arning: The exhaust of the safety valve must be connected to a drain
so it can flush out incoming hot water.
Connecting to a system with zone valves
Always leave a zone o en. It is advised to have an anti-condensation
valve installed.
Hot water production kit (optional)
On some hydro stove models it is ossible to install a kit
on board the a liance for the roduction of hot water.
This o tional feature rovides unmatched comfort
because everything is com letely automatic and
controlled by the control unit.
Note: The kit must be connected to the hydraulic system in accordance
with its in ut and out ut indications, the maximum admissible ressure is
2 bars (this o eration must be carried out by a qualified technician).
Operating Conditions
The hydro stove was designed to be used in normal environments,
where there is no danger of ossible fire outbreaks or ex losions. The
dis osal of combustion waste must be carried out in accordance with
local regulations. While using the hydro stove, the settings cannot be
changed or the rotective casings removed. The control unit must be
adjusted by qualified ersonnel.
The maintenance of the roduct must be carried out by s ecialized
com anies in the maintenance of heating a liances and authorized by
Moretti Design, who will submit it to all the check u s required by current
regulations.
Use 6 mm diameter and 30 mm average length wooden pellets for
the hydro stove.
Caution: A hydro stove that has been modified or altered, must be
subjected to further verifications in compliance with the law. The
improper connection of the hydro stove heater to the flue and the
non-compliance with standard regulations for the installation of air
vents, can cause serious danger to people.
Long-term non-use conditions
If the hydro stove has not been used for a long eriod of time, it is
recommended to contact a qualified technician to carry out the following
o erations:
- Place the switch in the 0 osition
- Close all the valves of the heating and domestic water system
- Em ty the system to avoid the water from freezing
Residual Risks
Certain arts of the stove, in articular the glass and flue, while in use
overheat and can cause burns, do not touch or handle unless with the
utmost care.
The electrical arts can cause serious damage, do not touch these arts
without having disconnected the cable from the main ower su ly.
SAFETY DEVICES
Breakage of the exhaust fan: If for any reason the fan breaks, a safety
measure intervenes and blocks the ellet flow (Er02), an alarm goes off
and sto s the stove’s function.
Breakage of the auger motor: If the auger motor sto s feeding ellet,
the system still continues to function on minimum levels then an alarm
goes off and the stove blocks (Er12, Er03).
Failed ignition: The system foresees 1 ignition attem t, if it is not
successful the hydro stove goes into safe mode then in blocks (Er12).
Check that the burner is clean and well ositioned before attem ting
another ignition.
If the burner is not cleaned, the next ignition may cause a little
deflagration inside the combustion chamber. If this occurs, the
manufacturer will not accept any responsibility for damage to
persons, animals or things.
On models with the automatic burner cleaning function (PLUS CLEAN),
the burner before each ignition automatically cleans itself, thus avoiding
the user having to o en the front door and manually cleaning it.
Electrical protection: The system is rotected with a 4 A fuse that is
located on the back of the hydro stove. To re lace it, extract the tray next
to the switch only after disconnecting the ower cable from the ower
su ly, re lace the broken fuse and reinsert the tray, if the new fuse
immediately breaks, contact a technician.
Exhaust fume safety: If there are any anomalies with the smoke
ex ulsion from the system, an alarm will go off and the system will block
(Er02).
Pellet safety: If the tem erature inside the ellet tank exceeds the
safety level, the system blocks (Er01). The reinstatement is automatic,
contact a qualified technician.
ater temperature safety: In case the water tem erature in the boiler
exceeds the safety level, the system goes into block (Er01). The
reinstatement is manual and must be carried out by a qualified
technician by ressing the reset button behind the hydro stove.
Breakage of the pump: If the um sto s, the system goes into alarm
and sto s (Er01, Er04).
ater pressure safety: The ressure of the system is controlled by an
electronic ressure transducer and must be in between 0,5 bar (50 kPa)
and 1,5 bar (150 kPa), if these conditions are not com lied with the
system goes into block. If the system goes over 3 bar, an automatic
safety valve o ens and releases the excessive ressure. To regulate the
ressure within the function range, adjust the discharge valve behind the
stove or on the radiator.
Power failure: If there is a short ower failure in the ower su ly, the
system will go into block (Er15), if the lack of electricity is not brief, the
stove could release a small quantity of smoke in the room, if the air
intake has not been correctly connected to the outside. This is caused
by the scarce draw of the chimney flue and does not represent any
risk for one’s safety. When the ower comes back, the system
switches itself off.
arning: In the case the chimney catches fire, call the fire brigade.
MINIMUM SAFETY DISTANCES
Kee fuels and flammable substances at an adequate distance from the
stove. For minimum distances from flammable materials, one can refer
to the roducts identification late located on the back of the stove.
Caution: For some models the minimum safety distance from
flammable materials may be different than those shown in the
figure below. Therefore, always refer to the product identification
plate generally located on the back of the stove to ensure minimum
safety distances specific model.
Note: If one wants to install the hydro stove near a non-flammable wall,
it is ossible to lace it directly in contact with the wall, as long as it does
not obstruct any access to the electrical com onents or connections or
maintenance interventions.
Distance in mm