manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Modulex
  6. •
  7. Light Fixture
  8. •
  9. Modulex MMP-100D/SH User manual

Modulex MMP-100D/SH User manual

This manual suits for next models

6

Other Modulex Light Fixture manuals

Modulex LINEAR100 User manual

Modulex

Modulex LINEAR100 User manual

Modulex MMP-060S Series User manual

Modulex

Modulex MMP-060S Series User manual

Modulex MMP-130S User manual

Modulex

Modulex MMP-130S User manual

Modulex MMP-080A/10B/Z1/2 User manual

Modulex

Modulex MMP-080A/10B/Z1/2 User manual

Modulex MMP-130S/5H User manual

Modulex

Modulex MMP-130S/5H User manual

Modulex UB9451D/1.2/RB User manual

Modulex

Modulex UB9451D/1.2/RB User manual

Modulex MPP-10/0300/COS/S User manual

Modulex

Modulex MPP-10/0300/COS/S User manual

Modulex MMP-080W/FLF User manual

Modulex

Modulex MMP-080W/FLF User manual

Modulex SX-B9451D/CE User manual

Modulex

Modulex SX-B9451D/CE User manual

Modulex MSP-100S Series User manual

Modulex

Modulex MSP-100S Series User manual

Modulex MMP-130S/1H User manual

Modulex

Modulex MMP-130S/1H User manual

Modulex MMP-130A/40BZ1/2 User manual

Modulex

Modulex MMP-130A/40BZ1/2 User manual

Modulex MMP-080S/5H/1E/10B/Z2/2 User manual

Modulex

Modulex MMP-080S/5H/1E/10B/Z2/2 User manual

Modulex MMP-080A/10B User manual

Modulex

Modulex MMP-080A/10B User manual

Modulex MSP-080A/10B/DL/3 User manual

Modulex

Modulex MSP-080A/10B/DL/3 User manual

Modulex MMP-080W/20B/Z1/2 User manual

Modulex

Modulex MMP-080W/20B/Z1/2 User manual

Modulex MMP-080S User manual

Modulex

Modulex MMP-080S User manual

Modulex MPP-10/0300/F/R User manual

Modulex

Modulex MPP-10/0300/F/R User manual

Modulex MMP-060S Series User manual

Modulex

Modulex MMP-060S Series User manual

Modulex LINEAR150 User manual

Modulex

Modulex LINEAR150 User manual

Modulex MMT-101/TLF/01 User manual

Modulex

Modulex MMT-101/TLF/01 User manual

Modulex MMP-080F User manual

Modulex

Modulex MMP-080F User manual

Modulex MSP-080F/FLF/20B/DL/3 User manual

Modulex

Modulex MSP-080F/FLF/20B/DL/3 User manual

Modulex SX-B9351D User manual

Modulex

Modulex SX-B9351D User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Lightolier LP200 specification

Lightolier

Lightolier LP200 specification

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier Lytespan 83ED17S specification

Lightolier

Lightolier Lytespan 83ED17S specification

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.


Thefixtureisforindooruseonlyingeneralconditions.
Cannotbeusedfollowingconditions(Causesoffalling,electrocutionandfire)
 
●Ambienttemperatureunder0℃andover35℃
●Highhumidity
●Outside
●Onthefloor
●Insulatedinsideofceiling
●Vibratedorshockedareas
●Areasgetdirectsunlight
●Inclined,unevensurface
●
Ceilingwhichcanʼtholdthefixtureweight
●Onthewall
●
Placesaffectedbywindorair-conditionermachine
●Nearfire
●
Dustyareas,corrosivegasoutbreaksareas
Before
installation
Forelectric
wiring
Atlighting
fixture
installation
Warning
Warning
Warning
Warning: Failuretoinstallthefixtureproperlycouldresultinpersonalinjury.
Failuretoinstallthefixtureproperlycouldresultinpropertydamage.
:Prohibited
:Strictobservance
Caution:
Caution
Caution
Toinstallthefixturesafely《Readcarefullyandfollowalltheinstructionsintheguide》
Pleasefollowthefixturesʼindicationorspecificationforthedistanceofirradiatedarea.
(Causesofchangeinshape,changeincolorofirradiatedobjects)
Pleasecontactifyouarenotabletojudgewhetherinstallation
environmentissuitabletotheplacesornot.
Onlyqualifiedpersonmayworkonelectricwiringandequipment.(Causeofaccidents)
Besurepowersupplyvoltageiswithin±6%mentionedinratingplateortheguide.(Causesofshortlifeoflamps・electrification・fire)
Besureallthewiresandcodesarenotdamaged.(Causesoffalling・damage)
Pleasefollowthefixturesʼinstructionorthisguidetoinstallthefixtureandlamp.(Causesoffalling・electrification・fire)
Switchoffthepowerwheninstallingthelamp.(Causesofelectrification)
Donottouchthefixturewhenswitchisonorjustturnofftheswitchbecauseofhightemperature.
Donotputorcoverthefixturebyanycloths,papers,orinsulators.(Causesofnotlighting・fire)
Donotplaceanymetallicorflammableobjects.(Causeofelectrification・fire・brokenfixture)
Makesuretoinstallallthepartsoffixturesbesidesinstallationandmountingpartswillnottouchwithany
objectsbothinsideandoutsideofceilingsuchaslightingtrack,etc.(Causesoffalling・electrification・fire)
Donotdismountorremodelfixtures.(Causeofelectrification・fire・falling・brokenfixtures)
Donotoperatewithwethands.
Ifyousmellsmoke,seesmoke,orfindanythingunusual,pleaseturntheswitchoffandaskconstruction
companiestorepair.(Causeofelectrification・fire)
Makesuretheconstructionwillnotaffectanyfirepreventionsystemssuchassprinklerbyheatfromthefixture.
(Causesforimproperoperation)
Usealternatingcurrent.Pleasefollowratingplateoffixturesforpowersupplyfrequency.
(Causeofelectrification・fire)(50Hz・60Hzcommonuseforballastsandincandescentlampfixtures)
MMP-100D/SH/WCL・MCL・SCL/30B/DL/3
PICKUPDOWNLIGHT
InstallationGuideLightingFixture
InstallationGuide LightingFixture
20cm〜
10cm〜
Insulator
InsulatorInsulator
Φ100
Ceilingcutout
0.68k
10°
90°
g
Weight
Rotatedegrees
Lamp COB
inputvoltage
inputcurrent
37.9V
0.9AMAX
Driver
Soldseparately
Pleaseuseconstantcurrentdriver.
Thisfixturecanonlybeinstalledonahorizontalceiling.
LightingFixture
ToinstallModuleXsafety
PICKUPDOWNLIHGHT
InstallationGuide
InstallationDetails InstallationDiagram Caution
Thedescriptionofapowersupply.
Installationtoceiling ki
k
Installthefixturetothemounting
frame.
Installthesafetywiretothe
mountingframe.
Makesuretoinstallthesafetywire
tothemountingframesecurely.
Makesurethefixturewillnottouch
anyobjectsinceiling.
1
2
i
Usecleansoftclothtocleanupand
maintaininnersideofthebody.
Safetywire
Mountingframe
Inside
Cleangloves
1
2
Safetywire
Ceiling
Mountingframe
Wiringconnection
Pleaseconnectaccordingto
thedescriptionofapowersupply.
Wiringdiagram
PE
PE
L
L +
+RED
-BLACK
-
N
N
LED
Driver
Whenconnectingthedriver,
carefulattentionshouldbe
paidtoconnecting+and−.
Metalpartinacablepoint,
pleasedon'ttouchwithbare
handdirectly. CAUTION!
Donotreversepolarity!
−BLACK
+RED
Body
MMP-100D/SH/WCL・MCL・SCL/DL/3
InstallationDetails InstallationDiagram Caution
1
2
Body
Hood
3
1
2
3
4
5
Pulloutthebodyfromthehood.
Putafilterinhood.
Turnaroundtheoptionholder,
andputin.
Pleaseattentionthat
Donʼtputinthefiltersthan
therulenumberofpieces.
Causesoffallinganddamage.
thesharpenerlensiscounted
twopiecesoffilterlenses.
Turnaroundthehood.
Turnaroundtheoptionholder,
andputout.
f
Optionalpartsinstallation f
d
Slidethehood.
OPTION
HOLDER
FILTER Sharpner
lends
Sharpner
lends
UPto3FILTERS
OPTION
HOLDER
Matchthemark.
Then,pushthehoodandslide
it,inordertolockthebody.
(topreventfromfalling)
d
Matchthemark.
DC900mAMAX
37.7V
5/F,LongbowHouse,14-20ChiswellStreet,London,EC1Y4TW,UK
Tel:+44-01273-616649
ConcordLighting
(Contact) (Manufacturer)
ModuleXInc.
#21AraiBldg,1-20-6Ebisu-MinamiShibuya-ku,Tokyo
Tel:+81-3-5768-3131