OPERATION MANUAL
2015.01.20 0001 ה
Thank you for purchasing BOX for Control Panel E4000 - PB. This " BOX for Control Panel "
is designed for can be attach the Control Panel. Read this and Control Panel Extension
Cord Operation Manuals carefully before use. Always keep this Operation Manual in a
place where a user can referred to for reference at any time.
BOX for Control Panel
E4000 - PB
1 - 1 Specifications
Product Name BOX for Control Panel
Model E4000 - PB
Applicable Products E4000 Control Panel, E4000 Control Panel Extension Cord
Weight 216g
Standard Accessories
・Mounting Screw (M3) ・・6pcs.
・Blind Plate ・・1pc.
・Mounting Screw (M4) ・・2pcs.
・Operation Manual ・・1set.
1 - 2 Standard Accessories
Confirm the following Accessories after opened the Packing Box.
Case A Case B
Blind Plate
Mounting Screw (M4)
Mounting Screw (M3)
Mounting Screw (M4)
Mounting Screw (M3)
Fig. 1
1 - 3 Outside View
88 25 1.2 120
88
135
2-
ȭ4.5
CAUTION
Be sure to read and understand the Control Panel Extension Cord Operation
Manual before installation.
①Attach the Control Panel to the Case A by using the Mounting Screw (M3 : Standard
Accessories) 4 positions (Fig. 6).
Fig. 5
Case A Control Panel
: Mounting
Screw (M3)
Fig. 6
②Connect the connector of the
Control Panel Extension Cord to
the connector of the Control Panel.
Connector
Fig. 7
③Mount the Case B to the Case A
by using Mounting Screw (M3 :
Standard Accessories) 4 positions.
: Mounting
Screw (M3)
Case B
Case A
Fig. 8
3.
INSTALLATION OF THE BOX FOR CONTROL PANEL
3 - 1 Rear Mounting
1. SPECIFICATIONS AND DIMENSIONS
①Mount the Blind Plate to Case B by using Mounting Screw (M3 : Standard Accessories)
2 positions.
②Mount the Blind Plate to the Installation location by using Mounting Screw (M4 :
Standard Accessories) 2 positions.
Blind Plate
: Mounting Screw (M3): Mounting Screw (M3)
Fig. 9
: Mounting Screw (M4): Mounting Screw (M4)
Fig. 10
3 - 2 Bottom Mounting
Blind Plate
: Mounting Screw (M3)
Fig. 11
: Mounting Screw (M4)
Fig. 12
①Mount the Blind Plate to bottom of the Case A by using Mounting Screw (M3 :
Standard Accessories) 2 positions.
②Mount the Blind Plate to the Installation location by using Mounting Screw (M4 :
Standard Accessories) 2 positions.
①Rear Mounting
②Bottom Mounting
③Tapping Mounting
25
135
120
88
88
1.2
2-ȭ4.5
2-M3x0.5
25 70
70
88
88
44
12.5
2-M3x0.5
Fig. 2
Fig. 3
Fig. 4
2.
INSTALLATION OF THE CONTROL PANEL AND BOX FOR CONTROL PANEL
WARNING
・Turn OFF the Main Power Switch of the CONTROLLER before Control
Panel Extension Cord mounting.
・When attaching the Control Panel, protect the Control Panel from oil and
other contaminants.
・Take care when selecting routing of cord of Control Panel to insure that
the cord is not routed near potential sources of RF noise.
・Attach the Control Panel in manner to insure that the back of the circuit
board of the Control Panel does not contact any object or surface that
could cause potential short circuit.
4. DISPOSAL OF THIS PRODUCTS
When disposal of E4000 - PB is necessary, follow the instructions from your local
government agency for proper disposal of electrical components .
Temperature Humidity Atmospheric
Pressure
Operation Environment
0 - 40°CMAX.75%
(No condensation)
700 - 1,060hPa
Transportation and
Storage Environment
-10 - + 50°C 10 - 85% 500 - 1,060hPa