Modulex MPP-10/0300/F/R User manual

InstallationGuideLightingFixture
Thefixtureisforindooruseonlyingeneralconditions.
Cannotbeusedfollowingconditions(Causesoffalling,electrocutionandfire)
 
●Ambienttemperatureunder0℃andover35℃
●Highhumidity
●Outside
●Onthefloor
●Insulatedinsideofceiling
●Vibratedorshockedareas
●Areasgetdirectsunlight
●Inclined,unevensurface
●
Ceilingwhichcanʼtholdthefixtureweight
●Onthewall
●
Placesaffectedbywindorair-conditionermachine
●Nearfire
●
Dustyareas,corrosivegasoutbreaksareas
Before
installation
Forelectric
wiring
Atlighting
fixture
installation
Warning
Warning
Warning
Warning: Failuretoinstallthefixtureproperlycouldresultinpersonalinjury.
Failuretoinstallthefixtureproperlycouldresultinpropertydamage.
:Prohibited
:Strictobservance
Caution:
Caution
Caution
Toinstallthefixturesafely《Readcarefullyandfollowalltheinstructionsintheguide》
Pleasefollowthefixturesʼindicationorspecificationforthedistanceofirradiatedarea.
(Causesofchangeinshape,changeincolorofirradiatedobjects)
Pleasecontactifyouarenotabletojudgewhetherinstallation
environmentissuitabletotheplacesornot.
Onlyqualifiedpersonmayworkonelectricwiringandequipment.(Causeofaccidents)
Besurepowersupplyvoltageiswithin±6%mentionedinratingplateortheguide.(Causesofshortlifeoflamps・electrification・fire)
Besureallthewiresandcodesarenotdamaged.(Causesoffalling・damage)
Pleasefollowthefixturesʼinstructionorthisguidetoinstallthefixtureandlamp.(Causesoffalling・electrification・fire)
Switchoffthepowerwheninstallingthelamp.(Causesofelectrification)
Donottouchthefixturewhenswitchisonorjustturnofftheswitchbecauseofhightemperature.
Donotputorcoverthefixturebyanycloths,papers,orinsulators.(Causesofnotlighting・fire)
Donotplaceanymetallicorflammableobjects.(Causeofelectrification・fire・brokenfixture)
Makesuretoinstallallthepartsoffixturesbesidesinstallationandmountingpartswillnottouchwithany
objectsbothinsideandoutsideofceilingsuchaslightingtrack,etc.(Causesoffalling・electrification・fire)
Donotdismountorremodelfixtures.(Causeofelectrification・fire・falling・brokenfixtures)
Donotoperatewithwethands.
Ifyousmellsmoke,seesmoke,orfindanythingunusual,pleaseturntheswitchoffandaskconstruction
companiestorepair.(Causeofelectrification・fire)
Makesuretheconstructionwillnotaffectanyfirepreventionsystemssuchassprinklerbyheatfromthefixture.
(Causesforimproperoperation)
Usealternatingcurrent.Pleasefollowratingplateoffixturesforpowersupplyfrequency.
(Causeofelectrification・fire)(50Hz・60Hzcommonuseforballastsandincandescentlampfixtures)
InstallationGuide LightingFixture
Weight
20cm〜 10cm〜
Insulator
InsulatorInsulator
10cm〜
0.325kg
0.325kg
MPP-10/0300/F/R
MPP-10/0300/F/J
MPP-10/0300/F/L
(Foundationframeequipment)
MPP-10/0300/F/R MPP-10/0300/F/J MPP-10/0300/F/L
PRISM
MPP-10/0600/F/R MPP-10/0600/F/J MPP-10/0600/F/L
MPP-10/1200/F/R MPP-10/1200/F/J MPP-10/1200/F/L
0.650kg
0.650kg
0.650kg
MPP-10/0600/F/R
MPP-10/0600/F/J
MPP-10/0600/F/L
1.300kg
1.300kg
1.300kg
MPP-10/1200/F/R
MPP-10/1200/F/J
MPP-10/1200/F/L
Foundationdownlight
Installation Guide LightingFixture
ToinstallModuleXsafety
1-20-6BF1Ebisuminami,Shibuya-ku,
Tokyo,150-0022,Japan
Tel:81-3-5768-3681
4-1-21Kitahama,Chuo-ku,Osaka、
541-0041,Japan
Tel:81-6-7167-2474
1-8-30-1Daimyou,Chuou-ku
Fukuoka,810-0041,Japan
Tel:81-92-732-4211
TOKYO OSAKA FUKUOKA
R
Caution
Installation Diagram
Bendinwardsothatthesafetywire
mountingbracketdoesnotinterferewith
theinstrument.
Theconnectorisplacedbetween
themountingframeandtheinstrument,
andtheinstrumentisinstalledon
themountingframe.
c
1
1
1
1
44
4
3
3
2
2
2
2
Besuretoturnoffthepowerbefore
startingwork.
d
Inputconnector
Outputconnector
Equipmentinstallation
(implantation,directattachment)
Openthesafetywiremountingbracket
downwardandattachthesafetywire.
Connecttheconnectoronthedriverside
andtheconnectorontheinstrumentside.
Checkthattheconnectorislockedand
cannotberemovedafterconnection.  Safetywiremounting
bracket
Bendthesafetywiremountingbracketdownward
Safetywire
【Buried】
【Directattachment】
Mountingspring
Mountingframe(soldseparately)
ExclusiveDriver(soldseparately)
Connectioncable
Mountingplate(soldseparately)
1
1
Connecttheconnectingcablewith
connectortotheoutputofthedriver.
Whencrimping,besuretocutoffthesolderand
crimpit.(Causeofpoorcrimpcontact)
Connecttheconnectingcableanddriver
accordingtotheattachedlabel.
a
PowerconnectionDCcable(soldseparately)
ExclusiveDriver(soldseparately)
Crimpingby3
Driver
Connectioncable
Powersupplyinstallation
Cutoffsolder
Pleasecrimpinaplacewithoutsolder
a
Electricalwire
2
2
Installthedriverintheceiling.
(Makesuredrivermaintenanceispossible
inaccordancewiththetechnical
standardsforwarequipment)
Powerline
PWMsignalline ToPWMdimmer
Driver
c
Safetywire
Bendthesafetywiremountingbracketupward
d
Installation Details
Installtheinstrumentsothatitissecurely
fixedtotheframemountingsprings
(2places).
Makesurethattheinstrumentdoesnot
protrudefromtheframe.
Ceiling
surface
+Red/Redandwhite
−Black/Black&White −Black
+Red
Polaritylabelforfoundation
1000/3000
Equipmentthatcanbeattachedtothemountingframe
anddirectmountingplate
300types
Note:300instrumentscannotbeinstalledon1200mountingframes
0300Singletype
0300Concatenationtype
Mounting
frame
Installableinstruments
Mountingplate
Decidethenumberofunits
tobeconnected
ContentsPrecautions
Maximumoutputpowerofthedriver
(soldseparately)
Modelnumber
60
180
Outputpower(W)
NTC-E060CV0241
NTC-E180CV0241
Full length 300 600 900 1200 1500
1500
1800
1800
2100
2100
2400
2400
7.4 14.8 22.2 29.6 37.0 44.4 51.8 59.2
Wall washer
Foundation 14.8 29.6 44.4 59.2
NTS-E060CV0241
Power consumption
2700 3000 3300 3600
66.6 74.0 81.4 88.8
74.0 88.8 103.6 118.4 133.2 148.0 162.8 177.6
NTS-E180CV0241
(W)
(W)
Totallengthofequipmentthatcanbeusedbydriver(excludingpowerconsumptionofthedriver)
Connectaccordingtothepolaritylabel
attachedtotheconnectioncable.
Connectioncable
Safetywiremounting
bracket
Safetywire
【Buried】 【Directattachment】
Ceilingsurface
Wall washer
Foundation
Power consumption
Mounting
frame
Mountingplate
600types
Installableinstruments
0600Singletype
1200types
Installableinstruments
P06Concatenationtype0600Concatenationtype
Mountingframe
Mountingplate
1200Singletype
ExclusiveDriver(soldseparately)
MPP-10/0300/F/R MPP-10/0300/F/J MPP-10/0300/F/L
MPP-10/0600/F/R MPP-10/0600/F/J MPP-10/0600/F/L
MPP-10/1200/F/R MPP-10/1200/F/J MPP-10/1200/F/L
Driver
Firstconnectedunit
Secondconsolidatedunit
3rdconsolidated
Decidethenumberofdevicestobeconnected
andthenumberofdriversaccordingtothe
capacityofthedriver.
Whenconnecting,instrumentscanbeconnectedwithconnectors,
butthetotallengthofconnectionsshouldbewithin2.4m.
Exceeding2.4mmaycauseequipmentfailure.Whenconnectingmorethan
2.4m,donotconnectwiththeconnector,andconnecttothepowerdriver
in2circuits.
※Note
1200
1200 1200
Driver
180W
1200
1200 1200
180W
WhenthreeL1200sareconnected
Driver
Lightingfixture
Lightingfixture
PowerconnectionDCcable(soldseparately)
Full length
0300Concatenationtype
MPP-OP/DC02/1000・3000
PRISM Foundationdownlight
Connectoristilted
Gap
Arrangethewiressothattheconnector
doesnottilt.
Installwithoutgapsbetweenlighting
fixtures.
Avoidmountingspringontheconnector.

This manual suits for next models

8

Other Modulex Light Fixture manuals

Modulex SL-B9351D User manual

Modulex

Modulex SL-B9351D User manual

Modulex MMP-080S/5H/1E/10B/Z2/2 User manual

Modulex

Modulex MMP-080S/5H/1E/10B/Z2/2 User manual

Modulex MMP-080W/FLF User manual

Modulex

Modulex MMP-080W/FLF User manual

Modulex MMP-080W/20B/Z1/2 User manual

Modulex

Modulex MMP-080W/20B/Z1/2 User manual

Modulex SX-B9451D/CE User manual

Modulex

Modulex SX-B9451D/CE User manual

Modulex MMP-080A/10B/Z1/2 User manual

Modulex

Modulex MMP-080A/10B/Z1/2 User manual

Modulex MSP-080F User manual

Modulex

Modulex MSP-080F User manual

Modulex LINEAR150 User manual

Modulex

Modulex LINEAR150 User manual

Modulex MSP-080A/10B/DL/3 User manual

Modulex

Modulex MSP-080A/10B/DL/3 User manual

Modulex UB9451D/1.2/RB User manual

Modulex

Modulex UB9451D/1.2/RB User manual

Modulex MMP-100A/FLF/DL/3 User manual

Modulex

Modulex MMP-100A/FLF/DL/3 User manual

Modulex MMP-060S Series User manual

Modulex

Modulex MMP-060S Series User manual

Modulex JIAKARI MMP-100F/30B/DL/3 User manual

Modulex

Modulex JIAKARI MMP-100F/30B/DL/3 User manual

Modulex MMP-100D/SH User manual

Modulex

Modulex MMP-100D/SH User manual

Modulex MMP-130S/5H User manual

Modulex

Modulex MMP-130S/5H User manual

Modulex LINEAR100 User manual

Modulex

Modulex LINEAR100 User manual

Modulex MMP-080S/5H User manual

Modulex

Modulex MMP-080S/5H User manual

Modulex MMT-131/TLF/01 User manual

Modulex

Modulex MMT-131/TLF/01 User manual

Modulex MMP-060S Series User manual

Modulex

Modulex MMP-060S Series User manual

Modulex SLICK JIAKARI MSP-100F/DL/3 User manual

Modulex

Modulex SLICK JIAKARI MSP-100F/DL/3 User manual

Modulex MMP-080A/10B User manual

Modulex

Modulex MMP-080A/10B User manual

Modulex MMP-130S User manual

Modulex

Modulex MMP-130S User manual

Modulex MMP-100S/1H/1E/30B/Z2/2 User manual

Modulex

Modulex MMP-100S/1H/1E/30B/Z2/2 User manual

Modulex MPP-10/0300/COS/S User manual

Modulex

Modulex MPP-10/0300/COS/S User manual

Popular Light Fixture manuals by other brands

Lightolier Lytespan 8103 specification

Lightolier

Lightolier Lytespan 8103 specification

Honeywell ExiLED Series manual

Honeywell

Honeywell ExiLED Series manual

Larson Electronics GL-3 Series instruction manual

Larson Electronics

Larson Electronics GL-3 Series instruction manual

RSA Lighting QCT-1675BK Specification sheet

RSA Lighting

RSA Lighting QCT-1675BK Specification sheet

CAME LP24 quick start guide

CAME

CAME LP24 quick start guide

Super Vision International SaVi-PL-12-50 Installation instructions & owner's manual

Super Vision International

Super Vision International SaVi-PL-12-50 Installation instructions & owner's manual

GE FCB-XM-3D-MK0292-120V instruction manual

GE

GE FCB-XM-3D-MK0292-120V instruction manual

OCL X Series manual

OCL

OCL X Series manual

Elation PROTEUS HYBRID user manual

Elation

Elation PROTEUS HYBRID user manual

Ibiza LMH410Z user manual

Ibiza

Ibiza LMH410Z user manual

Chauvet Lrgrnd 300E Beam user manual

Chauvet

Chauvet Lrgrnd 300E Beam user manual

Larson Electronics EPL-WPLED-100W-RT-DIMM instruction manual

Larson Electronics

Larson Electronics EPL-WPLED-100W-RT-DIMM instruction manual

Lightolier G7075 instruction sheet

Lightolier

Lightolier G7075 instruction sheet

Larson Electronics SPLT-1.59K-800A-30-4X100W-LED-MS Installation

Larson Electronics

Larson Electronics SPLT-1.59K-800A-30-4X100W-LED-MS Installation

Integral LED ILSTRGBA159B Installation instruction

Integral LED

Integral LED ILSTRGBA159B Installation instruction

Cooper Lighting CHG specification

Cooper Lighting

Cooper Lighting CHG specification

U-Line H-7272 manual

U-Line

U-Line H-7272 manual

RSA Lighting Galleria Series CGCV Specification sheet

RSA Lighting

RSA Lighting Galleria Series CGCV Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.