes or electrical cables. The backbox can be rotated
through 180°if required, to position the two cable entries on the top
Fig. 1
INSTALLATION & MAINTENANCE MANUAL
ICONS: 230V, Class I, IP66
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
OP7N / OP9N
SAFETY
•This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•Please isolate mains prior to installation or maintenance
•Check the total load on the circuit (including when this product is fitted) does not exceed the rating of
the circuit cable, fuse or circuit breaker
•Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•Do not overload this accessory or subject it to conditions outside its rating
•This product is Class I and must be earthed
•This product is IP66 rated
INSTALLATION
Please note: the unit should be fixed to a rigid flat surface as unevenness could cause damage to the product or
affect operation
•Provide power to the required point of installation (refer to BS7671 for correct cabling methods)
•Remove the front assembly from the backbox and carefully lift off the gasket. Drill the required number
of fixing holes in the backbox (see Fig. 1)
•Using the backbox as a template, mark the location for, and drill the fixing holes ensuring not to
infringe with any gas/water pipes or electrical cables. The backbox can be rotated through 1800, if
required, to position the two cable entries on the top
Fig. 1
•The backbox has drain hole drilling guides marked (see Fig. 2). Drilling a drain hole is advised if the
unit is installed in a location subject to temperature fluctuations where build-up of condensation may
occur. It is not advised if the unit will be subject to high pressure jets, as drilling a drain hole will reduce
the IP rating. A 3-5mm hole should be drilled at the bottom back edge of the enclosure where marked.
If wiring in conduit to the bottom entry, then the drain hole should be drilled at the lowest point of the
conduit run not in the backbox

The backbox has drain hole drilling guides marked (see Fig. 2). Drilling a drain hole is
advised if the unit is installed in a location subject to temperature fluctuations where
build-up of condensation may occur. It is not advised if the unit will be subject to spray
or jets, as drilling a drain hole will reduce the IP rating. A 3-5mm hole can be drilled at
the bottom back edge of the enclosure where marked. If wiring in conduit to the bottom
entry, then the drain hole should be drilled at the lowest point of the conduit run not in the
backbox
Fig. 2
Fig. 2 (OP7N shown)
•Remove one or more of the pre-fitted blank plugs as required by pushing out from the inside and install
a suitable IP rated gland or adaptor (not supplied). For rear entry, cut or drill a 20/25mm hole where
marked and install a suitable IP rated grommet (not supplied). Unused cable entries must have the
blank plugs fitted
•Feed the mains cable into the unit and secure the base plate to the surface. The fixing holes are
slotted to allow some rotational adjustment
•Replace the gasket onto the backbox, then wire as shown in Fig. 3 ensuring that correct polarity is
observed: L - Live (brown), E - Earth (green/yellow), N - Neutral (blue)
Fig. 3 OP7N OP9N
•An earth connection must be made to the earth terminal of the socket. Use green/yellow sleeving on
earth conductors that are not insulated. The earth terminal in the backbox is provided for convenience
and does not need to be connected
•Check all electrical connections are secure with no loose strands of cable
•Ensuring the gasket does not become damaged or pinched, fit the socket assembly onto the backbox,
taking care not to compress, damage or trap any cables, and secure with the screws provided - do not
overtighten
•Fit screw covers
•Switch on and check for correct operation
For security, and to prevent unwanted tampering with the product, a lug feature with a 6mm hole is provided to
accept a padlock or similar locking security device (see Fig. 4).

Fig. 2 (OP7N shown)
•Remove one or more of the pre-fitted blank plugs as required by pushing out from the inside and install
a suitable IP rated gland or adaptor (not supplied). For rear entry, cut or drill a 20/25mm hole where
marked and install a suitable IP rated grommet (not supplied). Unused cable entries must have the
blank plugs fitted
•Feed the mains cable into the unit and secure the base plate to the surface. The fixing holes are
slotted to allow some rotational adjustment
•Replace the gasket onto the backbox, then wire as shown in Fig. 3 ensuring that correct polarity is
observed: L - Live (brown), E - Earth (green/yellow), N - Neutral (blue)
Fig. 3 OP7N OP9N
•An earth connection must be made to the earth terminal of the socket. Use green/yellow sleeving on
earth conductors that are not insulated. The earth terminal in the backbox is provided for convenience
and does not need to be connected
•Check all electrical connections are secure with no loose strands of cable
•Ensuring the gasket does not become damaged or pinched, fit the socket assembly onto the backbox,
taking care not to compress, damage or trap any cables, and secure with the screws provided - do not
overtighten
•Fit screw covers
•Switch on and check for correct operation
For security, and to prevent unwanted tampering with the product, a lug feature with a 6mm hole is provided to
accept a padlock or similar locking security device (see Fig. 4).
• Remove one or more of the pre-fitted blank plugs as required by pushing out from the
inside and install a suitable IP rated gland or adaptor (not supplied). For rear entry, cut or
drill a 20/25mm hole where marked and install a suitable IP rated grommet (not supplied).
Unused cable entries must have the blank plugs fitted
• Feed the mains cable into the unit and secure the base plate to the surface. The fixing holes
are slotted to allow some rotational adjustment
• Replace the gasket onto the backbox, then wire as shown in Fig. 3 ensuring the correct
polarity is observed: L - Live (brown), E - Earth (green/yellow), N - Neutral (blue)
Fig. 3
OP7N OP9N

Fig. 4
Note: The LED indicator is lit when there is power to the unit, the fuse is in good condition and the switch (if
present) is on, irrespective of whether a load is connected or not
WARNING
To ensure continued safe and proper weatherproof operation, the unit must not be left with the cover raised
open or the catch left unlocked.
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist.
Clean the external surfaces, the cover securely closed, with a damp cloth using a mild solution of detergent and
warm water only, do not use aggressive cleaning products or solvents which may damage the product. If it is
necessary to clean inside the cover, use a soft dry cloth only.
Do not use any source of high-pressure washers to maintain or clean this product.
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period it should be returned to the place of
purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
DCMAY20_V2
Fig. 4
• An earth connection must be made to the earth terminal of the socket. Use green/yellow
sleeving on earth conductors that are not insulated. The earth terminal in the backbox is
provided for convenience and does not need to be connected
• Check all electrical connections are secure with no loose strands of cable
• Ensuring the gasket does not become damaged or pinched, fit the socket assembly onto the
backbox, taking care not to compress, damage or trap any cables, and secure with the
screws provided - do not overtighten
• Fit screw covers
• Switch on and check for correct operation
For security, and to prevent unwanted tampering with the product, a lug feature with a 6mm
hole is provided to accept a padlock or similar locking security device (see Fig. 4).

GENERAL
This product should be recycled in the correct manner when it reaches the end of its life.
Check local authorities for where facilities exist.
To clean the external surfaces, securely close the cover and use a damp cloth with a mild
solution of detergent and warm water only, do not use aggressive cleaning products or
solvents which may damage the product. If it is necessary to clean inside the cover, use a
soft dry cloth only.
Do not use any source of high-pressure washers to maintain or clean this product.
WARNING
To ensure continued safe and proper weatherproof operation, the unit must not be left with
the cover raised open or the catch left unlocked.
Irreparable damage will occur if this instruction is not followed.
Note: The Power Indicator is lit when there is power to the unit and the switch is on,
irrespective of whether a load is plugged in or not

ML Accessories Limited LU5 4LT
www.mlaccessories.co.uk
DCMAY20_V2
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install this product
in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper
use, or removal of the batch code will invalidate the warranty. If this product should fail
within its warranty period it should be returned to the place of purchase for a free of
charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML
Accessories reserve the right to alter product specification without prior notice.
ACCESSORIES LTD ACCESSORIES LTD
ACCESSORIES LTD
ACCESSORIES LTD
11
IP
66
This manual suits for next models
1
Table of contents
Other ML Accessories Accessories manuals

ML Accessories
ML Accessories OP9RCD Instruction Manual

ML Accessories
ML Accessories Knightsbridge SK005A Instruction Manual

ML Accessories
ML Accessories Knightsbridge OS008 Instruction Manual

ML Accessories
ML Accessories OSPIRKW User manual

ML Accessories
ML Accessories Knightsbridge OS0014 Instruction Manual

ML Accessories
ML Accessories OS009 Instruction Manual

ML Accessories
ML Accessories Knightsbridge SK005A Instruction Manual