Tool Kit for CTX280 Receptacle Terminals: >1.0 - 2.0mm² metric, Type I O wire
Doc No: AT -6381982HM Release Date: 12-09-09 UNCONTROLLED COPY Page 5 of 9
Revision: B Revision Date: 09-24-10
For the Battery Power Tool:
1. Cycle the Battery Power Tool to crimp the terminal to the wire.
2. Remove the crimped terminal from the terminal locator by pressing down on the wire stop and gently pulling on
the wire. The terminal locator can be in either position.
3. Visually inspect the crimped terminal for proper crimp location.
Maintenance
It is recommended that each operator of the tool be
made aware of, and responsible for, the following
maintenance steps:
1. Remove dust, moisture and other contaminants
with a clean brush, or soft, lint-free cloth.
2. Do not use any abrasive materials that could
damage the tool.
3. Make certain all pins; pivot points and bearing
surfaces in the tool head are protected with a
thin coat of high quality machine oil. Do not oil
excessively. This tool was engineered for
durability, but like any fine piece of equipment, it
needs cleaning and lubrication for a maximum
service life of trouble-free crimping. The use of light oil, such as 30 weight automotive oil, every 5,000 crimps
or monthly, will significantly enhance the tool life and ensure a stable calibration. ee Figure 8A or 8B for
lubrication points.
4. tore the tool in a clean and dry area when
not in use.
Miscrimps or Jams for Crimp Hand
Tools Only (See Fi ure 11)
hould this tool ever become stuck or jammed in
a partially closed position, Do Not force the
handles open or closed. The tool will open
easily by rotating the small slotted screw marked
with an arrow. ee Figure 11.
Warranty
This tool kit is for electrical terminal crimping
purposes only. This tool kit is made of the best
quality materials. All vital components are long life tested. All tools are warranted to be free of manufacturing
defects for a period of 30 days. hould such a defect occur, we will repair or exchange the tool kit free of charge.
This repair or exchange will not be applicable to altered, misused, or damaged tools.
CAUTION: Molex crimp specifications are valid only when used with Molex terminals and tooling.
Fi ure 7
WIRE
INSULATION
PUNCH
CONDUCTOR ANVIL
INSULATION
ANVIL
WIRES AGAINST
LOCATOR STOP
CONDUCTOR
PUNCH
TERMINAL
LUBRICATION
POINTS
(BOTH SIDES)
LIGHT OIL
(EVERY MONTH
OR
5,000 CRIMPS)
Fi ure8A
Fi ure 8B