13
14.6V(default) 29.2V(default)
Floatingcharge 13.4V(default) 26.8V(default)
Equalizationcharge 14.0V(default) 28.0V(default)
Over chargedisconnection 14.8V 29.6V
Over chargerecovery 13.6V 27.2V
Over dischargedisconnection 10.8V
(default) 21.6V(default)
Over dischargereconnection 12.3V 24.6V
Temperaturecompensation -13.2mV/ -26.4mV/
Leadacidbatterysettings Adjustable
NiCad batterysettings Adjustable
Load control mode
1.Low Voltage Reconnect (LVR): Adjustable
2.Low Voltage Disconnect (LVD): Automatic disconnection
3.Reconnection: Includes warning flash before
disconnect and reconnection
Low voltagereconnect 12.0-14.0 Vdc 24.0-28.0 Vdc
Low voltagedisconnect 10.5-12.5 Vdc 21.0-25.0 Vdc
Ambient temperature 0-40 (full load) 40 60 (de-rating)
Altitude Operating5000m, Non-Operating 16000m
Protectionclass IP21
Battery temperature sensor
BTS -optional remote battery temperat
Ure sensor for increased charging precision
Terminalsize(fine/singlewire) #8 AWG
O
Table 1 Electrical specifications@(77 F)
RatedVoltage
Rated chargecurrent
Loadcurrent
Input voltagerange
Max. PV open circuit
array voltage
Typicalidle consumption
Overload protection (DC load)
12/24V DC
40A
15A
15-55V DC
55V DC
At idle < 10mA
2.0*Inom>5s
1.5*Inom >20s
1.25*Inom temperature controlled
Solar changer function
There is a solar charger built in, List below is the spec for solar charger
NOTE:The optional battery temperature sensor automatically adjusts the charging process of the
controller according to the type of the battery is selected by user through battery type selector.
With the battery temperature sensor installed, the controller will increase or decrease the
battery charging voltage depending on the temperature of the battery to optimizethe charge
to the battery and maintain optional performance of the battery.
chargeBulk
C C