mr. steam eTempo Plus User manual

MS Ar maFl ®A
Table f C ntents
Box Contents
................
2
Assembly and Installation
General Installation
.............
3
Installation of Hoses
.............
4
AssemblyDiagram ..................5
Electrical Wiring
...............
6
Sta
rt-up
Initial Priming of AromaSteam System
...
7
Filling the Pressure Hose
..........
7
Adjusting amount of oil delivery
....7
Troubleshooting
..............
8
Technical Information
..........
8
N TE:
It is strongly recommended that this warning sign (supplied)
be posted in a conspicuous location near the steam room.
Do not use with water soluble
fragrance or fragrance containing emulsifiers or aldehy-
des. AromaSteam system damage may result. Mr.Steam
oils are approved for operation with this system.
The use of any oils other than
Mr.Steam oils may introduce excessive concentration of
oil into the steam room, resulting in a health hazard.
Vapors may cause drowsiness and
dizziness. Keep out of the reach of children. In case of
contact with eyes, rinse immediately with plenty of
water and seek medical advice. If swallowed, rinse mouth
with water (only if the person is conscious), seek medical
advice immediately and show this container or label.
Highly Flammable. Keep away
from sources of ignition– No smoking. Keep container
tightly closed & in a well-ventilated place. This material
& its container must be disposed of as hazardous waste.
Not for use in acrylic or fiberglass
rooms.
Material Safety Data Sheet (MSDS) available upon request
WARNING
!
WARNING
!
WARNING
!
WARNING
!
signals a situation where minor injury or product
damage may occur if you do not follow instructions.
IMP RTANT N TE:
This highlights information that is especially relevant
to a problem-free installation.
IMP RTANT N TE:
As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient
installation and operation of this AromaSteam. These are two types of potential hazards that may occur during this installation and operation:
states a hazard which may cause serious injury
or death if precautions are not followed.
AromaSteam
(for illustrative purposes only)
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr.steam®
43-20 34th Street , Long Island City NY 11101
1 800 76 STEAM www.mrsteam.com
PU 100405
WARNING
!
Motor Operated
Pumps 24VW
mr.steam®aromasteam
Operation and Installation Instructions
_________________________________________________
WARNING
!
CAUTION
!
mr.steam®
Sussman-Automatic Corp®
www.mrsteam.com
43-20 34th Street
ong Island City, NY 11101
Tel: 1-800-76 STEAM
Fax: 718-472-3256
9410 S. a Cienega Blvd.
Inglewood CA 90301
1-800 -72 STEAM
Fax: 310-216-2944
WARNING
!
PUR 100402 - 6/08
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:24 AM Page 1

mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
B x C ntents
2
Shipping Hose
TABLE OF CONTENTS
Box Contents .................2
Assembly and Installation
General
. . . . . . . . . . . . . . . . . . . . . 3
Pump Assembly
. . . . . . . . . . . . . . . . . 4
Installation of Hoses
. . . . . . . . . . . . . . . 4
System Schematic
................5
Electrical Wiring
. . . . . . . . . . . . . . . . . 6
Assembly Diagram
................7
Start-up
Initial Priming of Metering Pump
. . . . . . . 8
Filling the Pressure Hose
............8
Programming Table
...............9
Maintenance
Maintenance of Metering Pump,
Suction Valve, and Pressure Valve
.......10
Troubleshooting. . . . . . . . . . . . . . . 11
Technical Information ..........11
Spare Parts . . . . . . . . . . . . . . . . . . 11
Warranty....................12
ADivision of Sussman-Automatic Corporation
43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500 • 1-800-767-8326 • Fax: (718) 472-3256 • www.mrsteam.com
Western Regional Offices
9410 S. La Cienega Blvd., Inglewood CA 90301 • 1-800 72 STEAM (1-800 727-8326) • Fax:(310) 216-2944
PUR 100402 - 01/06
NOTE:
Sussman-Automatic strongly recommends that this warning sign
(supplied) be posted in a conspicuous location near the steam room.
Do not use with water soluble fragrance or fragrance containing
emulsifiers or aldehydes. AromaStean pump damage may result.
MrSteam oils are approved for operation with this pump.
The use of any oils other than MrSteam oils may introduce excessive
concentration of oil into the steam room, resulting in a health hazard.
WARNING
!
WARNING
!
signals a situation where minor injury or product
dam-age may occur if you do not follow instructions.
IMPORTANT NOTE:
THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY
RELEVANT TOA PROBLEM-FREE INSTALLATION.
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of
this AromaSteam.These are two types of potential hazards that may occur during this installation and operation:
states a hazard which may cause serious injury
or death if precautions are not followed.
Fragrance Metering Pump
for Residential Steam Rooms
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
MrSteam
®
Commercial Steam Generators
Sussman-Automatic Corp. 43-20 34th Street , Long Island City NY 11101
1 800 76STEAM • www.mrsteam.com
WARNING
!
Listed Oil Delivery
Pump 24VW
mr.steamaromasteam®
operation and installation instructions
_________________________________________________
WARNING
!
CAUTION
!
AromaSteam System 6 ft. Pressure Hose 2 ft. Suction Hose with Filter
& Bracket Assembly
(with integrated 6 ft. power cord,
8 ft. request cable and 3 ft. demand cable)
1/2 inch NPT Atomizing Nozzle Injector with Injection Hose Scent Container Cap
Demand Button
(with integral 30 ft. cable)
Installation & Operation Manual
with Peel-off Warning abel
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:24 AM Page 2

The AromaSteam system is qualified for use with Mr.Steam residential steam generators NLY.
For use with residential steam rooms only. Not for commercial use.
1.
ocate the AromaSteam system to monitor the consumption of essential oils and for easy oil replacement.
2.
Mr.Steam strongly suggests that the warning sticker provided be placed in a conspicuous location near the
steam room.
3.
Mr.Steam AromaSteam System is designed and intended for indoor use only and is to be located indoors in a dry
clean location and not subject to moisture, condensation or similar high humidity environments.
4.
Do not install AromaSteam Systems outdoors.
5.
Do not install AromaSteam Systems in a location where water could freeze.
6.
Do not install AromaSteam Systems near flammable or corrosive materials and chemi-
cals. Installation in areas having high concentrations of chlorine (such as pool equip-
ment room) should be avoided.
7.
Attach the AromaSteam System onto a secure vertical surface.
8.
Provide access to AromaSteam System for servicing, and refills.
9.
The system should not be installed in areas accessible to children. A OCKED ROOM
IS STRONG Y RECOMMENDED (ie: utility room)
10.
Height difference between AromaSteam System discharge and 90 degree
Tis to be
held to a maximum
6 ft. (see page 5).
Clearance to heat sources
•
Do not install the AromaSteam system directly below or above the Mr. Steam steam
generator where it is subject to heat.
•
Minimum distance between the AromaSteam system and a heat source (e.g. steam
generator, heating system) is 1.5 ft. If this minimum distance of 1.5 ft cannot be
maintained, install a radiation plate or heat insulation between the heat source and
AromaSteam system.
•
Ambient temperature at and around the AromaSteam system should not exceed 90˚ F.
Installing the 90 degree T and Atomizing Nozzle
1.
For optimal results locate a brass 90 degree
T
(not provided) and atomizing nozzle
in the steam supply line between 16" and 36" from the steam head (see page 5). If
using copper tubing for steam lines, install a female 1/2 NPT thread to sweat fitting
in the downward facing
T.
2. T
must face downward as shown (in figure 2).
3.
Screw the atomizing nozzle into 90°
T
fitting using teflon tape on the threads.
Note:
The further the 90°
T
is from the steam head (more than 36”) the more the fra-
grance degrades and be less effective. Conversely, the closer the 90°
T
is to the steam-
head (less than 16”) the less the fragrance will "blend" with the steam and the aroma
effect will be lessen.
IMP RTANT N TE:
Follow the installation instructions for the steam
pipeline in the Mr.Steam Residential Steam Bath Installation and perating
Manual (PUR 101289). Visit www.mrsteam.com to download this document.
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
General Installati n
Steam ine
90˚ T
Figure 2
1/2 NPT
CAUTION
!
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr.steam®
43-20 34th Street , Long Island City NY 11101
1 800 76 STEAM www.mrsteam.com
PU 100405
WARNING
!
3
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:24 AM Page 3

mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
4
Installation of Pressure Hose to AromaSteam System.
1.
Unscrew the pressure end nut from the pump head and remove the shipping hose
and the pressure end nut.
2.
Insert the pressure hose through the hole of the pressure end nut and firmly push
the pressure hose onto the pressure valve.
3.
Screw the pressure end nut onto the pressure valve and tighten the nut by HAND only.
Installation of Suction Hose in Scent Container
1.
ocate the “container cap” in the AromaSteam box.
2.
Unscrew the cap from the Mr.Steam scent container and discard.
3.
Insert the suction hose with the open end from below through the hole in the
container cap (see Fig. 3).
4.
Insert the filter into the scent container so that the filter rests on the bottom.
5.
Screw the cap onto the scent container.
Installation of Suction Hose to AromaSteam System
1.
Unscrew the suction end nut from the pump head and remove shipping hose
(see Fig. 3) (discard shipping hose, keep pressure end nut).
2.
Remove suction end nut from the shipping hose.
3.
Insert the open end of the suction hose through the hole of the suction end nut.
4.
Firmly push the hose onto the cone of the suction valve at the pump head.
5.
Screw the suction end nut to the suction valve.
IMP RTANT N TE:
HAND-TIGHTEN ON Y.
Figure 4
Open End
Container Cap
Suction Hose
Filter
Container Height 8 inches
Suction Suction Pump Pressure Pressure
End Nut Valve Head Valve End Nut
Figure 3
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:24 AM Page 4

Typical Ar maSteam Installati n
F r use with
eTemp /Plus®C ntr ls
F r use with Temp ®,
Temp /Plus®and
eTemp ®C ntr lss
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
5
Pump ine Cord 120V
(grounded receptacle required)
eTempo/Plus
Typical Mr.Steam
Steam Generator
STEAM ROOM
UTI ITY
ROOM
Min. distance16"
Max. distance36"
Max ht.6 ft.
Cable to Steam Generator
(Request Cable) Steam Head
90˚ T
Atomizer Nozzle
Pressure Hose
Suction Hose
Scent Container
AromaSteam
Demand Button
Mounting
Bracket
AromaSteam
System
Steam ine
Pump ine Cord 120V
(grounded receptacle required)
Tempo,
Tempo/Plus
& eTempo
Typical Mr.Steam
Steam Generator
STEAM ROOM
UTI ITY
ROOM
Min. distance 16"
Max. distance 36"
Max ht.6 ft.
Cable to Steam Generator
(Request Cable) Steam Head
AromaSteam
Demand Button
90˚ T
Atomizer Nozzle
Pressure Hose
Suction Hose
Scent Container
Mounting
Bracket
AromaSteam
System
Steam ine
ocate the AromaSteam system to
monitor the consumption of essential
oils and for easy oil replacement.
NOTE:
CABLES SHOULD NOT CONTACT STEAM PIPE.
FO ILLUST ATIVE PU POSES ONLY
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:25 AM Page 5

mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
6
Contactor
Electrical C nnecti n f Ar maSteam™System
This AromaSteam system is factory
wired. If the power cord of the AromaSteam system is
damaged it must be replaced by the Sussman-Automatic
service department or similarly qualified personnel in
order to avoid risks. All electrical connections to be made
by a licensed, qualified electrician. Disconnect all power
to the steam generator before making power connec-
tions.
1.
Disconnect all power to the Mr Steam steambath gen-
erator and remove the top cover.
2. Run the request cable from the AromaSteam System
through one of the knockouts in the side of the
steambath generator. Use a strain relief bushing or
grommet to prevent chafing.
3. ocate the contactor inside the steambath generator
and identify the red and red/white wires. (NOTE:
Tempo generations use blue & white wires).
4. Remove those two wires from the contactor
and attach the request cable to those two
terminals.
5. Reconnect the red and red/white wires by attaching
them to the piggyback terminals on the request cable.
NOTE: When using generators hooked up in tandem the
AromaSteam steam system should be connected to the
contactor on the primary generator. The atomizing nozzle
should be connected to the main generator’s steam line.
Demand Butt n
ETEMPO/P US INSTA ATIONS:
1.
ocate the demand button on or near the pump brack-
et. The demand button will be used to turn on the
AromaSteam pump only during installation (and if
power is cut to the pump) as the AromaSteam pump is
controlled by the eTempo/Plus
TEMPO, TEMPO/P US AND ETEMPO INSTA ATIONS:
1.
ocate the demand button in a location accessible
to the steambather. Mr.Steam suggests adjacent to
the Tempo Controls.
2. A 7/8 inch hole is required for the demand button.
3. Fill the hole with silicone as required for a mois-
ture seal, care should be taken not to get silicone
on the adhesive on the back of the button.
CAUTION
!
Demand Button
(refer to Installation Instructions
for proper location)
AromaSteam
Plug Connector Connector
120 VAC
Outlet
(grounded receptacle required)
Request Cable
24 VAC to steam generator
(see below)
AromaSteam Wiring Schematic
Contactor
Contactor location in MS-65T- MS400T
and MS90E - MS400E
Contactor location in MSSUPER1T- MSSUPER6T
and MSSUPER1E- MSSUPER6E
Demand Cable
AromaSteam Connections when using
eTempo®Controls
For Tempo, Tempo/Plus, and eTempo
For Tempo, Tempo/Plus, and eTempo
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:25 AM Page 6

mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
7
Figure 5
Pressure Valve
Injector Hose
Figure 6
Push Button
AromaSteam
Metering Pump
Adjusting the Am unt
f Oil Delivery
The AromaSteam system has been factory set to deliver a
suitable amount of aromatic oil into a typical sized steam room. PLEASE CONTACT
THE M STEAM TECHNICAL SE VICE DEPA TMENT BEFO E CHANGING THIS SETTING.
Increasing the settings may introduce excessive concentration of oil into the
steam room, resulting in a health hazard.
Contact the MrSteam Technical Service Department at (800) 76-STEAM (East
coast) or (800) 72-STEAM (West coast)
for assistance or additional information.
Only a qualified licensed electrician or factory authorized
personnel may adjsut the factory setting.
WARNING
!
WARNING
!
Operati n
ETEMPO/P US
1.
Press the AROMA button on the eTempo/Plus
control (Aroma will appear in the display).
2
. When the generator is steaming the pump will inject oil into the
steam line at preset time intervals.
3
. If the generator is not steaming, no oil will be pumped.
TEMPO, TEMPO/P US AND ETEMPO
1.
With the generator on press the demand button once
(the demand button will light up).
2
. When the generator is steaming the pump will inject oil into the
steam line at preset time intervals.
3
. If the generator is not steaming, no oil will be pumped.
Note:
After the generator has been turned off the light on the
demand button will remain ON, the pump will be in stand-by mode
waiting for the generator to be turned on again.
Start-up
Initial Priming of the Pump
1. Insure MrSteam scent container is full.
2. Insert the short injector hose onto the tip of the injector
(see Fig. 5).
3. Unscrew the pressure end nut from the pump head and remove the
pressure hose from the pressure valve (see Fig.3).
4. Insert the open end of the injection hose onto the pressure valve
(see Fig. 5).
5. Draw liquid from the injector slowly and evenly. Continue until the
injector is full of liquid.
6. If you have drawn up the injector completely and no liquid is in the
injector, remove the injector hose from the pressure valve.
7. Drain injector. Repeat steps until the injector is filled.
8. Save the oil injector as it will be needed when new oils are used.
Filling the Pressure Hose
1.
Insure the AromaSteam System is primed and the scent container
is full.
2
. ocate the Push-button at the rear of the metering pump (see
Fig. 6). Depress this push-button to start metering pump.
3.
Continue to depress push-button until the pressure hose is filled
with liquid.
IMP RTANT N TE:
Push button to be used only for initial filling
of the pressure hose, and after new oil bottles are installed.
Aroma button
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:25 AM Page 7

MR.STEAM and des., A IFETIME OF P EASURE, A EGRO, AROMAF O, AUTOF USH, C EAN STEAM...EVER TIME, MRSAUNA, STEAM ON DEMAND, STEAM@HOME,
SUSSMAN, SUSSMAN IFESTY E GROUP, TEMPO, TEMPO/P US, TEMPO/REMOTE, TEMPO/EXT, WARMATOWE , eTEMPO, eTEMPO/P US, eTEMPO/REMOTE,
eTEMPO/START and STEAMTHERAPY, are registered trademarks of Sussman-Automatic Corporation. AROMASTEAM, C UB THERAPY, CHROMASTEAM, F1 P US,
MUSICTHERAPY, SAUNA/ONE, MAKE WE NESS a WAY of IFE and FROM BATHROOM TO SPA are trademarks of Sussman-Automatic Corporation.
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
8
Tr ublesh ting
TO AVOID E ECTRIC SHOCK, DISCONNECT POWER TO PUMP BEFORE SERVICING
METERING PUMP D ES N T PRIME
1.
Check if voltage is available.
2.
Check liquid level in scent container. Replenish liquid, if necessary.
3.
Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.
4.
Check valves for contamination. Clean valves, if necessary.
5.
Check filter in container for contamination. Rinse filter under clean water.
Metering pump does not inject oil into steam room
1.
Check if voltage is available.
2.
Check liquid level in scent container. Replenish liquid, if necessary.
3.
Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.
4.
Check valves for contamination. Clean valves, if necessary.
5.
Check filter in container for contamination. Rinse filter under clean water.
6.
Check the pressure hose for kinking or jamming. Straighten or replace.
7.
Check if liquid is freely flowing through the atomizing nozzle when the metering pump is energized. Apply compressed air through the atomizing
nozzle. Attach the compressed air at the point of connection of the pressure hose.
8.
For eTempo/Plus: ensure the demand button light is on. the demand button light should be pressed during installation, the light willl turn on. In
the event of a power outage the button will need to be pressed again.
Metering pump oil delivery too much or too little
Contact Mr.Steam techincal service personnel at 1-800-76 STEAM (East Coast) or 1-800-72-STEAM (West Coast).
Technical Specificati ns
Dimensions: 7” L x 6.5” W x 4.5” H
___________________________________________
Weight: 5pounds
___________________________________________
EN 60335
U isted
CSA Approved
___________________________________________
Motor voltage 120 VAC, 50/60 Hz
Power consumption, total [W] 12 Watt
List of Spare Parts
Description Part No.
Pump Head 103861
Pressure/Suction Hose EO1-1032
(ordered by the foot)
Eucalyptus oil, 1 liter MS OIL 1
avender oil, 1 liter MS OIL 2
Evergreen oil, 1 liter MS OIL 3
Energizing Mint oil, 1 liter MS OIL 4
Poho oil, 1 liter MS OIL 5
Atomizing Nozzle 103918
Oil Injector 103983
Filter 103987
WARNING
!
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:25 AM Page 8
Table of contents
Other mr. steam Portable Generator manuals

mr. steam
mr. steam Feel Good Steam Home SAH3000 Instruction manual

mr. steam
mr. steam CU-360 Instruction manual

mr. steam
mr. steam CU-4500 Instruction manual

mr. steam
mr. steam CT6E Owner's manual

mr. steam
mr. steam MS-90E User manual

mr. steam
mr. steam CT9E Instruction manual

mr. steam
mr. steam CU-360 Instruction manual

mr. steam
mr. steam CT6E Instruction manual

mr. steam
mr. steam MX6E User manual