not
Fig.1
e b
2) Multiple batteries in series connection(Refer to Fig.3):The sum of their voltages must be equal to the Nominal
DC Voltage of the unit.All batteries must be equal in voltage and amp hour capacity.
Step4: Install a DC Breaker in a positive line. The rating of the DC Breaker must be according to the inverter’s
battery current (75Amp). Keep the DC Breaker off.(See Fig.2)
Step5: Connect battery cable to the external batteries.
Note: For the user operation safety, we strongly recommend that you should use tapes to isolate the battery
terminals before you start to operate the unit.
1) Single battery connedion (Refer to Fig.2) : When using a single battery, its voltage must be equal to the Nominal
DC Voltage of the unit.(See below Table 1)
Input frequency/Output frequency
Input frequency 0Hz Output =5 frequency=50Hz
Input Output voltage=230V voltage=230V
Battery Output voltage=25.5V voltage=230V
Battery voltage/ voltageOutput
Battery voltage/Load percentage
Battery voltage=25.5V Load percentage=70%
The LCD display information will be switched in turns by pressing "UP or DOWN” key.The selectable information
is switched as below order: input voltage, output voltage,input frequency, output frequency, PV voltage,PV
power,charging current,PV power,battery voltage,output voltage, load percentage, load in Watt,CPU version.
Battery voltage/Load in Watt