manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NAPCO
  6. •
  7. Control Panel
  8. •
  9. NAPCO Gemini GEM-P1664EX User manual

NAPCO Gemini GEM-P1664EX User manual

Other manuals for Gemini GEM-P1664EX

2

This manual suits for next models

3

Other NAPCO Control Panel manuals

NAPCO Gemini GEM-P3200 User manual

NAPCO

NAPCO Gemini GEM-P3200 User manual

NAPCO Magnum Alert 2600 User manual

NAPCO

NAPCO Magnum Alert 2600 User manual

NAPCO Magnum Alert 2600 User manual

NAPCO

NAPCO Magnum Alert 2600 User manual

NAPCO Gemini GEM-P9600 Installation manual

NAPCO

NAPCO Gemini GEM-P9600 Installation manual

NAPCO Freedom F-64 Installation manual

NAPCO

NAPCO Freedom F-64 Installation manual

NAPCO Gemini GEM-P816 Installation manual

NAPCO

NAPCO Gemini GEM-P816 Installation manual

NAPCO Gemini GEM-P1632 User manual

NAPCO

NAPCO Gemini GEM-P1632 User manual

NAPCO XP-400 User manual

NAPCO

NAPCO XP-400 User manual

NAPCO Gemini GEM-P1664EX Installation manual

NAPCO

NAPCO Gemini GEM-P1664EX Installation manual

NAPCO Gemini GEM-P1632 Installation manual

NAPCO

NAPCO Gemini GEM-P1632 Installation manual

NAPCO Magnum Alert 2600 Product guide

NAPCO

NAPCO Magnum Alert 2600 Product guide

NAPCO GEMINI GEMC-255 User manual

NAPCO

NAPCO GEMINI GEMC-255 User manual

NAPCO Gemini GEM-P3200 Installation manual

NAPCO

NAPCO Gemini GEM-P3200 Installation manual

NAPCO XP-400 User manual

NAPCO

NAPCO XP-400 User manual

NAPCO Magnum Alert 1008 series User manual

NAPCO

NAPCO Magnum Alert 1008 series User manual

NAPCO GEM-P800 User manual

NAPCO

NAPCO GEM-P800 User manual

NAPCO Gemini GEM-P3200 Installation and operating instructions

NAPCO

NAPCO Gemini GEM-P3200 Installation and operating instructions

NAPCO GEM-P800 User manual

NAPCO

NAPCO GEM-P800 User manual

NAPCO Gemini GEM-P3200 User manual

NAPCO

NAPCO Gemini GEM-P3200 User manual

NAPCO X 255 - Installation manual

NAPCO

NAPCO X 255 - Installation manual

NAPCO Gemini GEM-P9600 User manual

NAPCO

NAPCO Gemini GEM-P9600 User manual

NAPCO MA3000 Technical specifications

NAPCO

NAPCO MA3000 Technical specifications

NAPCO Gemini GEM-P1664EX Installation manual

NAPCO

NAPCO Gemini GEM-P1664EX Installation manual

NAPCO Gemini GEM-P3200 User manual

NAPCO

NAPCO Gemini GEM-P3200 User manual

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

Fagor 8040 TCO CNC operating manual

Fagor

Fagor 8040 TCO CNC operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

GEM-P1664 Series:
8 to 64 Zone Hybrid Hardwire/Wireless Controls
Suitable for EN50131-1 Installations
The GEM-P1664 Series hardwire/
wireless control panel with
partitioning ideal to standardize
on for both residential &
commercial applications!
Features:
•8 to 64 hardwire/wireless zones (including two 2-wire fire
zones)
•Programmable partitioning for up to four areas
•Up to 64 users
•Supports full range of reliable NAPCO Wireless crystal-
control transmitters– proven to outperform leading
competitive brands in independent tests!
•Choice of custom alphanumeric, digital and icon keypads
•Temperature display on keypad (with optional
temperature sensor), shown at left.
Two configurations for every application requirement:
• GEM-P1664EX model suitable for use in EN50131-1
Installations (wall mount transformer not included).
• GEM-P1664EX-230 model suitable for use in
EN50131-1 CE installations. Unit is CE marked and
includes internally mounted 230V transformer.
NAPCO manufacturing ensures product quality and is ISO9001: 2000 certified
The GEM-P1664 Hybrid 8 to 64-Zone Control/
Communicator features 8 zones expandable
to 64 zones with multiplexing and supports
proven, reliable, NAPCO crystal-control
transmitters and uses advanced helically-filtered
receivers, too. Supporting up to 64 user codes
and 8 16 relays, the GEM-P1664 comes in two
configurations suitable for EN50131-1 and/or
CE installations. This Gem control features easy
“Self-Programming Plus” keypad programming
(for all zones), which includes new alpha
keypad question-prompts, even for setting test
timer, fire zones and exit/entry and follower
zones. Additionally, the panel can be remote
up/downloaded using easy-to-use NAPCO
Quickloader Software (V5.0 or greater) with true
Windows-style functionality, including cut/paste,
drop/drag, etc.
FEATURES
•8 Hardwire/Wireless Zones on board
•Up to 64 zones with multiplex expansion
including 2 two 2-wire fire zones
•With multiplexing, can accommodate up to
64 EOL zones (from custom alpha keypads or
multiplex modules)
•EZ Programming2 More comprehensive,
menu-driven programming for all zones plus
test timer.
•Up to 64 user codes
•Up to 4 areas
•3 on-board outputs, up to16 external relay
outputs (RM3008s).
•Up to 2 NAPCO helically-filtered, crystal-
control RF receivers
•Interior bypass group with programmable
automatic interior bypass
•600 event log
•Auto Arm
•Uses up to 7 of any of the Classic/RP- or K-
Series Stay & Away keypads
•Programmable telephone line cut supervision
with delay
•3 Keypad panics (F, P, A)
•Supports all major communicator formats,
including: 4/2, SIA, 4+2 and Point ID, plus
pager
•Backup/double/split reporting; three 20-digit
telephone numbers
•Dynamic battery test
•Reports alarms, restores and troubles by zone.
•2 programmable entry delay times
•Chime by zone
•8 EOL burglary zones programmable for area,
E/E delay, interior, follower, day zone, chime,
fire options, sensor watch, swinger shutdown,
cross zoning , etc.
•Supports series zone doubling and Loop
supervision using double EOL resistors
(feature requires use of GEM-EZM4/8
Multiplex Modules)
•Multiplex Expandability with GEM EZM4/8 or
GEM EZM8 zone expansion modules
•Quickloader up/downloading, including
unique unattended method
•Choice of RF receivers
•Partitioning by area
•Event log with open/close suppression
•Event log viewable at keypad (total log,
burglar alarm log, fire alarm log, system
trouble log, o/c log)
•Cellphone-style keypad programming of zone
descriptions ( text)
•Programmable 50Hz Clock Setting
•Programmable Daylight Savings Time
•Programmable Security Bypass (code required
for bypass)
•Un-Bypassing while disarmed (code required)
•Temperature Display at Keypad (-30 to 600C
Celsius or -22 to 1400F Fahrenheit) with
optional GEM-TEMP64 Indoor/Outdoor
Temperature Sensor (Note: Keypad
Temperature Display replaces Date on Display)
•Programmable High/Low Temperature Alarm
Reporting (requires feature enabled; zone 6)
•24 Hour day zone trouble
•Programmable security blocking of keypad
display messages –Informational displays
made visible contingent on user’s assigned
area(s) within system
•Programmable Swinger Shutdown (2 or 3
activations – selectable)
•Zone Anding/Cross Zoning (Grouping of zones
in which sequential zone activation is required
to generate an alarm)
SPECIFICATIONS
•Environmental Classification: Class I (+5C to +40C),
Class II (-10C to +40C) and Class III (-25C to +50C)
•Input power: 16.5VAC via Class 2 plug-in 20VA, 40VA
or 50VA transformer
•Loop voltage: 10-13VDCdc
•Loop current: 32.5mA with 2.2k ohm EOLR; 5mA for
2-wire fire
•Loop resistance: 300 ohm max.; 50 ohm max for
2-wire fire
•Aux & remote power: 12VDC regulated (11.7 to
12.5VDC)
•Maximum Combined standby current: 650mA
•Maximum Alarm current: 2A
•Burg. voltage output: 1
•Programmable negative outputs: 2
•Loop response 750ms, programmable 50ms to
2,000ms
POWER (With Type A Power Supply):
Grades 1 and 2 Installations with 4AH battery:
Maximum combined standby current: 210mA
Maximum combined standby current and alarm current:
650mA
Grades 1 and 2 installations with 7AHbattery:
Maximum combined standby current is: 460mA
Maximum combined standby current and alarm current:
500mA
Grade 3 installations (requires 7AH battery):
Maximum combined standby current is : 110mA
Maximum combined standby current and alarm current:
500mA
ORDERING INFORMATION
GEM-P1664EX Control Panel suitable for use
in EN50131-1 Installations (transformer not
supplied).
GEM-P1664EX-230 Control panel, as above,
prewired with transformer (included) suitable for
use in EN50131-1 CE installations., CE marked.
PCD2000 NAPCO QUICKLOADER®Up/
Downloading Software For panel programming,
requires version 5.0 or greater. (Windows-
based).
GEM-RP1CAe2 Deluxe Custom Alphanumeric
Dual-Line Display Keypad with built in 4-Zone
Expansion Module. Classic NAPCO user
functionality. (New Black and White Decorator
Styling). (Firmware Version 9A+)
GEM-K1CA, as above, with STAY and AWAY
user functionality. (Firmware Version 9A+)
GEM-TEMP64 Optional temperature sensor,
for use with either of the two keypads above,
programmable for celsius or fahrenheit. Indoor
or outdoor temperature display at keypad.
GEM-RP2ASe2 Alpha/Icon Keypad (Version 7
firmware+ support required).
GEM-K2AS, as above, with STAY and AWAY
user functionality. (Version 7 firmware+ support
required).
GEM-RP3DGTL Digital Keypad (Version 3
firmware+ support required).
GEM-K3DGTL, as above, with STAY and AWAY
user functionality. (Version 3 firmware+ support
required).
GEM-EZM4/8 Mulitplex Module for 4 to 8 zones
expansion (supports series zone doubling and
loop supervision using double EOL resistors).
GEM-EZM8 8-Zone Mulitplex Module
Choice of NAPCO Wireless Receivers & Full
Range of NAPCO GEM or Libra Wireless
Transmitters (consult manual for selection for
your region’s frequency):
GEM-K4RF Fixed English Language Display
Keypad with 32Pt. Built-in Wireless Receiver
(Version 2 firmware+).
GEM-K4RF-SPAN Spanish Language version of
above. Note: Other language versions, also available:
Call NAPCO International Sales for info.
LIBRA RECV255-433 255 point receiver
LIBRA RECV8-433 8 point receiver
LIBRA-REC16433 Wireless 16 Point Receiver
LIBRAREC96433 Wireless 96 Point Receiver
LIBRA-TRANS433 Wireless Door Contact
LIBRA-PIR433 Wireless PIR
LIBRA-KEYF433 Wireless KeyFob
LIBRA-SMK433 Wireless Smoke Detector
LIBRA-GB433 Wireless Glass Break Sensor
GEM-RECV255 Wireless Receiver, 96 Zones
GEM-RECV96 Wireless Receiver, 96 Zones
GEM-RECV16 Wireless Receiver, 16 Zones
GEM-RECV8 Wireless Receiver, 8 Zones
GEM-TRANS2 Window/Door Transmitter, 2-Pt
GEM-RTRANS Recessed Window/Door
Transmitter
GEM-KEYF Key Fob Transmitter
GEM-SMK Wireless Smoke Detector
GEM-PIR Wireless PIR
GEM-PIRPET Wireless Pet Immune Transmitter
GEM-DT Wireless Dual-Technology Sensor
GEM-GB Wireless Glass-Break Detector
WI1388 Instruction/Programming Manual
WI1386 Instruction/Programming Manual with
RP1/K1 Keypads
WI1418 GEM-EZM4/8 Zone Expansion with
GEM-P1664 Control
333 Bayview Ave., Amityville, NY, USA 11701
+1.631.842.9400 •+1 (631) 842-2382 fax
www.napcosecurity.com
NASDAQ: NSSC
email: 4-intl-sales@napcosecurity.com
A497 © NAPCO, 6/05
Preliminary specifications subject to change.
GEM-P1664 zone hybrid control