Morrell SW-UNM-9FE User manual

SW-UNM-9FE
8-Port 10/100Mbps + 1-Port 100Mbps Uplink
Unmanaged Ethernet Switch
User Manual
Ver. 1.0

1
Table of Contents
Chapter 1 Product Introduction
............................................................................................. 3
1.1 Product Overview ............................................................................................................. 3
1.2 Features ............................................................................................................................ 3
1.3 Environments .................................................................................................................... 3
Chapter 2 Installation
............................................................................................................... 4
2.1 Installation method ........................................................................................................... 4
2.2 Turn on the switch ............................................................................................................ 4
2.3 Indicator LED .................................................................................................................... 5
2.4 Network Connection ........................................................................................................ 5
Chapter 3 Trouble Shooting
................................................................................................... 7
3.1 Indicators ........................................................................................................................... 7
3.2 Power ................................................................................................................................. 7
3.3 Cable .................................................................................................................................. 7
Appendix: Technical Specifications
.................................................................................... 8

2

3
Congratulations
on
your
purchasing
of
the
switch
.
This switch provides a simple,
economical, standard and high performance solution for you.
Please read the entire user
manual before using the product and save it for future reference.
Chapter 1 Product Introduction
1.1 Product Overview
The product is 8-port 10/100Mbps unmanaged Ethernet Switch provides the seamless
network connection. It is easy to install, plug and play, no management. with desktop
design, all-metal chassis and elegant appearance, outstanding performance and quality.
Dynamic LED indicator to monitor switch status and troubleshooting work. It provides 8-
10/100Mbps Auto-Negotiation RJ45 ports and 1 uplink port, the port 1 and UP-LINK called
Shared port, they can't used at the same time. All ports support auto-negotiation function,
store and forward technology, dynamic memory assignment. It will boost your network
performance up to full duplex data transfer.
1.2 Features
Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3x standards
8 10/100Mbps Auto-Negotiation RJ45 ports supporting Auto-MDI/MDIX, 1 Uplink Port
Supports IEEE 802.3x flow control for Full Duplex mode and backpressure for half-
duplex mode
Store and forward mode operates
Supports MAC address auto-learning and auto-aging
LED indicators for monitoring power, link, activity
Metal case, desktop or wall-mounting design
External Power Adapter supply
1.3 Environments
Operating Temperature: 0℃~40℃
Storage Temperature: -10℃~70℃
Operating Humidity: 10%~90% non-condensing
Storage humidity: 5%~90% non-condensing

4
Chapter 2 Installation
Before installing the switch, make sure that the following the "packing list" listed OK. If any
part is lost or damaged, please contact your local agent immediately. In addition, make
sure that you have the tools install switches and cables by your hands.
Switch x 1
User's Manual x 1
External Power Adapter(DC 5V/550mA) x 1
The site where you place the switch may greatly affects its performance. When installing,
take the following into your consideration.
2.1 Installation method
Follow the below guide to install the switch.
Please install the switch in a fairy cool and dry place. See the Technical Specification
for the acceptable temperature and humidity operation ranges.
Installing the switch on a sturdy, level surface that can support its weight.
Connect the power cord to the switch and the power outlet. The distance is less than
150cm.
Leave at least 10cm (about 4 inches) of space at the front and rear of the switch for
ventilation.
2.2 Turn on the switch
Please plug the external power adapter into the switch, when the switch is power on, the
power indicator will be light on the front panel of the switch shines.
Note:
Please confirm the voltage is correct before power on, otherwise the switch will be
damaged.
There is a power supply socket on the side of the switch. The power input is:
DC 5V/550mA.

5
8-port 10/100M Switch back panel
The uplink port is used for cascading between two switches. It shared the same channel
with adjacent port. Consequently, if you use the uplink port, another adjacent normal port
cannot be used for communicating with other devices.
2.3 Indicator LED
LED Color Status Description
Power Green
On
Power
is
supplied
Off
No
power is supplied
Link/Act
(1-8)
Green
On
A valid link
is
established
Flashing
Data
packets
transmitted or received
Off
No
link
is
established
2.4 Network Connection
Connect your devices (computer, router, switch, etc.) to the ports with a CAT-5/CAT-
5e/CAT-6 network cable. Since the switch supports Auto MDI/MDI-X you can use either a

6
straight or crossed network cable.

7
Chapter 3 Trouble Shooting
The Switch can be easily monitored through panel indicators to assist you identify some
problems. This section describes common problems you may encounter and where you
can find possible solutions.
3.1 Indicators
If Link indicator does not light up after making a connection, you may check whether
network interface (e.g., a network adapter card on the attached device), network cable, or
switch port is defective or not. Be sure the cable is plugged into both the Switch and
corresponding device. Verified the proper cable type is used and its length does not exceed
specified limits.
3.2 Power
If the power indicator does not turn on, when the external power adapter is plugged in the
power socket, you may have a problem with power adapter or power socket. However, if
the switch powers off after running for a while, check for loose power connection, power
loses or surges at power socket. If you still cannot resolve the problem, contact your local
dealer for assistance.
3.3 Cable
RJ-45 Ports: Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-
45 connections:
1. CAT-3/CAT-4/CAT-5 UTP cable when the switch connect with a 10-Base T device.
2. CAT-5/CAT-5e/CAT-6 UTP cable when the switch connect with a 100-Base TX device.
3. Be sure that the length of any twisted-pair connection does not exceed 100 meters
(328 feet).

8
Appendix: Technical Specifications
Standards IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX,
Network Media (Cable)
10BASE-T: UTP category 3,4,5 cable (maximum 100m)
100BASE-T: UTP category 5 cable (maximum 100m)
Number of Ports
8-10/100M Auto-Negotiation RJ45 port(Auto
MDI/MDIX),
1 Uplink Port
Transfer Method Store-and-Forward
Switching Capacity 1.6Gbps
MAC Address Learning Automatically learning, automatically Update 2K Table
Frame Filtering and
Forward Rate 10Mbps: 14880pps, 100Mbps: 148810pps
Dimensions (L × W × H) 140*77*28mm
Environment
Operating Temperature: 0℃ - 40℃
Storage Temperature: -10℃ - 70℃
Operating Humidity: 10%~90% non-condensing
Storage humidity: 5%~90% non-condensing
Table of contents
Other Morrell Switch manuals
Popular Switch manuals by other brands

LEGRAND
LEGRAND Celiane 670 85 manual

schmersal
schmersal AZ 17-11ZK operating instructions

Endress+Hauser
Endress+Hauser Liquiphant M FTL50 Safety instructions

Endress+Hauser
Endress+Hauser Liquiphant FTL51B operating instructions

Danfoss
Danfoss TS715 Si Installation & user's instructions

Vantec