The PDV-6UK is a vertical power distributor which can be used in a wide variety of Sound Rack and/or
Projector Pedestal applications and areas.
This device offers a high level of protection & safety using class D circuit breakers. The PDV-6UK offers a
trip current of 10 to 20 times the rated current with an operating time of 0.04 to 3 Seconds. It is also used
for very high inductive loads.
The PDV-6UK is easy to connect and exible in transformation.
PACKAGE CONTENTS
1. PDV-6UK - 1 pcs
2. Cable Gland for cable dia 10-14 mm (0,39”-0,55”) - 1 pcs
3. Cable Gland for cable dia 13-18 mm (0,51”-0,71”) - 1 pcs
4. M6 rack screw pack - 4 pcs
5. Installation manual - 1 pcs
SAFETY INSTRUCTIONS
1. Do not use this equipment near water.
2. Only clean with a dry cloth.
3. Do not block any of the ventilation
openings. Install in accordance with the
manufacturer’s instructions.
4. Do not use near heat sources such as
stoves, heat registers, radiators or other
equipment (including ampliers) that
produces heat.
5. Do not use the unit near open re
sources.
6. Only connect the unit to the electric
network with grounding. Only use electric
plugs that provide grounding.
7. Protect the power cord from being
stepped on, pinched, or damaged in general.
8. Only use accessories specied by the
manufacturer.
9. Unplug the unit during lightning storms
or when unused for long periods of time.
10. Refer all servicing to qualied service
personnel. Servicing is required when the
system has been damaged in any way,
such as a damaged power supply cord or
plug, liquid has been spilled over or objects
have fallen into the unit, the unit has been
exposed to rain or moisture, the unit does
not operate normally, or has been dropped.
11. Indoor Use only.
12. WARNING - TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS SYSTEM UNIT TO RAIN OR MOISTURE.
SPECIFICATIONS:
Functions Power Supply Distributor
Power Input AC 32A 250V Tri-Phase
Input Сonnectors DIN rail Terminal Block
Output Сonnectors 6 х 16A UK Socket
Protection Сircuit Breaker 3 x D16A on 2 Sockets
IP Protection IP44
Rack Install 19” 3U
Dimensions 483 x 133 x 92 mm 19,02” x 5,24” x 3,63”
Shipping dimensions 500 x 150 x 100 mm 19,69” x 5,91” x 3,94”
Net weight 4,9 kg 10,80 lbs
Shipping weight 5,2 kg 11,46 lbs
OPTIONAL ACCESSORIES
1. Projector Pedestals PAP-Series
2. Sound Racks SR-Series
3. Sound Racks SRD-Series
PDV-6UK Power Supply
Distributor
www.mnmounting.com
[email protected]om
2 Merezhna str., Bila Tserkva,
Kyiv region, 09100, Ukraine
EMEA & Asian region:
+32 (0) 472 630212
USA, LATAM, Canada, Australia
& New Zealand region:
+1 (562) 607 7348
Dimensions
Cable input locations
Upon your convenience there’s multiple provided cable input locations to choose from. Cable
gland locations are provided on each of the ve sides of the unit.
PDV-6UK Power Supply
Distributor
www.mnmounting.com
[email protected]om
2 Merezhna str., Bila Tserkva,
Kyiv region, 09100, Ukraine
EMEA & Asian region:
+32 (0) 472 630212
USA, LATAM, Canada, Australia
& New Zealand region:
+1 (562) 607 7348
Possible Transformation
1. Rotating side mounts.
For ease of installation and best use of the power distributor, you can rotate its side plates 180
degrees. Simply unscrew the four screws, turn the plate and (re)tighten the screws.
2. Transfer of sockets to the front panel.
For the most convenient connection of the devices to the power distributor, install the sockets
on the front panel. To do this, unscrew the screws securing the panel with sockets, unscrew the
blank panel from the front side, transfer the panel with sockets to the front of the power distributor
(without disconnecting the cables from the sockets) and tighten with the screws. Install the blank
panel on the rear of the power distributor the same way.

Popular Power Distribution Unit manuals by other brands

Forza FPD-1611M0U user manual

Forza

Forza FPD-1611M0U user manual

AudioQuest NIAGARA 5000UK quick start guide

AudioQuest

AudioQuest NIAGARA 5000UK quick start guide

ABB SafeRing 36 Installation and operating instructions

ABB

ABB SafeRing 36 Installation and operating instructions

Altronix PDS8CB user manual

Altronix

Altronix PDS8CB user manual

BASE Electronics LV-8S Installation and operation manual

BASE Electronics

BASE Electronics LV-8S Installation and operation manual

ABB Relion 630 Series Operation manual

ABB

ABB Relion 630 Series Operation manual

Bachmann TOP FRAME Mounting instructions

Bachmann

Bachmann TOP FRAME Mounting instructions

hager univers N UC21LH0 Mounting instructions

hager

hager univers N UC21LH0 Mounting instructions

Pts PTS90423 Series installation guide

Pts

Pts PTS90423 Series installation guide

Vertiv Geist user manual

Vertiv

Vertiv Geist user manual

MuxLab VideoEase 500150 installation guide

MuxLab

MuxLab VideoEase 500150 installation guide

Server Technology switched pro2 user guide

Server Technology

Server Technology switched pro2 user guide

LEGRAND Mosaic 775 40 quick start guide

LEGRAND

LEGRAND Mosaic 775 40 quick start guide

Belkin PureAV PF30 user manual

Belkin

Belkin PureAV PF30 user manual

Amulex ESB030 user manual

Amulex

Amulex ESB030 user manual

Huawei PDU8000 Series Quick installation guide

Huawei

Huawei PDU8000 Series Quick installation guide

Eaton Remote Power Panel user guide

Eaton

Eaton Remote Power Panel user guide

Art 4x4 Series user manual

Art

Art 4x4 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.