4
W415-0663 / B / 02.21.08
Do not use abrasive
cleaners to clean plated
parts. Buff lightly with a
clean dry cloth.
DO NOT SUBSTITUTE
MATERIALS. Clean the glass after the first 10 hours of operation with a
recommended gas fireplace glass cleaner. Thereafter clean as required.
DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent
discolouration and / or blemishes may result.
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes.
Installation practices vary from region to region and it is important to know the specifics that apply to your area,
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.
• A carbon monoxide detector is required in all rooms containing gas fired appliances.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
• WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
A manuafactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety
Standard, title 24CFR, part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/
NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig
(3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile or other combustible material
other than wood flooring, the fireplace shall be installed on a metal or wood panel extending
the full width and depth.
If the optional blower is installed, the receptacle / junction box must be electrically connected
and grounded in accordance with local codes. In the absence of local codes, use the current
CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
GENERAL INSTRUCTIONS
GENERAL INFORMATION
CARE OF GLASS AND PLATED PARTS
GD34-1 GLASS TYPE BGD34-1 GLASS TYPE
3/16" Ceramic Glass* 3/16" Tempered Glass*
*Available from your Napoleon®/ Wolf Steel Ltd. dealer.
This fireplace is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Provide adequate circulation air. Provide adequate accessibility clearance for servicing and operating the fireplace. Never obstruct
the front opening of the fireplace.
Objects placed in front of the fireplace must be kept at a minimum of 48" from the front face of the unit.
Use only Napoleon® accessories designed for and listed with the model.
GD34-1 RATES AND EFFICIENCIES BGD34-1 RATES AND EFFICIENCIES
NG LP NG LP
ALTITUDE (FT) 0 - 4,500 0 - 4,500 ALTITUDE (FT) 0 - 4,500 0 - 4,500
MAX. INPUT (BTU/HR) 22,000 22,000 MAX. INPUT (BTU/HR) 15,000 15,000
MAX. OUTPUT (BTU/HR) 18,040 18,040 MAX. OUTPUT (BTU/HR) 11,700 11,700
MAX. EFFICIENCY (w/ the fan on) 82% 82% MAX. EFFICIENCY (w/ the fan on) 78% 78%
MINIMUM INLET GAS SUPPLY
PRESSURE
4.5" WATER
COLUMN
11" WATER
COLUMN
MINIMUM INLET GAS SUPPLY
PRESSURE
4.5" WATER
COLUMN
11" WATER
COLUMN
MAXIMUM INLET GAS SUPPLY
PRESSURE
7" WATER
COLUMN
13" WATER
COLUMN
MAXIMUM INLET GAS SUPPLY
PRESSURE
7" WATER
COLUMN
13" WATER
COLUMN
MANIFOLD PRESSURE
(under flow conditions)
3.5" WATER
COLUMN
10" WATER
COLUMN
MANIFOLD PRESSURE
(under flow conditions)
3.5" WATER
COLUMN
10" WATER
COLUMN