Motorline MC52 Instruction Manual

V+ LO LS LE LA
B GRY V+
26 27 28 29 30
MENU UP
CMD DW
v3.3
REV. 01/2022
MC52
EN
USER/INSTALLER MANUAL
EN

1
1B
4A
4A
4B
5
6A
13B
13A
6B
14
8B
10A
7B
9B
11A
7A
9A
10B
8A
10B
11B
12A
12B
EN
00. CONTENT 01. SAFETY INSTRUCTIONS
INDEX
TECHNICAL SPECIFICATIONS
INSTALLATION MAP
BASE INSTALLATION PROCESS
MOTOR A V/V
PROGRAMMING AND DELETE REMOTE CONTROLS
FINAL CONSUMERS INSTRUCTIONS AND SPECIALIZED INSTALLERS
E MENUS
P MENUS
DISPLAY INDICATIONS
LEDs
CONNECTORS
. SAFETY INSTRUCTIONS
. THE CONTROL BOARD
. INSTALLATION
. COMPONENTS TEST
. PROGRAMMING
. TROUBLESHOOTING
P - P
P - P
P - P
E - E - E
P - P
P
P
E
E - E
E - E
E - E
. DISPLAY
. PROGRAMMING "P"
. PROGRAMMING "E"

2EN
01. SAFETY INSTRUCTIONS

3EN
01. SAFETY INSTRUCTIONS

4A 4B
N L
1 2 3 4 5
COMABLAMP FE
6 7 8 9 10 11 12 13
COMAB FE L+V+ LO
14 15 16 17 18
LELS LA ANT
19 20 21 22 23 24 25
V+ LO LS LE LA
B GRY V+
26 27 28 29 30
ENEN
02. CONTROL BOARD 02. CONTROL BOARD
TECHNICAL SPECIFICATIONS
LEDs
CONNECTORS
The MC52 is a single-phase control board with built-in radio control system designed for the
automation of swing gates.
LEDs
V+ • LED On indicates that the line for V+ output is OK.
LS • LED On when pedestrian opening is active.
LO • LED On when full opening is active.
LA • LED on when the photocell is active (P6 active) or the ↓ LA circuit is closed.
LE • LED on when the photocells are active (P5 active) or the ↓ LE circuit is closed.
110V version 230V version
• Power Supply 110Vac 60Hz 230Vac 50-60Hz
• Flashing light’s output 110Vac 60Hz 500W max. 230Vac 50Hz 500W max.
• RGB Flashing light’s output 24Vdc 100mA max.
• Motor’s output 110Vac 60Hz 500W max. 230Vac 50-60Hz 500W max.
• Auxiliary accessories output 24Vdc 8W max.
• Security and BT Remote controls 24Vdc
• Working temperature -25°C to +55°C
• Incorporated Radio Receptor 433,92 Mhz
• OP Remote controls 12bits or Rolling Code
• Maximum Memory Capacity 100 (full opening) - 100 (pedestrian opening)
• Control board Dimensions 125mm x 140mm
Make sure which version you are using (110Vac or 230Vac).
CN1
01 • Grounding connection
02 • Grounding connection
03 • Grounding connection
04 • 110/230Vac (Neutral) (N) line input
05 • 110/230Vac (Phase) (L) line input 110/230Vac Power Supply
06 • Flashing light Output - 110/230Vac 500W
07 • Flashing light Output - 110/230Vac 500W
Courtesy light or Flashing light: This output
allows the connection of a courtesy light or a
Flashing light.
08 • Motor 1 Output - Opening - 110/230Vac 500W
09 • Motor 1 Output - Common - 110/230Vac 500W
10 • Motor 1 Output - Closing - 110/230Vac 500W
Motor 1
11 • Motor 2 Output - Opening - 110/230Vac 500W
12 • Motor 2 Output - Common - 110/230Vac 500W
13 • Motor 2 Output - Closing - 110/230Vac 500W
Motor 2
CN2
14 •
24Vdc 200mA max. Power supply
15 •
24Vdc 200mA max. Power supply
24Vdc Auxiliary Power Supply
16 • Electric lock Output 12/24Vdc 15W
17 • Electric lock Output 12/24Vdc 15W
Electric lock: This output allows the connection
of an electric lock.
Note • The indicated power is for 2 sec.
impulses.
18 • Total pushbutton Input (NA)
19 • Common
20 • Pedestrian pushbutton Input (NA)
Pushbuttons: This circuit allows the connection
of pushbuttons for full or pedestrian opening.
21 • Photocells 1 (NC)
22 • Common
23 • Photocells 2 (NC)
24 • Antenna
25 • GND
Safety circuits: This circuit allows the connec-
tion of photocells. Its operation depending
on the configuration of the P5 and P6 menus
(check page 9A).
Antenna
CN3
26 • Output Y (GND)
27 • Output R (GND)
28 • Output B (GND)
29 • Output G (GND)
30 •
Auxiliary output for Flashing light or 24Vdc LED
Open collector for the management of auxiliary
functions:
Output Y is activated in intermittent mode, only
with the gate closed.
Output R is activated in intermittent mode, only
in the closing phase.
Output B is activated in intermittent mode, only
during the pause time.
Output G is activated in intermittent mode, only
during the opening phase.

5
L N
~ ~
~ ~
~ ~
TX
+
1 2
-
RX
+-COM NC/
NO
1 2 3 4
TX
+
1 2
-
RX
+-COM NC/
NO
1 2 3 4
V+ LO LS LE LA
MENU UP
CMD DW
24 25
22 2320 21
18 19
16 17
14 15
1211 13
2928
2726 30
98 1021 3
L+V+ LO LELS LA
6 74 5
N L COMAB
LAMP FE COMAB FE
B GRY V+
EN
. INSTALLATION
INSTALLATION MAP
Exterior Photocells* Interior Photocells*
Electric Lock
Pushbutton or
Key Selector
Pushbutton or
Key Selector
or
or
Flashing light
Fuse
63mA
Fuse 8A
Antenna
Motor 1
Motor 2
• The use of capacitors
depends on the type of motor
to be installed. Check in the motor
manual, if it is necessary to place the
capacitors, as shown in the diagram.
• Motor opens first than Motor .
• Motor closes first than Motor .
NOTE • When programming, the first
operation of each leaf must be the
opening operation. In case of closing
operation, change the brown and
black wires of this motor.
•
The photocell safety circuits are supplied by
default deactivated (no shunt required).
To activate them go to menu P and P.
• If you do not press any button for sec. the
control board will return to standby.
If you activate the EL option in the E5 menu,
the electric lock must not be powered by the
control board. To do this, use an external power
supply to power the electric lock.

6A 6B
ENEN
. INSTALLATION
BASE INSTALLATION PROCESS
01 • Connect all accessories according to the connections diagram (page 5).
02 • Connect the control board to a 230V power supply (terminals 4 and 5 - CN1).
03 • Check if the gate movement is the same as shown on the display.
04 • Make a course programming - menu P0 (página 8A).
05 • If necessary, adjust the deceleration time of the gate at opening and closing - menu P1
(page 8A).
06 • Adjust the gate force - menu P2 (page 8B).
07 • Re-program the course - menu P0 (page 8A).
08 • Enable or disable the use of Photocells in menu P5 and P6 (page 9A).
09 • Program a remote control (page 6B).
The control board is now fully configured!
Check the pages of the menu programming if you want to configure other features of the
Control board.
02 • Select (SU)
using ↑ ↓.
05 • Press cmd for 3 sec
and the location will be
empty.
The display will blink
and the position will
be free.
01 • Press the
cmd button for
3 sec.
Remote controls programming for total opening.
Remote controls programming for pedestrian opening.
02 • Select (SU)
using ↑ ↓.
03 • Press cmd
once to confirm. 04 • Use ↓↑ to
select the remote
control location
you want to
delete.
04 • The first free
position appears.
05 • Press the remote
control button you want
to program. The display
will blink and move to the
next free location.
03 • Press cmd
once to confirm.
01 • Press the
cmd button for
3 sec.
• PROGRAMMING REMOTE CONTROL
• ERASE ALL THE REMOTE CONTROL
• ERASE REMOTE CONTROL
. PROGRAMMING
PROGRAMMING AND DELETE REMOTE CONTROLS
The installation process assumes that the gate already has mechanical or electrical
limit switches installed.
• If you do not press any button for 10 sec.
the control board will return to standby.
02 • The display will show SU.
03 • SU will flash.
04 • LU flashes, confirming that all remote
control have been deleted.
01 • Press the cmd button for 10 sec.

7A 7B
ENEN
. PROGRAMMING
P MENUS
. PROGRAMMING
E MENUS
• We can only enter programming with the gate stopped (electrically).
• To access the P menu press the MENU button for 3 sec.
• Use ↓↑ to navigate through the menus.
• Press MENU when you want to confirm access to a menu.
• Press ↓↑ simultaneously to exit programming.
MENU FUNCTION MAX. MIN.
PROGRAMMABLE STATE FACTORY
VALUE PAGE
Course Programming -
Manual Programming
-8A
1 motor
2 motors
Deceleration time adjustment
Opening deceleration (Leaf )
8A
Closing deceleration (Leaf )
Opening deceleration (Leaf )
Closing deceleration (Leaf )
Force adjustment Force adjustment 8B
Pedestrian Course time Time adjustment in pedestrian course B
Pause time and gates delay
Total pause time
8B
Pedestrian pause time
Opening gates delay
Closing gates delay
Photocells programming
Disables
Ative
9A
In Opening
In Closing
Invert
Stop
Invert 2 sec. and Stop
Photocells programming
Disables
Ative
9A
In Opening
In Closing
Invert
Stop
Invert 2 sec. and Stop
Operating logic
Automatic mode function
9B
Step by step mode function
Condominium mode function
Flashing light
Flashing (opening and closing)
9B
Step by step mode function
Courtesy light
Remote programming Distance PGM OFF 9B
Distance PGM ON
0 1
min. máx.
0 2
min. máx.
0 2
min. máx.
0 2
min. máx.
0 1
min. máx.
0 1
min. máx.
0 2
min. máx.
0 1
min. máx.
0 1
min. máx.
25s
0s
min. máx.
25s
0s
min. máx.
99s
0s
min. máx.
99s
0s
min. máx.
99s
0s
min. máx.
25s
0s
min. máx.
0 9
min. máx.
MENU FUNCTION MAX. MIN.
PROGRAMMABLE STATE FACTORY
VALUE PAGE
Present Man
Deactivates present man
Activates present man 10A
Disables push buttons mode
Activates push buttons mode
Soft start Deactivates Soft start 10A
Activates Soft start
Courtesy light time Courtesy light time adjustment (minutes) 10A
Follow me -
Deactivates follow me
Follow me does not act when the gate is opening. It
only works when it is open. 10A
Follow me acts when the gate is open and when
it is open.
Course time adjustment
Opening course time (minutes) - Leaf
10B
Opening course time (seconds) - Leaf
Closing course time (minutes) - Leaf
Closing course time (seconds) - Leaf
Opening course time (minutes) - Leaf
Opening course time (seconds) - Leaf
Closing course time (minutes) - Leaf
Closing course time (seconds) - Leaf
Brake/Lock/Strokes
Disables electronic brake
Active electronic brake
10B
Activates electric lock on opening sec.
Activates electric lock whenever moving
Disables opening push
Active opening push
Disables closing push
Active closing push
Deceleration Speed Deceleration Speed adjustment 10B
Manuevers counter -Shows the number of maneuvers -10B
Reset - Restore factory
settings
Deactivated 11A
Reset activated
RGB Output -Continued output 11A
Intermittent output
REMOTE CONTROL
Remote control programming for total opening. B
Remote control programming for pedestrian opening. B
0 1
min. máx.
0 1
min. máx.
99m
0m
min. máx.
0 1
min. máx.
0 1
min. máx.
0 9
min. máx.
3m
0m
min. máx.
3m
0m
min. máx.
3m
0m
min. máx.
3m
0m
min. máx.
59s
0s
min. máx.
59s
0s
min. máx.
59s
0s
min. máx.
59s
0s
min. máx.

8A 8B
ENEN
DIRECTION OF
DISPLAY ROTATION COURSE PROGRAMMING OF TWO MOTORS
Normal rotation - leaf 1 starts opening (normal speed)
Slow rotation - leaf 1 goes into opening slowdown (slowdown speed)
Normal rotation – leaf 1 stops and leaf 2 starts opening (normal speed)
Slow rotation - leaf 2 goes into opening slowdown (slowdown speed)
Normal rotation – leaf 2 stops and starts closing (normal speed)
Slow rotation - leaf 2 goes into closing speed (slowdown speed)
Normal rotation - leaf 2 stops and leaf 1 starts opening (normal speed)
Slow rotation - leaf 1 goes into closing slowdown (slowdown speed)
DIRECTION OF
DISPLAY ROTATION COURSE PROGRAMMING OF ONE MOTOR PEDESTRIAN
Normal rotation - leaf starts opening (normal speed)
Slow rotation - the leaf goes into opening slowdown (slowdown speed)
Normal rotation - the leaf stops and starts closing (normal speed)
Slow rotation - the leaf goes into closing slowdown (slowdown speed)
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear . Use UP or DW to navigate the parameters.
04 • Press MENU to edit the chosen parameter value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
COURSE PROGRAMMING
. PROGRAMMING "P"
You can use the remote instead of the MENU button.
Whenever a leaf touches a stop, wait 1 second before clicking on the MENU.
To exit the programming menus, press the UP and DOWN button simultaneously.
Whenever there is a reversal of the direction of travel, the preset deceleration time is
increased by 2 sec. up to 25 sec. maximum.
Course Manual Programming
This menu allows you to manually set the course of
the leaf/leaves.
Number of Motors
Allows you to define the number of motors connected
to the control board
(Default value NA) (Default value 02)
COURSE PROGRAMMING
FORCE ADJUSTMENT
DECELERATION TIME ADJUSTMENT
. PROGRAMMING "P"
. PROGRAMMING "P"
. PROGRAMMING "P"
This menu allows you to set the deceleration time of each leaf at opening and closing.
Slowing down on opening leaf 1
It allows to define the time that the gate will act with
slowdown in the opening.
Slowing down on closing leaf 1
It allows to define the time that the gate will act with
slowdown in the closing.
Slowing down on opening leaf 2
It allows to define the time that the gate will act with
slowdown in the opening.
Slowing down on closing leaf 2
It allows to define the time that the gate will act with
slowdown in the closing.
(Default value 3)
min. max.
0s
25s
This menu allows you to set the force that is injected into the motor when it moves at normal speed.
The default value is 4.
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
Manual programming 2 arms:
01 • Press MENU for 2 sec. until appears.
02 • Press MENU once until appears.
03 • Press MENU (or remote control) to start programming the opening time of leaf 1.
04 • Press MENU to start the opening slowdown of leaf 1. Repeat these two steps (03 and
04) for leaf 2.
05 • Press MENU to start programming the closing time of leaf 2.
06 • Press MENU to start the closing slowdown of leaf 2. Repeat these two steps (05 and
06) for leaf 1.
07 • Press MENU once to display , leaf 1 stops.
08 • Use UP and DW to display to exit programming mode.
09 • Use UP and DW to stay in Standby.
Manual programming 1 arm:
01 • Press MENU for 2 sec. until appears.
02 • Press MENU once until appears.
03 • Press MENU (or remote control) to start programming the opening time of leaf.
04 • Press MENU to start the opening slowdown of the leaf.
05 • Press MENU to stop the leaf and start programming the closing time.
06 • Press MENU to start the closing slowdown of the leaf.
07 • Press MENU once to display , leaf 1 stops.
08 • Use UP and DW to display to exit programming mode.
09 • Use UP and DW to stay in Standby.

9A 9B
ENEN
PEDESTRIAN COURSE TIME
PAUSE TIME AND GATES DELAY
PHOTOCELLS PROGRAMMING
PHOTOCELLS PROGRAMMING
Allows you to set the pedestrian course time.
The default value is 10.
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu the value set by the factory will appear.
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
Full closing pause time
adjustment
This menu allows
you to set the total
opening pause time.
Pedestrian closing pause
time adjustment
Allows you to set the
pause time at the
pedestrian opening.
Gate delay in closing
Allows you to set the
delay time for closing
leaf 1 relative to leaf 2.
Gate delay in opening
Allows you to set the
delay time for opening
leaf 2 relative to leaf 1.
(Default value 0) (Default value 0) (Default value 2) (Default value 2)
99s
min. max.
0s
99s
min. max.
0s
0s
min. max.
25s
0s
min. max.
25s
When the values are at zero, there is no automatic closing.
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear . Use UP or DW to navigate the parameters.
04 • Press MENU to edit the chosen parameter value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear . Use UP or DW to navigate the parameters.
04 • Press MENU to edit the chosen parameter value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear . Use UP or DW to navigate the parameters.
04 • Press MENU to edit the chosen parameter value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
00 (deactivate)
01 (active)
Enable or disable security
entry.
00 (photocells in opening)
01 (photocells in closing)
Define if this security will act
on opening or closing.
00 (the movement of the gate is
reversed)
01 (gate movement stops and
resumes 5 sec after security is
disabled)
02 (the movement of the gate
reverses for 2 seconds and stops)
Define the behavior that the gate
will have when this security is
activated.
(Default value 0)
00 (deactivate)
01 (active)
Enable or disable security
entry.
00 (photocells in opening)
01 (photocells in closing)
Define if this security will act
on opening or closing.
00 (the movement of the gate is
reversed)
01 (gate movement stops and
resumes 5 sec after security is
disabled)
02 (the movement of the gate
reverses for 2 seconds and stops)
Define the behavior that the gate
will have when this security is
activated.
(Default value 0)
. PROGRAMMING "P"
. PROGRAMMING "P"
. PROGRAMMING "P"
. PROGRAMMING "P"

10A 10B
ENEN
Remote Programming Operation (PGM ON):
• Press the keys indicated in the image simultaneously for 10 seconds
and the flashing light will flash (the 1st free position appears in the
display).
Each time you store 1 command, the control board will exit remote
programming. If you want to memorize more commands, you will
always have to repeat the process of pressing the command keys
simultaneously for 10 seconds for each new command.
REMOTE PROGRAMMING
PRESENT MAN
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
(Default value 00)
This menu allows you to enable/disable remote programming.
00 (deactivate)
01 (active)
Enable or disable present man.
Note • With active present man RF remote con-
trols do not work.
00 (deactivate)
01 (active)
Allows you to activate or deactivate the
pushbutton mode.
(Default value 00)
LS LO
01
ACTIVE Full opening Full
closning
00
DEACTIVATE Pedestrian
maneuvers Total
maneuvers
01 • Press MENU for 10 sec. until it appears .
02 • Press Menu will appear . Use UP or DW to navigate the parameters.
03 • Press MENU to edit the chosen parameter value.
04 • The factory set time appears. Use UP and DW to change the value.
05 • Press MENU to save the new value.
. PROGRAMMING "E"
. PROGRAMMING "P"
. PROGRAMMING "P"
. PROGRAMMING "P"
OPERATING LOGIC
FLASHING LIGHT
This menu allows to set the operating logic of the automation.
Automatic Mode
Whenever there is an order the
movement is reversed.
Step by step mode
1st impulse - OPEN
2nd impulse - STOP
3rd impulse - CLOSE
4th impulse - STOP
If it is fully open and timed, it closes.
Condominium Mode
Does not respond to orders
during opening and break time.
(Default value 00)
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 2 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
Flashing
(opening and closing)
During the opening/closing
movement of the gate, the flash-
ing light will work intermittently.
Step by step mode the opening
and closing movement, the
flashing light is permanently
on.
Courtesy light
The light will stay on for the
time set in the E2 menu.
(Default value 00)
This menu allows you to set the operation mode of the flashing light (LAMP).

11A 11B
ENEN
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
SOFT START COURSE TIME ADJUSTMENT
Enables or disables the soft start. With the soft start function activated, at each start of move-
ment the control board will control the motor start, increasing the speed gradually in the first
second of operation.
The default value is 0(deactivated).
This menu allows you to adjust the courtesy light time for all positions of the gate (closed,
opened and stopped). The default value is 0 (Courtesy light deactivated)
COURTESY LIGHT TIME
BRAKE/LOCK/PUSH
FOLLOW ME
This parameter is only activated if option 2 is selected in P8.
Allows you to activate the Follow me option. With this option activated, the control board, when
in the open position or in opening, gives a closing order of 5 sec. after the safety device detects
the passage of an object / user.
00 function disabled
01 function activated after opening
02 function activated on opening
(Default value 00)
Leaf 1
Opening courses time
(minutes) Opening courses time
(seconds) Closing courses time
(minutes) Closing courses time
(seconds)
(Default value 0) (Default value 15) (Default value 0) (Default value 15)
Leaf 2
Opening courses time
(minutes) Opening courses time
(seconds) Closing courses time
(minutes) Closing courses time
(seconds)
(Default value 0) (Default value 15) (Default value 0) (Default value15)
It allows to adjust the working time for the opening and closing courses of the two leafs.
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear . Use UP or DW to navigate the parameters.
04 • Press MENU to edit the chosen parameter value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
00 (disables electronic
brake)
01 (activates electronic
brake)
Allows you to activate the
electronic brake.
00 (active lock on
opening 2 sec.)
01 (activates lock
whenever in motion)
Allows you to select the
lock's operating mode.
The default value is
0 (2 second pulse on
opening).
Note: If you select option
2, you must take into
account the maximum
current value provided by
the control board.
00 (disable opening push)
01 (active opening push)
Allows you to activate the
opening push (ram).
00 (disables closing push)
01 (active closing push)
Allows you to activate the
closing stroke.
(Default value 0) (Default value 0) (Default value 0) (Default value 0)
It allows to activate or deactivate the functions of the electronic brake, the lock's
operating mode and to activate or deactivate pushes on opening and closing.
. PROGRAMMING "E"
. PROGRAMMING "E"
. PROGRAMMING "E"
. PROGRAMMING "E"
. PROGRAMMING "E"

12A 12B
ENEN
RESET - RESET FACTORY VALUES
RGB OUTPUT
MANUEVERS COUNTER
. PROGRAMMING "E"
. PROGRAMMING "E"
. PROGRAMMING "E". PROGRAMMING "E"
. PROGRAMMING "E"
. PROGRAMMING "E"
1º 2º
display flashes display flashes
04 • The maneuvers count is displayed in the following order (example: 130 371):
05 • E8 appears.
3º dozens
2º thousands1º hundred thousand
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear .
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
This menu allows you to reset to factory defaults.
The default value is 0 (deactivated).
This menu allows you to set the operation mode of RGB outputs.
The default value is 0 (continuous output).
BRAKE/LOCK/PUSH
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu will appear . Use UP or DW to navigate the parameters.
04 • Press MENU to edit the chosen parameter value.
05 • The factory set time appears. Use UP and DW to change the value.
06 • Press MENU to save the new value.
01 • Press MENU for 10 sec. until it appears .
02 • Use UP until appears .
03 • Press Menu the value set by the factory will appear.
04 • Press MENU to edit the value.
05 • Use UP and DW to change the value.
06 • Press MENU to save the new value.
This menu allows you to adjust the deceleration speed.
The higher the slowdown level, the faster the slowdown.
The default value is 4.
DECELERATION SPEED
MANUEVERS COUNTER
This menu allows you to view the number of maneuvers performed.
(complete maneuver means opening and closing).
Resetting the control board does not clear the maneuver count.
Example: 13456 maneuvers
01- Hundred thousand / 34- Thousands / 56- Dozens
01 • Press MENU for
10 secondes. 02 • E0 appears.
Press UP until
appears E7.
03 • Press MENU.

13A 13B
1
2
3
2
ENEN
To detect if the problem is in the control board or in the motor, sometimes it's necessary to
conduct tests with a direct connection to a V/V power supply.
For this, it's necessary to interpose a capacitor on the connection so that the motor can work
(check the capacitor type to be used in the product's manual). In the below diagram is shown
how this connection must be made and how to merge the different component wires.
01 • Connect the power wires to the terminal as shown below.
02 • Connect the automation wires to the terminal, interleaving a capacitor into the opening
and closing wires.
03 • After these connections are complete, connect to a 230V/110V power socket, depending
on the motor/control board being tested.
NOTES:
• To perform the tests you don't need to remove the automatism from it's place, because this way you
can understand if the automatism, directly connected to the power, can function correctly.
• A new capacitor should be used during this test to ensure that the problem is not in the capacitor.
. COMPONENTS TEST
V/V MOTOR
IN STOP POSITION, FULLY OPENED
IN STOP POSITION, MIDDLE POSITION
IN STOP POSITION, FULLY CLOSED
TOTAL OPENING BUTTON PRESSED
PEDESTRIAN OPENING BUTTON PRESSED
CONTROL BOARD PERFOMS OPENING COURSE
CONTROL BOARD PERFOMS CLOSING COURSE
END OF OPENING COURSE TIME
END OF CLOSING COURSE TIME
ALL REMOTE CONTROLS DELETED
REMOTE CONTROL ADDED IN THE INDICATED POSITION
OBSTRUCTED PHOTOCELL
OBSTRUCTED PHOTOCELL
IN PAUSE TIME
IN PEDESTRIAN PAUSE TIME
DISPLAY INDICATIONS
. DISPLAY
All tests must be performed by qualified personnel due to serious danger associated with the
misuse of electrical systems.
The use of capacitors depends on the type of motor to be installed. Check in the
motor manual, if it is necessary to place the capacitors, as shown in the diagram.
Motor
Phase
Close Power Supply
Power Supply
AUTOMATION
COM
Open
Phase
COM
COM
Ground
Wire Capacitor
F (V) / F (V)

14 EN
Anomaly Procedure Behavior Procedure II Discovering the origin of the problem
• Motor
doesn’t
work.
• Make sure you
have power supply
connected to control
board and if it is
working properly.
• Still not working. • Consult a qualified
MOTORLINE technician.
• Motor
doesn’t
move but
makes
noise.
• Unlock motor
and move the gate
by hand to check
for mechanical
problems on the
movement.
• Is the gate stuck? • Consult a qualified gates
technician.
1 • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out what is
the problem.
• The gate moves
easily?
• Consult a qualified
MOTORLINE technician.
• Motors
open but
doesn’t
close.
• Unlock motor(s)
and move the roller
by hand to closed
position. Block
the motor again
and turn off power
supply for 5 seconds.
Reconnect it and
send order to open
gate using remote
control.
• Gate opened but
didn’t close again.
1 • Check if there is any
obstacle in front of the
photocells;
2 • Check if any of the
control devices (Key
Selector, Pushbutton, Video
Intercom, etc.) are stucked
and sending permanent
signal to control board;
3 • Consult a qualified
MOTORLINE technician.
• Motor
doesn’t
make
complete
course.
• Unlock motor
and move gate
by hand to check
for mechanical
problems on the
gate.
• Encountered
problems?
• Consult an experienced
gates expert.
1 • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out what is
the problem.
• The gate moves
easily?
• Consult a qualified
MOTORLINE technician.
1 • Open control box and check if
it has 230V power supply;
2 • Check input fuses;
3 • Disconnect motors from
control board and test them by
connecting directly to power
supply in order to find out if they
have problems (see page 11B).
4 • If the motors work, the
problem is on the control board.
Pull it out and send it to our
MOTORLINE technical services
for diagnosis;
5 • If the motors don’t work,
remove them from installation
site and send to our MOTORLINE
technical services for diagnosis.
1 • Check capacitors, testing
motor with new capacitor;
2 • If capacitors are not the
problem, disconnect motors
from control board and test them
by connecting directly to power
supply in order to find out if they
have problems (see page 11B).
3 • If the motors work, the problem
is with control board. Pull it out
and send it to our MOTORLINE
technical services for diagnosis;
4 • If the motors don’t work,
remove them from installation
site and send to our MOTORLINE
technical services for diagnosis.
1 • Check capacitors, testing with
new capacitors;
2 • If capacitors are not the
problem, disconnect motor
from control board and test it
by connecting directly to power
supply in order to find out if it is
broken;
3 • If the motor(s) doesn’t work,
remove it from installation site
and send to our MOTORLINE
technical services for diagnosis.
4 • If motor work well and move
gate at full force during the entire
course, the problem is with control
board. Set force using trimmer on
the board. Make a new working
time programming, giving suffient
time for opening and closing with
appropriate force (consult control
board manual).
5 • If this doesn’t work, remove
control board and send it to
MOTORLINE technical services.
NOTE:
Setting force of the control board
should be suficiente to make
the gate open and close without
stopping, but should stop and
invert with a little effort from a
person. In case of safety systems
failure, the gate shall never cause
physical damaged to obstacles
(vehicles, people, etc.).
All control boards MOTORLINE have LEDs that
easily allow to conclude which devices are
with anomalies. All safety devices LEDs (Le)
in normal situations remain On. All "START"
circuits LEDs in normal situations remain Off.
If LEDs devices are not all On, there is some
security systems malfunction (photocells,
safety edges). If "START" circuits LEDs are turn
(Op and Cl), there is a control device sending
permanent signal.
A) SECURITY SYSTEMS:
1 •Close with a shunt all safety systems
on the control board (check manual of the
control board in question). If the automated
system starts working normally check for
the problematic device.
2 • Remove one shunt at a time until you find
the malfunction device.
3 • Replace it for a functional device and
check if the motor works correctly with all
the other devices. If you find another one
defective, follow the same steps until you find
all the problems.
B) START SYSTEMS:
1 • Disconnect all wires connected to the
START connector.
2 • If the LED turned OFF, try reconnecting one
device at a time until you find the defective
device.
NOTE:
In case procedures described in sections A)
and B) don’t result, remove control board and
send to our MOTORLINE technical services for
diagnosis.
. TROUBLESHOOTING
INSTRUCTIONS FOR FINAL CONSUMERS INSTRUCTIONS FOR TECHNICIANS
Table of contents
Other Motorline Controllers manuals
Popular Controllers manuals by other brands

Precision Digital Corporation
Precision Digital Corporation ProVu PD6210 instruction manual

Analog Technologies
Analog Technologies TEC50V20AB manual

YASKAWA
YASKAWA J1000 CIMR-JC series quick start guide

FLUENCE
FLUENCE SOLUNAR user guide

MosChip
MosChip MCS9901 user manual

Lenze
Lenze 530 series operating instructions