manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Motorline
  6. •
  7. Control Unit
  8. •
  9. Motorline MC10-11 Use and care manual

Motorline MC10-11 Use and care manual

V2.0
REV. 05/2019
MC11MC11 EN
USER’S AND INSTALLER’S MANUAL
A B
1B
4A
4A
5A
9B
8A
5A
5B
11A
11A
12
13
ENEN
COMPONENT'S CONNECTION TO THE CONTROL BOARD
TECHNICAL SPECIFICATIONS
MAIN MENU
ESSENTIAL INSTALLATION STEPS
INSTRUCTIONS FOR FINAL CONSUMERS/TECHNICIANS
CONNECTOR’S DESCRIPTION
PROGRAMMING PRE-RECOMENDATIONS
EXTENDED MENU 
. SAFETY INSTRUCTIONS
. CONNECTION SCHEME
. THE CONTROL BOARD
. CONFIGURATION
. TROUBLESHOOTING
. CONTENT
INDEX
EXTENDED MENU 
EXTENDED MENU 
RESET OF CONTROL BOARD
01. SAFETY INSTRUCTIONS
This product is certified in accordance with European
Community (EC) safety standards.
This product complies with Directive 2011/65/EU of the
European Parliament and of the Council, of 8 June 2011, on
the restriction of the use of certain hazardous substances in
electrical and electronic equipment.
(Applicable in countries with recycling systems).
This marking on the product or literature indicates that the
product and electronic accessories (eg. Charger, USB cable,
electronic material, controls, etc.) should not be disposed
of as other household waste at the end of its useful life. To
avoid possible harm to the environment or human health
resulting from the uncontrolled disposal of waste, separate
these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material
resources. Home users should contact the dealer where they
purchased this product or the National Environment Agency
for details on where and how they can take these items
for environmentally safe recycling. Business users should
contact their vendor and check the terms and conditions
of the purchase agreement. This product and its electronic
accessories should not be mixed with other commercial
waste.
This marking indicates that the product and electronic
accessories (eg. charger, USB cable, electronic material,
controls, etc.) are susceptible to electric shock by direct or
indirect contact with electricity. Be cautious when handling
theproductandobserveallsafetyproceduresinthismanual.
ATTENTION:
EN
GENERAL WARNINGS
•This manual contains very important safety and usage information.
very important. Read all instructions carefully before beginning the
installation/usage procedures and keep this manual in a safe place
that it can be consulted whenever necessary.
•This product is intended for use only as described in this manual. Any
other enforcement or operation that is not mentioned is expressly
prohibited, as it may damage the product and put people at risk
causing serious injuries.
•Thismanual is intendedfirstlyforspecializedtechnicians, and does not
invalidate the user’s responsibility to read the “User Norms” section in
order to ensure the correct functioning of the product.
•The installation and repair of this product may be done by qualified
and specialized technicians, to assure every procedure are carried
out in accordance with applicable rules and norms. Nonprofessional
and inexperienced users are expressly prohibited of taking any action,
unless explicitly requested by specialized technicians to do so.
•Installations must be frequently inspected for unbalance and the
wear signals of the cables, springs, hinges, wheels, supports and other
mechanical assembly parts.
•Do not use the product if it is necessary repair or adjustment is
required.
•When performing maintenance, cleaning and replacement of parts,
the product must be disconnected from power supply. Also including
any operation that requires opening the product cover.
•The use, cleaning and maintenance of this product may be carried
out by any persons aged eight years old and over and persons whose
physical,sensorialormentalcapacitiesarelower,orbypersonswithout
any knowledge of the product, provided that these are supervision
and instructions given by persons with experienced in terms of usage
of the product in a safe manner and who understands the risks and
dangers involved.
•Children shouldn’t play with the product or opening devices to avoid
the motorized door or gate from being triggered involuntarily.
WARNINGS FOR TECHNICIANS
•Before beginning the installation procedures, make sure that you have
all the devices and materials necessary to complete the installation
of the product.
•You should note your Protection Index (IP) and operating temperature
to ensure that is suitable for the installation site.
•Provide the manual of the product to the user and let them know how
to handle it in an emergency.
•If the automatism is installed on a gate with a pedestrian door, a door
locking mechanism must be installed while the gate is in motion.
•Do not install the product “upside down” or supported by elements do
not support its weight. If necessary, add brackets at strategic points
to ensure the safety of the automatism.
•Do not install the product in explosive site.
•Safety devices must protect the possible crushing, cutting, transport
and danger areas of the motorized door or gate.
•Verify that the elements to be automated (gates, door, windows,
blinds, etc.) are in perfect function, aligned and level. Also verify if the
necessary mechanical stops are in the appropriate places.
•The centralmust beinstalledon a safeplace of any fluid (rain, moisture,
etc.), dust and pests.
•You must route the various electrical cables through protective tubes,
to protect them against mechanical exertions, essentially on the
power supply cable. Please note that all the cables must enter the
central from the bottom.
•If the automatism is to be installed at a height of more than 2,5m from
the ground or other level of access, the minimum safety and health
requirements for the use of work equipment workers at the work of
Directive 2009/104/CE of European Parliament and of the Council of 16
01. SAFETY INSTRUCTIONS
EN
September 2009.
•Attach the permanent label for the manual release as close as possible
to the release mechanism.
•Disconnect means, such as a switch or circuit breaker on the electrical
panel, must be provided on the product’s fixed power supply leads in
accordance with the installation rules.
•If the product to be installed requires power supply of 230Vac or
110Vac, ensure that connection is to an electrical panel with ground
connection.
•The product is only powered by low voltage satefy with central (only
at 24V motors)
WARNINGS FOR USERS
•Keep this manual in a safe place to be consulted whenever necessary.
•If the product has contact with fluids without being prepared, it must
immediately disconnect from the power supply to avoid short circuits,
and consult a specialized technician.
•Ensure that technician has provided you the product manual and
informed you how to handle the product in an emergency.
•Ifthesystemrequiresanyrepairormodification,unlocktheautomatism,
turn off the power and do not use it until all safety conditions have
been met.
•In the event of tripping of circuits breakers of fuse failure, locate
the malfunction and solve it before resetting the circuit breaker or
replacing the fuse. If the malfunction is not repairable by consult this
manual, contact a technician.
•Keep the operation area of the motorized gate free while the gate in in
motion, and do not create strength to the gate movement.
•Do not perform any operation on mechanical elements or hinges if the
product is in motion.
RESPONSABILITY
•Supplier disclaims any liability if:
•Product failure or deformation result from improper installation
use or maintenance!
•Safety norms are not followed in the installation, use and
maintenance of the product.
•Instructions in this manual are not followed.
•Damaged is caused by unauthorized modifications
•In these cases, the warranty is voided.
01. SAFETY INSTRUCTIONS
SYMBOLS LEGEND:
• Important safety
notices
• Useful information
• Programming
information
• Potentiometer
information
• Connectors
information
• Buttons
information
A B
ENEN
. THE CONTROL BOARD
TECHNICAL CHARACTERISTICS CONNECTOR’S DESCRIPTION
. THE CONTROL BOARD
The MC11 is a 24Vdc or 12Vdc electronic central unit for the automation of swing gates, sliding gates and
bollards with radio receiver and built-in battery charger.
• Transformer supply 110V/230Vac 50/60Hz 120W máx.
• Control board supply 20Vac 50/60Hz 120W máx.
• Intermittent output 24Vdc 4W máx.
• Emergency battery input 24Vdc 7A/h máx.
• Engines Output 24Vdc 2 x 50W máx.
• Electric Lock Output 24Vdc 12W máx
• Photocells suplly 24Vdc 3W máx.
• Indication lamp output 12Vdc 3W máx.
• Working Temperature -25C to +55C
• Radio receiver Rolling Code, 433,92 Mhz
• Max TX Code in memory 120 (CODE or CODE PED)
• Control board box dimensions 240 x 190 x 110mm
• Protection grade IP56
CONNECTOR’S DESCRIPTION
CLOSED
GATE GATE IS OPENING OPENED GATE GATE IS
CLOSING
11 + 14 EXTERNAL PHOTOCELLS
(with closing intervention) Without
influence Without influence Do not let it close. Stop and
reverse
12 + 14
13 + 14 INTERIOR PHOTOCELLS
(with opening intervention) Do not let
it open
Stops and stands still
waiting for the photoce-
lls to be restored Without influence Without
influence
15 + 14 ANTICRUSHING
PHOTOCELLS
(with opening intervention)
Do not let
it open
Stops and relieves
slightly. If the photocells
are restored, the gate
is stopped waiting for a
new order to continue
opening.
Do not let it close. If
the photocells have
been restored, the
gate is stopped wai-
ting for a new order
to close.
Without
influence
16 + 14
Entrada para pólo quente da Antena
Entrada para massa da Antena
NC input for anti-crushing photo-cells
NC input for anti-crushing photocells
Common line
NC input for interior photocells
NC input for external photocells
NC input for external photocells
NO input for emergency stop devices
Common line
NO input for Pedal Openning button
NO input for Pedal Openning button
Output 0V to Flashlight
Output 12Vdc 3W to Flashlight
Output 0V for Accessories power supply
Output 24Vdc 3W for Accessories power sup-ply
Output 0V for Electric Lock
Output 12V 24Vdc for Electric Lock
Output 0V to Motor 2
Output 24Vdc max 50W to Motor 2
Output 0V to Motor 1
Output 24Vdc max 50W to Motor 1
Output 0V to Flashlight
Output 24Vdc 4W to Flashlight
Input 24Vdc 30W max to Solar Panel
Input 0V to Solar Panel or Emergency Battery
Input 24Vdc 1,2/7Ah ou 12Vdc 1,2Ah (only motor TELICA) max to Emergency Battery
Power Input 20Vdc 120W max
Power Input 20Vdc 120W max
CN2
CN1
03+04 • Emergency battery: In case of power failure, these batteries will supply power to the automation
operation. The number of maneuvers depends on the installed battery and its condition.
05 • Solar panel: Device input to charge the emergency battery.
06+07 • Flashing light:Output for flashlight or courtesy. Its operation can be set in the CODE function of
Extension Menu 2 (page 9B).
01+02 • Electric lock: 24Vdc output with a maximum capacity of 12W.
03+04 • Power supply Accessories: Power supply Accessories: Output 24Vdc with maximum capacity of 3W.
05+06 • Signal lamp: Output 12Vdc with maximum capacity of 3W. The light blinks slowly when the gate is
opening and blinks rapidly when the gate is closing.
07+09 | 08+09 • Pushbutton: NO input for gate activation buttons. The type of operation is defined in the CODE
function of the Extension Menu 1.
09+10 • STOP: NC input for emergency stop devices.
11+14 | 12+14 | 13+14 | 15+14 | 16+14 •
Photocell Circuit:
A B
ENEN
Variable consumption Linear consumption
. THE CONTROL BOARD
. PROGRAMMING
PROGRAMMING PRERECOMENDATIONS
ESSENTIAL INSTALLATION STEPS
01 • Connect all accessories according to the wiring diagram (page 12).
02 • Connect the control board to a 20Vac power supply.
03 • In the EXTENSION MENU 1, check that the slowdown is on / off and set it as you wish.
04 • Program the automatic course - MAIN MENU (page 5B).
05 • Program a command (page 6A).
• POWER AND SPEED OF MOTORS  VR
• SENSITIVITY  VR
FORZA VELOCITA: The control board has a trimmer VR1 to adjust the force and speed of the
motors controlled by the microprocessor. The adjustment can be effected between 50% and
100% the power. At each start-up movement, the control board applies the maximum power
during 2 seconds, even when it is made regulating force to a value than not the maximum.
SENSIBILITA: This potentiometer allows the adjustment of the sensitivity required for the
detection of obstacles, controlled by the microprocessor. The regulation can be
for a time between 0.1 seconds and a maximum of 3 seconds.
When you adjust the trimmer VR1 has to remake course programming, as they could varied
the times of maneuvering and deceleration.
If the motor is moving in the opposite directi-on, turn the power switch off, replace the
motor wires, and then turn it back on.
•PROGRAMMING THE CONTROL BOARD  BUTTONS SEL/SET
SEL button: It makes the selection of the function to change. The selection is identified
by the flashing of the LED corresponding to the selected function at that time.
Pressing the SEL button repeatedly will cycle through the various functions to be
programmed. The selection remains active for 10 seconds, after these time the control
board returns to original status (no active selection).
SET button: Makes programming the selected function through the SEL button.
The SET button may be substituted by a remote control from the latter is programmed.
MAIN MENU
. PROGRAMMING
MAIN MENU
LED LED OFF LED ON
• TIPO MOT. Linear consumption (recommended) Variable consumption
• AUTO PGM Programming Auto = OFF Programming Auto = ON
• CODE No programmed commands Programmed command(s)
• CODE PED. No programmed commands Programmed command(s)
• T. MOT. Working Time = 30sec Programmed Working Time
• T. MOT. PED. Pedestrian Work Time = 10sec Programmed Pedestrian Work Time
• T. PAUSA Automatic Close = OFF Automatic Close = ON
• T. RIT. ANTE Leaf Delay = OFF Programmed time
• TIPO MOT. | LINEAR OR VARIABLE ACTUATION
• AUTO PGM |AUTOMATIC PROGRAMMING NOT RECOMMENDED FOR NONCOURSE ENGINES
The MAIN MENU contains the main functions for automation programming, with direct access via the
SEL key.
The motors with linear actuation do not have variations in the consumption, whereas, the
motors with variable action have different peaks of consumption. You can select 1 of the 2
engine types.
01 • Press SEL button the times necessary until the TIPO MOT. LED starts to flash.
02 •
Press the SET button for 1 second.
03 • The TIPO MOT. LED lights indicating that the motor with variable consumption is selected
and the LED off indicates that the motor with linear consumption is selected.
Program the working time:
01
• Unlock the automatisms, and place the leaves of the gate halfway. Lock again the au-
tomatic controls.
02
•Press SEL button the times necessary until the AUTO PGM LED starts to flash.
03
•Press the SET key continuously, without leaving until the end of the process.
04
•The engine 2 will close until it reaches the stop.
05
• The engine 1 will close until it reaches the stop.
06
• The door will reopen and close (engine 1 and engine 2).
07
• When you reach the end of the course, press SET again to end the opening. AUTO PGM
Factory setting: Linear Consumption
A B
ENEN
. PROGRAMMING
MAIN MENU MAIN MENU
. PROGRAMMING
Instead of using the SET button of the control board, you can use a trasmitter that is already
programmed.
• CODE | PROGRAMMING OF COMMANDS FOR TOTAL OPENING
To program new transmitters:
01 • Press SEL button the times necessary until the CODE LED starts to flash.
02 • Press once the transmitter's button you want to program for 1 second.
03 • The CODE LED lights up permanently, indicating the successful of the programming.
To delete all configured transmitters:
01 • Press the SEL button once, and the CODE LED will begin to flash.
02 • Press the SET key until the CODE LED turn off.
03 • The CODE LED turns off and all transmitters have been deleted.
• CODE PED. |PEDESTRIAN OPERATION
• T. MOT. | PROG. WORKING AND DECELERATION TIME RECOMMENDED FOR ENGINES WITH END OF COURSE
To program new transmitters to pedestrian mode:
01 • Press SEL button the times necessary until the CODE PED LED starts to flash.
02
•Press the transmitter's button that you want to program during 1 second.
03
•The CODE PED LED is lit indicating that the command has been programmed.
To delete all configured transmitters:
01 • Press SEL button the times necessary until the CODE PED LED starts to flash.
02 • Press the SET key until the CODE PED LED turn off.
03 • The CODE LED PED turns off signaling that all the commands have been cleared.
If the CODE LED starts blinking fast, it means that the control board has not accepted
the programming of the command or that it is already stored in memory.
The control board allows to start only one motor in order to permit pedestrian passage.
With this function, pressing the transmitter, will only open the door with the motor 1.
Command programmed Without commands programmed
The control board accepts only Dip-Switch or Rolling Code MOTORLINE transmitters, and
has a maximum capacity of 120. When trying to program the 121º transmitter, all the
programming LEDs will flash simultaneously to indicate that the memory is full.
Command programmed Without commands programmed
This function allows manual programming of working time and deceleration. Use it only if
you can not perform the desired function with the AUTO PGM. The maximum working time is
4 minutes.
NOTE • To carry out this programming, the motors must have a mechanical stop. If you have
made an automatic course program (AUTO PGM function), the control panel will override this
programming and take the programmed course manually.
Factory setting: Working Time = 30sec With working
time No working time
Programming motor's time and slowdown (closed gate):
01 • Press SEL button the times necessary until the T.MOT. LED starts to flash.
02 • Press the SET button for 1 second, so that the Motor 1 start opening.
03 • Press the SET button for 1 second, when the gate is at the desired point to start
deceleration.
04 • Press again SET button when you want to establish the opening limit-switch. At this time,
T. MOT. LED will quickly flash and automatically the motor 2 will start the opening maneuver.
05 • Press the SET button for 1 second, when the gate is at the desired point to start
deceleration.
06 • Press again SET button when you want to establish the opening limit-switch.
07 • The T. MOT.LED will quickly flash indicating that programming for closing can be
performed and automatically the motor 2 starts the closing maneuver. Repeat the process
to program the closing.
Programming motor's time without slowdown (closed gate):
To make the programming without slowdown, leave the gate reach the opening limit switch
and press TWICE (quickly) the SET button. The LED T. MOT. will flash quickly and the motor
starts the closing maneuver. When the gate reaches the closing limit switch again, click SET
twice to finish programming.
If any of the motors do not start the opening, turn the power switch off, replace the
wires of the motor (s), and then turn it back on.
Instead of using the central's SET button during programming, you can use the key of a
remote control that is already programmed.
stops blinking.
NOTE • The control panel automatically sets a 15% slowdown of the total stroke, both at the
end of the opening and at the end.
A B
ENEN
. PROGRAMMING
MAIN MENU MAIN MENU
. PROGRAMMING
• T. MOT. PED | PROGRAMMING PEDESTRIAN WORKING TIME
To activate the pedestrian function, the control board allows to be just activated the operation
of motor 1.
The maximum working time is 4 minutes.
NOTE • To perform this programming is necessary that the motors have limit-switches
or stoppers.
Factory setting: Pedestrian Work Time = 10sec Function ON Function OFF
• T. PAUSA | PROGRAMMING PAUSE TIME FOR AUTOMATIC CLOSING MAX  MIN
Program time:
01 •Press SEL button the times necessary until the T. PAUSA LED starts to flash.
02 •
Press the SET button for 1 second.
03 • Wait the desired time for pause time. (Eg 30 seconds)
04 • Press SET button again.
05 • T. PAUSA LED stays lit and the pause time is set.
This function allows you to set the time that the gate remains open after the end of the opening
maneuver. After this time, the control board automatically initiates the closing.
Factory setting: Automatic Close = OFF With automatic
closing Without automatic
closing
Delete programming:
01 • Press SEL button the times necessary until the T.PAUSA LED starts to flash.
02 • Double-press the SET button within 2 sec.
03 • The T.PAUSA LED turns off and the function stays disabled.
• T. RIT. ANTE | PROGRAMMING THE DOOR DELAY IN CLOSURE  SECONDS MAX.
Set closing delay:
01 • Press the SEL button as often as necessary until the T. RIT. ANTE LED starts flashing.
02 • Press the SET button for 1 second.
03 • Wait for the desired delay time, and press the SET key for 1 second.
Therefore, on closing, the delay time will be stipulated by the option while the opening is fixed
in 2 seconds.
04 • The T. RIT. ANTE LED will light up, signaling the success of the operation.
Delete programming:
01 • Press the SEL button until the T. RIT. ANTE LED will flashing.
02 • Press the SET button twice in less than 2 seconds.
03 • The T. RIT. ANTE LED will off, signaling the success of the operation.
This function can delay up to 15 seconds the start of the closing motor 1 in relation to
the motor 2.
In the aperture, the difference between the start of motor 1 and motor 2 is always 2 seconds,
since T. RIT. ANTE is programmed.
Factory setting: Leaf Delay = OFF Memorized
delay Without delay
Instead of using the central's SET button during programming, you can use the key of a
remote control that is already programmed.
Programming pedestrian working time with deceleration (gates closed):
01 • Press SEL button as often as necessary until the T. MOT. PED. LED starts to flash.
02 • Press the SET button for 1 second, so that the Motor 1 starts to open.
03 •
Press the SET button for 1 second, when the gate is the desired point to start deceleration.
04 • Press again SET button when you want to establish the opening limit-switch. At
this time, T. MOT. PED. LED will quickly flashing and automatically the motor 1 starts
closing maneuver.
05 •
Press the SET button when the gate is at the desired point to start deceleration.
06 • Press again SET button when you want to establish the closing limit-switch.
Programming pedestrian working time without deceleration (gates closed):
To make a program without slowdown, press TWICE the SET button when you want to set the
opening's end.
T. MOT.PED LED will flash quickly and the motor starts the closing maneuver.
When the gate reaches the closing limit switch, click SET twice again to finish programming.
If any of the motors do not start the opening, turn the power switch off, replace the
wires of the motor (s), and then turn it back on.
Instead of using the central's SET button during programming, you can use the key of a
remote control that is already programmed.
A B
ENEN
. PROGRAMMING
• TIPO MOT. |
TRANSMITTER INHIBITION DURING THE OPENING AND PAUSE TIME IF INSERTED
• AUTO PGM |
ELECTRIC BRAKE
Enable / Disable transmitter inhibition:
01 • Enter the Extended Menu 1.
02
• Press SEL button as often as necessary until the TIPO MOT. LED starts to flash.
03
• Press the SET key (1 second) to activate / deactivate the function.
04
•TIPO MOT. LED will turn on/off, signaling the success of the operation.
EXTENDED MENU 
The control panel has an EXTENSIVE MENU 1, with more functions for programming.
To access the options of extended menu 1 follow these instructions:
01 • Press continuously the SET button for 5 seconds and the T.PAUSA LED and T. RIT. ANTE LED will flash al-
ternately.
02 • You have 30 seconds to select functions from the extended menu 1 (using the SEL and SET button), and
that after this time the control board returns to main menu.
EXTENDED MENU 1
LED LED OFF LED ON
• TIPO MOT. Inhibition Commands Opening = OFF Inhibition Commands Opening = ON
• AUTO PGM Electric brake = OFF Electric brake = ON
• CODE Automatic Operation Step by Step Operation
• CODE PED. Opening push = OFF Opening push = ON
• T. MOT. Closing push = OFF Closing push = ON
• T. MOT. PED. Follow Me = OFF Follow Me = ON
• T. PAUSA Alternative intermittence ON/OFF
• T. RIT. ANTE Alternative intermittence ON/OFF
01 • Enter the Extended Menu 1.
02 • Press SEL button the times necessary until the AUTO PGM LED starts to flash.
03 • Press the SET key (1 second) to activate / deactivate the function.
04 • AUTO PGM LED will turn on/off, signaling the success of the operation..
With this function activated, the control panel will reject all command signals during opening
and pause time of the operator. It is important that the function is activated when a magnetic
turn is installed, as the control panel will ignore.
Factory setting: Inhibition Commands Opening = OFF
Inhibition enabled
Inhibit disabled
With this function active, when the automatism finishes a maneuver (reaching the limit
switch), the control board briefly reverses the motor's power supply to stop it immediately
(eg. gates with inclination).
Factory setting: Electric brake = OFF Function ON Function OFF
. PROGRAMMING
EXTENDED MENU 
• CODE |
STEP BY STEP / AUTOMATIC FUNCTIONING
To change the operating mode:
01
•Enter the Extended Menu 1.
02
• Press SEL button as often as necessary until the CODE LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•CODE LED will turn on/off, signaling the success of the operation.
• CODE PED. |
OPENING PUSH
Activate Opening push with maximum force:
01 • Enter the Extended Menu 1.
02
•Press SEL button as often as necessary until the CODE PED LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•CODE PED LED will turn on/off, signaling the success of the operation.
Automatic Mode Functioning (LED CODE OFF):
• The first impulse transmitter/pushbutton triggers the opening of the gate.
• The second impulse (after gate fully opens) triggers the closing of the gate.
• If you press the command during opening or closing maneuvers, the gate inverts the
direction until the new direction is completed.
Step by Step Mode Functioning (LED CODE ON):
For each order you send from a remote control/push button, the control board will have
a behave like: open-stop-close-stop-open - (...). The control board is supplied by the
manufacturer with the step by step active.
Note • If T. PAUSA is active (lit) and stops the gate during opening, it will be stopped until the
pause time has elapsed, to close automatically. If you stop during closing, it will only re-open
when you receive a new order.
Step By Step Automatic
With this function enabled, the control unit provides more power at the initial opening time,
so that the motor can overcome the lock and open normally.
Factory setting: Opening push = OFF Function ON Function OFF
Factory setting: Automatic Operation
A B
ENEN
Factory setting: PGM à distância = OFF
Factory setting: Closing push = OFF
EXTENDED MENU 
. PROGRAMMING
• T. MOT. |
CLOSING PUSH
Activate Closing Push with maximum force:
01
•Enter the Extended Menu 1.
02
•Press SEL button as often as necessary until the T. MOT. LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•T. MOT. LED will turn on/off, signaling the success of the operation.
To activate the Closing Push with the force set on the trimmer VR1:
01
•Enter the Extended Menu 1.
02
•Press SEL button as often as necessary until the T. MOT. LED starts to flash.
03
•Press the SEL button until the T. MOT LED flashes quickly.
04
•Press SET to activate.
05
•T. MOT. LED will turn on/off, signaling the success of the operation.
• T. MOT. PED. |
FOLLOW ME
Set follow me:
01
•Enter the Extended Menu 1.
02
•Press SEL button the times necessary until the T. MOT. PED. LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
The T. MOT. PED LED will turn on/off, signaling the success of the operation.
With the closing push function, the control board case is programmed with deceleration,
will add 1 second acting at full motor power, so that the gate can overcome the lock.
Function ON Function OFF
With this function enabled, the control pa-nel will automatically close 5 seconds after the
photocells detect the passage of some user/object.
NOTE: To use this function, you must activa-te the Pause Time in the Main Menu.
Factory setting: Follow Me = OFF Function ON Function OFF
. PROGRAMMING
EXTENDED MENU 
The control panel has an EXTENSIVE MENU 2, with more functions for programming.
To access the extended menu 2 options proceed as follows:
01 • Enter the extended menu 1 (see page 8A).
02 • Press continuously the SET button for 5 seconds and the T. PAUSA and T. RIT. ANTE LEDs will flash si-
multaneously.
03 • You have 30 seconds to select functions from the extended menu 2 (using the SEL and SET button), and
after this time the control board returns to the main menu.
EXTENDED MENU 2
LED LED OFF LED ON
• TIPO MOT. PGM from distance = OFF PGM from distance = ON
• AUTO PGM DS Photocell test = OFF DS Photocell test = ON
• CODE Pre-Intermitt. and Court Light = OFF Pre-Intermitt. and Court Light = ON
• CODE PED. Pause time light = OFF Light Time Pause = ON
• T. MOT. PUL = Total | PED = Pedestrian PUL = Total | PED = Aux cell
• T. MOT. PED. PUL = Total | PED = Pedestrian PUL = Open | PED = Close
• T. PAUSA Simultaneous ON/OFF flashing
• T. RIT. ANTE Simultaneous ON/OFF flashing
• TIPO MOT. |
PROGRAMMING TRANSMITTERS AT DISTANCE
Enable/Disable function:
01
•Enter the Extended Menu 2.
02
•Press SEL button the times necessary until the TIPO MOT. LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•TIPO MOT. LED will turn on/off, signaling the success of the operation.
Programming transmitter at distance:
01
•Press the key of a previously stored command for 10 seconds.
02
•The TIPO MOT. LED of the Main Menu will flash.
03
•Press the new transmitter key for 1 second, to program it.
04
•The flashlight will flash confirming the success of the operation.
This function allows you to program new transmitters without access directly to the control
board, by using another already programmed transmitter to open the memory.
Function ON Function OFF
Activate Opening Push with the force set on the potentiometer:
01
•Enter the Extended Menu 1.
02
•Press SEL button as often as necessary until the CODE PED LED starts to flash.
03
•Press the SEL button until the CODE PED LED flashes quickly.
04 • Press the SET key (1 second) to activate / deactivate the function.
05
•CODE PED LED will turn on/off, signaling the success of the operation.
A B
ENEN
Factory setting: Pause time light = OFF
Factory setting: PUL = Total | PED = Pedestrian
Factory setting: PUL = Total | PED = Pedestrian
Factory setting: DS Photocell test = OFF
Factory setting: Pre-Intermitt. and Court Light = OFF
. PROGRAMMING
EXTENDED MENU 
• CODE |
PREINTERMITTENCE / COURTESY LIGHT
• CODE PED |
FLASHLIGHT PAUSED
Enable Pre-fire (LED on):
01 • Enter the Extended Menu 2.
02 • Press SEL button the times necessary until the CODE LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
Turn on the Courtesy Light (LED lit):
01 • Enter the Extended Menu 2.
02 • Press SEL button the times necessary until the CODE LED starts to flash.
03
• Press the SEL button one more time and the CODE LED will flash rapidly.
04
•Press the SET key (1 second) to activate / deactivate the function.
01 • Enter the Extended Menu 2.
02 • Press the SEL button until the T. PAUSA LED and the LED CODE PED. before flashing.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•CODE PED LED will turn on/off, signaling the success of the operation.
01 • Enter the Extended Menu 2.
02 • Press SEL button the times necessary until the AUTO PGM LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•AUTO PGM LED will turn on/off, signaling the success of the operation.
If you do not connect photocells to the DS input, you must make a shunt between COM and
DS (09 and 11) and this Photocell Test must be deactivated.
Function ON Function OFF
Pre-blinkingoperation:The Blinking LAMP outputisactivated3 seconds before the automatism
starts any movement.
Courtesy Light Operation: The Intermittent LAMP output is activated whenever it receives an
opening order, and remains active for 3 minutes.
Function ON Function OFF
With this option enabled, whenever the engine is in standby time the 24V output for firefly
will remain on.
Function ON Function OFF
• AUTO PGM |
PHOTOCELL TEST DS CONNECTION
With this function, you can test the connection of photocells. With the function on, whene-
ver you receive an opening order, there is a momentary interruption in powering the photo-
cells and a pulse is sent to test the connection.
If it does not work in this way, there is a problem in the connection between the photocells
and the control panel.
EXTENDED MENU 
. PROGRAMMING
• T. MOT. |
FUNC. PED  PEDESTRIAN OPENING OR AUX PHOTOCELL
01 • Enter the Extended Menu 2.
02 • Press SEL button the times necessary until the LED T. MOT starts to flash.
03 • If you want to set this input with the AUX1 Cell, press the SET key once to activate.
If you want to set this input as the AUX2 cell, press the SEL key again to the T. MOT LED blink
rapidly, and then press SET once to activate.
04
•T. MOT LED will turn on/off, signaling the success of the operation.
When enabled, this function changes the operation of the PED input for auxiliary photocell
use. The LED T. MOT lit indicates that the auxiliary input for photocells is selected, the LED
off indicates that the PED / DS input is being selected (this circuit becomes a N.C. circuit).
Function ON Function OFF
• T. MOT. PED. |
FUNC. PULL AND PED  TOTAL/PEDESTRIAN OR OPEN/CLOSE
01 • Enter the Extended Menu 2.
02 • Press SEL button the times necessary until the T. MOT. PED. LED starts to flash.
03
•Press the SET key (1 second) to activate / deactivate the function.
04
•T. MOT PED LED will turn on/off, signaling the success of the operation.
When activated, this function changes the operation of the PUL input for the release button
and the PED input for the release button.
The T. MOT. PED on indicates that the PUL function is set for opening and PED
for closing. The LED off indicates that it is factory set.
PUL = Open, PED = Close (LED light) / PUL = PUL and PED = PED (LED off)
Function ON Function OFF
A B
ENEN
. PROGRAMMING
EXTENDED MENU 
RESET OF CONTROL BOARD
To restore factory settings, press SEL and SET keys at the same time until all LEDs light up.
When the keys are released they will go off, the operation will be completed.
Extensive menu 3 allows you to set the speed of the motor slowdown.
Factory setting: Level 3
Access Extension Menu 3:
01
•Access the extended menu 1 (page 8A).
02
•Access the extended menu 2 (page 9B).
03 • Press SET continuously for 5 seconds and the T. PAUSA and T. RIT ANTE LED will flash
alternately. They then blink simultaneously and have 30 seconds to set the speed.
Change speed level:
In the images you can identify the LEDs that light up and flash on each level:
LIGHT UP
BLINK
Use the SEL key to toggle between the
6 levels.
Example: if you select level 3, the TIPO
MOT LED will and AUTO PGM will light
up and the CODE LED will flash.
Use the SET key to confirm the level
you want.
The LEDs of the selected level will
remain on for 30 seconds.
LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL

12/20V MOT.1 MOT.2 PUL PED BL DS FA1 FC1 FA2 FC2+V
BATT
+12V- LAMP
+ - SERR.
+ - L.SPIA
+12V-
S.P.
+
1,6Ah
10Ah
F1
F2
+12V-*
+24V-
POWER
12V/24V CONTACT
POWER
12V/24V
COM NC
POWER
12V/24V CONTACT
POWER
12V/24V
COM NC
POWER
12V/24V CONTACT
POWER
12V/24V
COM NC
POWER
12V/24V CONTACT
POWER
12V/24V
COM NC
POWER
12V/24V CONTACT
POWER
12V/24V
COM NC
FUSE
DS
FA1
FC1
FA2
FC2
230Vac: 2Ah
115Vac: 3Ah
N0
N0
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 1881 2 3 4 5 6 7 9 10 118
CN1 CN2
EN
. CONNECTION SCHEME
COMPONENT'S CONNECTION TO THE CONTROL BOARD
Emergency
STOP button (NC)
12VDC
3W Máx.
Antenna
Complete
Opening
Partial
Opening
Fechadura
elétrica
24VDC
12W Máx.
Transformer:
230Vacor 110Vac
50/60Hz
120W Máx.
Solar Panel
Flashing light
24VDC
4W Máx.
Motor 1
230Vac or 110Vac
Sets of
photocells
Motor 2
Motor 2
Motor 1
When the photocells circuits are not being used,you must close
them with a bridge (shunt) on the control board.
11
∑
14 - 14
∑
12 - 14
∑
13 - 14
∑
15 - 14
∑
16)
When the STOP button is not being used, you must close the
hem with a bridge (shunt) on the control board.
(9
∑
10)
PHOTOCELLS DIAGRAM
POWER/SPEED SENSITIVITY
Set of
photocells
FC1
Set of
photocells
FA2
Set of
photocells
FC2
Set of
photocells
DS or FA1
CN2 (4)
Maximum output of 125mAh.
Power Supply
* Only for TELICA motors
 EN
. TROUBLESHOOTING
INSTRUCTIONS FOR FINAL CONSUMERS/TECHNICIANS
Anomaly Procedure Behavior Procedure II Discovering the origin of the problem
• Motor
doesn’t work • Make sure you
have 110/230V power
supply connected to
automation and if it
is working properly.
• Still not working • Consult a qualified
MOTORLINE technician. 1 • Open control board and check if it has 110/230V power supply;
2 • Check the control board input fuses;
3 • Disconnect the motors from the control board and test them connected directly to a 12 / 24V battery to find out if it is malfunctioning.
4 • If the motor works, the problem is on the control board. Pull it out and send it to the MOTORLINE technical services for diagnosis;
5 • If the motor doesn’t work, remove it from installation site and send to the MOTORLINE technical services for diagnosis.
• Motor
doesn’t move
but makes
noise
• Unlock motor and
move the roller
by hand to check
for mechanical
problems.
• Encountered
problems? • Consult an experienced
expert.  • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out what is
the problem.
• The gate moves
easily? • Consult a qualified
MOTORLINE technician.  • If the motor works, the problem is on the control board. Pull it out and send it to the technical services for diagnosis;
 • If the motor doesn’t work, remove it from installation site and send to the technical services for diagnosis.
• Motor
opens but
doesn’t close
• Unlock motor and
move the roller
by hand to closed
position. Block the
motor again and turn
off power supply for
5 seconds. Reconnect
it and send order
to open gate using
remote control.
• Gate opened but
didn’t close again. 1 • Check if there is any
obstacle in front of the
photocells;
 • Check if any of the control
devices are stucked and
sending permanent signal to
control board;
 • Consult a qualified
MOTORLINE technician.
All control boards MOTORLINE have LEDs that easily allow to conclude which devices are with anomalies. All safety devices LEDs (Le) in normal
situations remain On. All "START" circuits LEDs in normal situations remain Off.
If LEDs devices are not all On, there is some security systems malfunction (photocells, safety edges). If "START" circuits LEDs are turn (Op and Cl),
there is a control device sending permanent signal.
A) SECURITY SYSTEMS:
 • Close the photocell circuit with shunt or disable the PHOTO function.
 • Check that the system is functional.
 • Replace it with a functional device, and check if the automation function correctly with all other devices. If you find another one defective, follow
the same steps until you find all the problems.
B) START SYSTEMS:
 • Disconnect all wires connected to the connector (PULL and PED).
 • If the LED turned OFF, try reconnecting one device at a time until you find the defective device.
NOTE:
In case procedures described in sections A) and B) don’t result, remove control board and send to the technical services for diagnosis.
• Motor
doesn’t make
complete
route
Unlock motor
and move gate
by hand to check
for mechanical
problems on the
gate.
• Encountered
problems? • Consult an experienced
expert.  • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out what is
the problem.
• The gate moves
easily? • Consult a qualified
MOTORLINE technician.  • If the motor doesn’t work, remove it from installation site and send to our MOTORLINE technical services for diagnosis.
 • If motor work well and move gate at full force during the entire course, the problem is from controller. Set force using trimmer on the board.
Make a new working time programming , giving suffient time for opening and closing with appropriate force.
 • If this doesn’t work, remove control unit and send it to MOTORLINE technical services services.
NOTA:
Setting force of the controller should be sufficient to make the gate open and close without stopping, but should stop and invert with a little
effort from a person. In case of safety systems failure, the gate shall never cause physical damaged to obstacles (vehicles, people, etc.).

This manual suits for next models

1

Other Motorline Control Unit manuals

Motorline MC6 User manual

Motorline

Motorline MC6 User manual

Motorline MC11 Use and care manual

Motorline

Motorline MC11 Use and care manual

Motorline MC2 User manual

Motorline

Motorline MC2 User manual

Motorline MC75 Use and care manual

Motorline

Motorline MC75 Use and care manual

Motorline MC1 User manual

Motorline

Motorline MC1 User manual

Motorline MC15SC Instruction Manual

Motorline

Motorline MC15SC Instruction Manual

Motorline MC7 User manual

Motorline

Motorline MC7 User manual

Motorline MC2 User manual

Motorline

Motorline MC2 User manual

Motorline MC2 Use and care manual

Motorline

Motorline MC2 Use and care manual

Popular Control Unit manuals by other brands

OSF POOLcontrol-45 exclusiv Installation and operating instructions

OSF

OSF POOLcontrol-45 exclusiv Installation and operating instructions

Teletek electronics ARGUS Installation, programming, and  user's manual

Teletek electronics

Teletek electronics ARGUS Installation, programming, and user's manual

L&S SMART 4 quick start guide

L&S

L&S SMART 4 quick start guide

HKC APL-5 Series Installation, operation & maintenance manual

HKC

HKC APL-5 Series Installation, operation & maintenance manual

M-system 61F instruction manual

M-system

M-system 61F instruction manual

STC 4V130E-430E Series INSTALLATION PROCEDURE

STC

STC 4V130E-430E Series INSTALLATION PROCEDURE

TECSYSTEM T119 DIN instruction manual

TECSYSTEM

TECSYSTEM T119 DIN instruction manual

PR electronics 9203 Series Safety manual

PR electronics

PR electronics 9203 Series Safety manual

Grundfos ALPHA1 B instructions

Grundfos

Grundfos ALPHA1 B instructions

ValvTechnologies V1 Series Installation and Operations Maintenance Manual

ValvTechnologies

ValvTechnologies V1 Series Installation and Operations Maintenance Manual

Volth ARGO HYTOS SD3E2X-C2 S5 Series operating instructions

Volth

Volth ARGO HYTOS SD3E2X-C2 S5 Series operating instructions

AUDEIA CU402 user manual

AUDEIA

AUDEIA CU402 user manual

Frico CFR1R Instruction booklet

Frico

Frico CFR1R Instruction booklet

Mitsubishi Wi-Fi Control installation guide

Mitsubishi

Mitsubishi Wi-Fi Control installation guide

Siemens SIMATIC S7 300 PLC Getting started

Siemens

Siemens SIMATIC S7 300 PLC Getting started

Agilent Technologies 4890 installation guide

Agilent Technologies

Agilent Technologies 4890 installation guide

Allmatic BAXS900 manual

Allmatic

Allmatic BAXS900 manual

CAME Z Series quick guide

CAME

CAME Z Series quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.