Page 4 of 6 microStar 032021-V1
Fail-Safe:
oWhen enabled, the fail-safe function causes the output relay to energize as soon as the sensor is
powered on. The relay will then de-energize when the sensor is activated or when there is a power loss.
In this manner, a power loss causes the relay output to perform the same as if there was a detection. If
fail-safe is disabled, the relay remains de-energized when power is applied and will only energize upon
an activation.
HPR:
oWhen the Human Presence Radar is enabled, the sensitivity of the radar is increased to allow detection
of extremely slow movements within the field of detection.
Depart/Approach:
oWhen configured for DEPART, the sensor will only detect activity that is moving away from the sensor. In
APPROACH mode, the sensor will only see activity that is approaching the sensor.
Bi-Directional / Uni-Directional:
oThe Bi-Directional function allows the sensor to see movements from all directions within its detection
zone. In Uni-Directional mode, the sensor only detects movements that are towards the sensor.
WIRING
① Wire the sensor according to the application and plug the harness into the sensor upon completion. Wire
connections are shown below.
POWER-ON
① Upon completion of the mechanical installation, configuring the sensor, and all necessary wiring, apply voltage to
the sensor (12 to 24 volts AC or DC).
The LED located at the lower left side of the antenna will illuminate green when the sensor is ready for use.